• Title/Summary/Keyword: 열판

Search Result 45, Processing Time 0.032 seconds

A Comparative Study on the Mechanical Properties of Plywood treated with Several Fire-Retardant Chemicals(II) - Effect of Platen Temperature in Press Drying on the Static Bending Strength of Treated Plywood - (수종(樹種) 내화약제(耐火藥劑)로 처리(處理)된 합판(處理)의 기술적(技術的) 성질(性質)에 관(關)한 비교연구(比較硏究)(II) - 열판건조시(熱板乾燥時) 열판온도(熱板溫度)가 처리합판(處理合板)의 휨강도(强度)에 미치는 영향(影響) -)

  • Chung, Woo-Yang;Kim, Jong-Man;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.12-18
    • /
    • 1984
  • Soaking treated in 20% aqueous solutions of $(NH_4)_2SO_4$, $NH_4H_2PO_4$, $(NH_4)_2HPO_4$, $Na_2B_4O_7-H_3BO_3$(60:40) and Minalith, the mixed salts for 9 hrs. the wet 3.5mm meranti (Parashorea spp.) plywoods were press-dried at 90, 120 and $150^{\circ}C$ and put to static bending test to examine the influence of redrying temperature on the strength of fire-retardant treated plywoods ill flexure. While water-soaking treatment (control) showed serious reduction in Stress at proportional limit, MOE, MOR, Work per unit volume at $150^{\circ}C$, all the fire-retardant treatments maintained bending strength even at $150^{\circ}C$ and showed rather increased values in case of some chemicals. In view of drying rate and maintenance of strength, the most pertinent platen temperature was $150^{\circ}C$ and Borax-Boric acid was the predominant fire-retardant in this study.

  • PDF

Study on Press-drying of Italian Poplar Board and its Effect on Improvement of Wood Property (이태리포푸라재(材)의 건조성(乾燥性) 및 성질개선(性質改善)에 관(關)한 연구(硏究))

  • Jung, Hee Suk
    • Journal of Korean Society of Forest Science
    • /
    • v.37 no.1
    • /
    • pp.17-30
    • /
    • 1978
  • Press drying was used on italian poplar (Populus euamericana) to find the profitable means of drying. This study was designed to investigate the process of platen drying considering core temperature, drying time, current moisture content, drying rate, shrinkage and recovery, and green volume specific gravity, equilibrium moisture content and dimensional stability of press dried material and air dried material, The drying tests were conducted using 1.5 centimeter thick material at platen temperature of $175^{\circ}C$. The results were summarized as follows. 1. Core temperature was divided into three stages of drying characterized by period initial heating, plateau temperature and rising core temperature. Plateau temperature was 114 to $119^{\circ}C$. 2. The following predicting equations of drying time(y) in different core temperatures were developed for initial thickness($x_1$), initial moisture content ($x_2$) and final moisture content ($x_3$) 3. The predicting equaltion of current moisture content(u) was log u=4.658-0.060t as funtion of drying time(t) and that of drying rate(r) was log r=-2.797-0.049t. Current moisture content and drying rate of air drying were shown in figure 2. 4. The predicting equation of shrinkage in thickness direction(y) was log y=1.933+0.038t as function of drying time(t), and that of expansion in width direction was $y=-0.692+0.043t-0.001t^2$. 5. Thickness shrinkage was increased more than proportional at to pressure increase. Width shrinkage and thickness recovery was greatest at 35psi. 6. Green volume specific gravity of press dried material was 25% greater than that of air dried material. But equilibrium moisture content of press dried material was less 24% than that of air dried material. Antishrinkage efficiency of press dried material were obtained 27.7%.

  • PDF

Redrying Fire - Retardant - Treated Structural Plywood (구조용(構造用) 내화처리(耐火處理) 합판(合板)의 재건조(再乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Schaffer, E.L.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.1-21
    • /
    • 1981
  • Exterior grades of Douglas-fir and aspen plywood were impregnated with interior fire-retardant chemicals and redried under low-, intermediate-, and high-temperature drying conditions. Fire-retardant treatments included borax-boric acid, chromated zinc chloride, minalith, pyresote, and a commercial formulation. Drying processes included kiln and press-drying. Evaluated were drying rates and defects generated. The borax-boric acid and the commercial treatments redried at rates similar to water-treated controls. Other salt treatments were significantly slower drying and more defect prone. Chromated zinc chloride treatment was consistently the slowest drying and most defect prone. Press drying was three times faster at an equivalent temperature level. However, thickness shrinkage doubled because of 50 1b/in. platen pressure.

  • PDF

Properties of the carbon electrode perovskite solar cells with various annealing processes (열처리 방법에 따른 카본전극 페로브스카이트 태양전지의 특성 변화)

  • Song, Ohsung;Kim, Kwangbea
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.26-32
    • /
    • 2021
  • The photovoltaic properties and microstructure changes were observed while perovskite solar cells (PSCs) with a fabricated carbon electrode were formed using the following annealing processes: hot-plate, oven, and rapid thermal annealing (RTA). Perovskite solar cells with a glass/FTO/compact TiO2/meso TiO2/meso ZrO2/carbon structure were prepared. The photovoltaic properties and microstructure changes in the PSCs were analyzed using a solar simulator, optical microscopy, and field emission scanning electron microscopy. An analysis of the photovoltaic properties revealed outstanding properties when RTA was applied to the cells. Microstructure analysis showed that perovskite was formed locally on the carbon electrode surface when hot-plate and oven annealing were applied. On the other hand, PSC with RTA showed a flat surface without extra perovskite agglomeration. Denser perovskite formed on the porous carbon electrode layer with RTA showed superior photovoltaic properties. These results suggest that the RTA process might be appropriate for the massive production of carbon electrode PSCs considering the processing time.

