• Title/Summary/Keyword: 열형광

Search Result 323, Processing Time 0.022 seconds

Evaluation of dose variation at the vertex during Total Skin Electron Beam (전신 피부 전자선 조사(TSEB)시 두정부(Vertex)에서의 선량 변화 평가)

  • Jeon Byeong-Chul;An Seung-Kwon;Lee Sang-Gyu;Kim Joo-Ho;Cho Kwang-Hwan;Cho Jung-Hee;Park Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.112-116
    • /
    • 2000
  • Purpose : The vertex scalp is always tangentially irradiated during total skin electron beam(TSEB) This study was discuss to the dose distribution at the vertex scalp and to evaluate the use of an electron reflector. positioned above the head as a means of improving the dose uniformity. Methods and Materials Vetex dosimetry was performed using ion-chamber and TLD. Measurements were 6 MeV electron beam obtained by placing an acrylic beam speller in the beam line. Studies were performed to investigate the effect of electron scattering on vertex dose when a lead reflector $40{\times}40cm$ in area, was positioned above the phantom. Results : The surface dose at the vertex, in the without of the reflector was found to be less than $37.8\%$ of the skin dose. Use of the lead reflector increased this value to $62.2\%$ for the 6 MeV beam. Conclusion : The vertex may be significantly under-dosed using standard techniques for total skin electron beam. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation.

  • PDF

The Feasibility Study of photoconductor materials for the use of a dosimeter in Radiotherapy (광도전체 물질의 치료 방사선 선량계 적용을 위한 가능성 연구)

  • Jang, Giwon;Shin, Jungwook;Oh, Kyungmin;Park, Sungkwang;Kim, Jinyoung;Park, Jikoon;Nam, Sanghee
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.81-84
    • /
    • 2013
  • The use of the dosimetry have been increasingly recognized as high radiation energy and radiation treatment planning(RTP) have rapidly developed in radiotherapy. There are many types of detectors for the dosimetry such as ionization chamber, film, TLD, diode, and etc. Among such detectors, the diode detector uses a photoconductor materials that generate electrical signals by the incident radiation energy. Though many research groups are recently interested in such materials, there is few experimental results except for silicon in the radiation therapy field. In this study, the feasibility of photoconductor materials was verified as a dosimeter through the evaluation of response properties at a high radiation energy. For the fabricated detectors based on $HgI_2$ and $PbI_2$, reproducibility, linearity, and pulse-rate response were analyzed. Such evaluations are essential factors for the use of dosimeter. From results, linearity and reproducibility of the fabricated $HgI_2$ detector indicated about 7% error. The fabricated $PbI_2$ detector showed 1.7% error in linearity, and 12.2% error in reproducibility.

Characterization of Natural Zeolite for Removal of Radioactive Nuclides (방사성 핵종 제거를 위한 천연 제올라이트 특성 연구)

  • Kim, Hu Sik;Park, Won Kwang;Lee, Ha Young;Park, Jong Sam;Lim, Woo Taik
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.41-51
    • /
    • 2014
  • The four natural zeolites collected in Pohang and Gyeongju area, Kyungsangbuk-do, Korea, were characterized by XRD, XRF, DTA, TGA, and CEC analysis. The primary species of these zeolite are heulandite, modenite, illite, and illite in Kuryongpo (Ku), Pohang (Po), Yangbuk-A (Ya-A), and Yangbuk-B (Ya-B) samples. The XRF analysis showed that the four zeolites contain Si, Al, Na, K, Mg, Ca, and Fe. Cation exchange capacity of Kuryongpo (Ku) zeolite was the highest compared to other zeolites. The adsorption capacities of Cs and Sr in the four natural zeolites were compared at $25^{\circ}C$. On the basis of adsorption data Langmuir and Freundlich adsorption isotherm model were confirmed. The equilibrium process was descried well by Langmuir isotherm model. This study shows that Ya-A zeolite is the most efficient for the $Cs^+$ and $Sr^{2+}$ ion adsorption compared to the other natural zeolites.

