Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer
피부암치료를 위한 전자선 전신피부 치료방법과 선량분포 측정
- Chu, Sung-Sil (Department of Radiation Oncology, College of Medicine, Yonsei University) ;
- Loh, John-Jk (Department of Radiation Oncology, College of Medicine, Yonsei University) ;
- Kim, Gwi-Eon (Department of Radiation Oncology, College of Medicine, Yonsei University)
- Published : 1992.06.01
Abstract
Increasing frequency of skin cancer, mycosis fungoides, Kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a
4-5MeV의 전자선은 피부표면의 흡수선량을 증가시키고 표면하 10mm 내외에서 급속히 감소함으로 Mycosis fungoides, Kaposi's sarcoma등 전신피부암에 대한 가장적당한 치료방사선으로 알려져왔다. 그러나 평면이 아니고 굴곡이 심한 인체표면에 균일한 선량을 계획하기는 많은 어려움이 있었다. 연세암센터에서는 1980년부터 시행하여왔던 6MeV 전자선의 마름모형, 네방향 조사방법을 개량하고 많은 문헌을 참고하여 상하 양방향의 조사면과 환자위치를 각각 여섯가지 자세로 나누어 조사(Six-Dual-Field)하는 방법을 사용하였으며 이에따른 전신피부표면의 선량과 선량분포를 측정하였다. 선형가속기에서 발생되는 6MeV 전자선을 0.5 cm 두께의 아크릴판으로 감약시키고 콜리메터가 완전히 열린 조사면을 상하