Material Characteristics of White Wares from Yeongdong Province, Gangwon-do: Gangneung and Donghae Kiln Sites (강원 영동지역 백자의 재료과학적 특성 연구: 강릉 남양리 백자가마터와 동해 발한동2(사문동) 가마터를 중심으로)

  • Lee, Byeong Hoon;So, Myoung-Gi
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.181-192
    • /
    • 2015
  • This study aims to examine production technique of twelve white wares from the Gangneung Namyang-ri and Donghae Balhan-dong2(Samun-dong) kiln sites, Kangwon Province and characteristics of the used materials, and to find a correlation among materials of the excavated white wares. X-ray fluorescence sequential spectroscopy(XRF), X-ray diffraction(XRD), Dilatometer and Inductively coupled plasma mass spectrometry(ICP-MS), Inductively coupled plasma automic emission spectrometer(ICP-AES) were applied to determine the chemical composition, crystalline phase of samples, firing temperatures, trace elements and rare earth elements. When analyzing body crystalline phases of the white wares using the XRD method, quartz and mullite were extracted from all the samples. Though firing temperature of each sample was different, they were mostly fired at a temperature below $1200^{\circ}C$. Analyzing the excavated white wares using the Seger formula, compositional properties of white wares in Gangneung Namyang-ri kiln showed diffrently from the Donghae Balhan-dong2(Samun-dong) kiln. The body of white wares from Gangneung Namyang-ri kiln have higher raito of $RO_2$ and $RO+R_2O$ than of white wares from Donghae Balhan-dong2(Samun-dong) kiln site. The white wares from Gangneung Namyang-ri kiln and Donghae Balhan-dong2(Samun-dong) kiln were made of host rocks of the different geological origin, according to the result of rare earth elements analysis.

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer (피부암치료를 위한 전자선 전신피부 치료방법과 선량분포 측정)

  • Chu, Sung-Sil;Loh, John-Jk;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Increasing frequency of skin cancer, mycosis fungoides, Kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a $0.5\;cm\times90\;cm{\times}180\;cm$ acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around the body. One treatment session delivered 400 cGy to the entire skin surface and patients were treated twice a week for eight consecutive weeks, which is equivalent to TDF value 57. instrumentation and techniques developed in determining the depth dose, dose distribution and bremsstrahlung dose are discussed.

  • PDF

A Monte Carlo Simulation for the Newly Developed Head-and-Neck IMRT Phantom: a Pilot Study (제작된 선량 검증용 IMRT 팬텀의 몬테칼로 시뮬레이션: 예비적 연구)

  • Kang, Sei-Kwon;Cheong, Kwang-Ho;Ju, Ra-Hyeong;Cho, Byung-Chul;Oh, Do-Hoon;Kim, Su-SSan;Kim, Kyoung-Ju;Bae, Hoon-Sik;Han, Young-Yih;Shin, Eun-Hyuk;Park, Sung-Ho;Lim, Chun-Il
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.126-133
    • /
    • 2007
  • A head-and-neck phantom was designed in order to evaluate remotely the quality of the delivery dose of intensity modulated radiation therapy (IMRT) in each institution. The phantom is homogeneous or inhomogeneous by interchanging the phantom material with the substructure like an air or bone plug. Monte Carlo simulations were executed for one beam and three beams to the phantom and compared with ion chamber and thermoluminescent dosimeter (TLD) measurements of which readings were from two independent institutions. For single beam, the ion chamber results and the MC simulations agreed to within about 2% TLDs agreed with the MC results to within 2% or 7% according to which institution read the TLDs. For three beams, the ion chamber results showed -5% maximum discrepancy and those of TLDs were $+2{\sim}+3%$. The accuracy of the TLD leadings should be increased for the remote dose monitoring. MC simulations are a valuable tool to acquire the reliability of the measurements in developing a new phantom.

  • PDF

Genetic Consideration of Sericite Deposits Derived from Granitic Rocks in the Taebaegsan Region (태백산지역에 분포하는 화강암체 기원 견운모광상의 성인적 고찰)

  • Yoo, Jang-Han;Chi, Sei-Jeong
    • Journal of the Mineralogical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.239-246
    • /
    • 2008
  • Yeongweol sericite deposit of Gangwon Province is regarded as one of the sericite deposits derived from granitic rocks due to post-magmatic alkali metasomatism, and the other sericite deposit of the same origin is the Daehyun mine of Gyungbug Province. Sericite ores were originated from leucocratic granitic stocks of Cambrian-Triassic age which intruded the pegmatitic migmatite of the unknown age and granite of the Pre-cambrian age, respectivcly. Jangsan quartzite of the lowermost formations of the Paleozoic era, which played as the capping rock protected from the leakage of the hydrothermal solution. It is well known that those sericite deposits arc formed during formation of the geosyncline, and they are also situated in the margins of the Hambaeg Syncline. Leucocratic granites commonly contain pegmatites with tourmaline crystals, and are rich in potassium feldspars, and sodium plagioclase as well. Sericitized ores are mainly found as we go up to the higher elevations or to the margins of the stocks. And some of the Highest grade sericite ores show the monominerallic character composed of nearly pure sericite probably doc to the ultra greisenization. Chemical analysis shows higher $Na_{2}O$ and $K_{2}O$ contents $(2.00\sim7.03wt%)$ as the sericitizations arc preceded and they represent obvious greisenization. But low CaO contents $(0.05\sim4.51wt%)$ indicate that albitizations are so weak. Pyrophyllite of the Youngweol area is often accompanied by the sericite, indicating rather stronger thermal effect than the Daehyun mine. It is known that there are several Sn deposits originated from greisenization in the Taebaegsan region. And greisens are inclined to contain W, Mo and several REE's such as Be, Nb and Li, and so Taebaegsan region interbedded with lots of carbonate formations are still worthwhile to survey for those metallic deposits.

Cloning, Sequencing and Expression of the Gene Encoding a Thermostable β-Xylosidase from Paenibacillus sp. DG-22 (Paenibacillus sp. DG-22로부터 열에 안정한 β-xylosidase를 암호화하는 유전자의 클로닝, 염기서열결정 및 발현)

  • Lee, Tae-Hyeong;Lee, Yong-Eok
    • Journal of Life Science
    • /
    • v.17 no.9 s.89
    • /
    • pp.1197-1203
    • /
    • 2007
  • A genomic DNA library of the bacterium Paenibacillus sp. DG-22 was constructed and the ${\beta}-xylosi-dase-positive$ clones were identified using the fluorogenic substrate $4-methylumbelliferyl-{\beta}-D-xylopyr-anoside$ $({\beta}MUX)$. A recombinant plasmid was isolated from the clone and 4.3-kb inserted DNA was sequenced. The ${\beta}-xylosidase$ gene (xylA) was comprised of a 2,106 bp open reading frame (ORF) en-coding 701 amino acids with a molecular weight of 78,710 dalton and a pI of 5.0. The deduced amino acid sequence of the xylA gene product had significant similarity with ${\beta}-xylosidases$ classified into family 52 of glycosyl hydrolases. The xylA gene was subcloned into the pQE60 expression vector to fuse with six histidine-tag. The recombinant ${\beta}-xylosidase$ $(XylA-H_6)$ was purified to homogeneity by heat-treatment and immobilized metal affinity chromatography. The pH and temperature optima of the $XylA-H_6$ enzyme were pH 5.5-6.0 and $60^{\circ}C$, respectively.

Dosimetry by Using EBT2 Film for Total Skin Electron Beam Therapy (TSET) (전신 피부 전자선 치료(TSET)에서 EBT2 필름을 사용한 선량측정)

  • Hwang, Ui-Jung;Rah, Jeong-Eun;Jeong, Ho-Jin;Ahn, Sung-Hwan;Kim, Dong-Wook;Lee, Sang-Yeob;Lim, Young-Gyung;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Park, Sung-Young;Pyo, Hong-Ryull;Chung, Weon-Kuu
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.60-69
    • /
    • 2010
  • For treatment of Total Skin Electron beam Therapy (TSET), measurement of dose at various conditions is need on the contrary to usual radiotherapy. When treating TSET with modified Stanford technique based on linear accelerator, the energy of treatment electron beam, the spatial dose distribution and the actual doses deposited on the surface of the patient were measured by using EBT2. The measured energy of the electron beam was agreed with the value that measured by ionization chamber, and the spatial dose distribution at the patient position and the doses at several point on the patient's skin could be easily measured by EBT2 film. The dose on the patient that was measured by EBT2 film showed good agreement with the data measured simultaneously by TLD. With the results of this study, it was proven that the EBT2 film can be one of the useful dosimeter for TSET.

A Case of Cat Scratch Disease Confirmed by Polymerase Chain Reaction for Bartonella henselae DNA (Bartonella henselae DNA에 대한 PCR 검사로 확진된 Cat Scratch Disease 1례)

  • Chung, Ju-Young;Koo, Ja Wook;Kim, Sang Woo;Yoo, Young Sam;Han, Tae Hee;Lim, Seong Jig
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.789-792
    • /
    • 2005
  • We report a case of cat scratch disease (CSD) caused by Bartonella henselae in a 14-year-old boy who developed lymphadenopathy in the right cervical area, after a raising canine pet for 10 months. The cervical lymphadenopathy persisted for 14 days. Immunofluorescent antibody testing for B. henselae with the patient's serum was 1:64 positive. Polymerase chain reaction (PCR) analysis using the patient's lymph node aspirates for B. henselae DNA was also positive. This is the first case of cat scratch disease confirmed by PCR for B. henselae DNA in children.