Drag Reduction in Turbulent Channel flow with Periodically Arrayed Heating and Cooling Strips (난류 채널 내 냉·열판 부착에 의한 마찰저항 감소)

  • Yoon, Hyun-Sik;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.608-618
    • /
    • 2005
  • A new technique giving significant drag reduction in turbulent shear flows has been proposed by using the buoyancy effect to generate periodic spanwise motion. Such spanwise motion can be obtained by arranging heating and cooling strips periodically aligned in the spanwise direction of a vertical channel, where the streamwise mean flow is perpendicular to the gravity vector The strip size has been changed in order to obtain the optimum size corresponding to the maximum drag reduction. The bulk Reynolds number, $ Re_{m} = U_{m} \delta / \nu \$ is fixed at 2270 while Grashof numbers is changed between $10^{6}$ to $10^{7}$. As Grashof number increases, considerable drag reduction can be obtained, At the highest Grashof number, an optimum strip size of about 250 wail units gives drag reduction of about 35$\%$. The greater the Grashof number, the smaller the strip size attains the maximum drag reduction.

Anti-nociceptive Effect of Bee Venom on Capsaicin or Bradykinin-induced Pain (Capsaicin이나 Bradykinin으로 유발된 통증에 대한 봉독의 억제 효과)

  • Yang, Chang-Yeol;Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.24 no.2
    • /
    • pp.39-49
    • /
    • 2007
  • 목적 : 봉독으로 유발된 통각수용의 강도와 봉독으로 나타나는 항통각수용(통각억제성)의 강도를 쥐의 포르말린 테스트를 통해 상호관련됨을 확인하고 capsaicin과 bradykinin으로 통증 유발된 쥐의 자발적인 통증행동(핥기횟수측정; LN), 꼬리경타시험(TFL)과 열판시험(HPL)을 통해 봉독의 항통각수용(통각억제)작용을 재확인 하고자 하였다. 방법 : 쥐의 뒷다리에 통증유도 물질인 Capsaicin 또는 Bradykinin을 20${\mu}l$를 주사하여 동통을 유발하고 자발적 통증행동인 핥기횟수측정(LN), 꼬리경타기간(TFL)과 열판 위에서의 온도자극에 쥐가 반응하는 시간을 측정(HPL)하는 실험을 봉독을 주입하거나, 몰핀을 주입하거나, 아무것도 주입하지 않고 통증유발만 시킨 이후에 각각 시행하였다. 결과: 1. Capsaicin 또는 Bradykinin으로 동통유발 후 LN은 두드러증가를 보임, HPL은 감소를 TFL은 두드러진 감소를 나타내었다. 2. 봉독이나 몰핀 주입 30분 후에 Capsaicin으로 동통유발 이후 LN은 봉독과 몰핀에서 모두 현격한 감소를, HPL은 봉침은 현격한 증가를, 몰핀에서는 감소를, TFL은 봉침과 몰핀에서 모두 현격한 증가를 나타내었다. 3 봉독과 몰핀주입 30분후에 Bradykinin으로 동통유발 이후 LN은 봉독은 증가 몰핀은 현격한 감소를, HPL은 봉침은 증가 몰핀에서는 현격한 증가를, TFL은 봉침과 볼핀에서 모두 증가를 나타내었다. 결론 : 봉독은 Capsaicin 또는 Bradykinin으로 동통유발된 통각수용행동을 감소시키는 결과를 나타내었는데 이것은 기존의 연구결과들에서의 봉독의 항통각수용(통각억제성)의 효과를 입증하였고 봉약침은 염증의 개선이나 암과 관련된 동통에 유효한 방법임을 시사하는 것이다.

  • PDF

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

Application of Microwave Digestion Pretreatment Techniques for ICP-AES Analysis of Used Monolithic Automobile Catalysts Having Platinum Group-Metals and Silicates (백금족 금속과 규산염을 포함하는 모노리스형 자동차 폐촉매의 ICP-AES 분석을 위한 극초단파 분해 전처리 기법의 응용)

  • Kim, Choong-Hyon;Woo, Seong Ihl;Jeon, Sung Hwan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.568-575
    • /
    • 1999
  • Two different digestion procedures for the simultaneous determination of major and platinum-group element(PGE) in spent automobile catalysts containing PGE and silicates by inductively coupled plasma atomic emission spectrometry(ICP-AES) are compared. Combinations of mixed aids using HF, $HNO_3$, HCl, $HClO_4$, $H_2O_2$, and $H_3BO_3$ are utilized for the hot plate dissolution method and the closed-vessel microwave digestion method, The latter method has been shown to be relatively superior in terms of recovery, analysis time, and amount of aqua regia (3 parts HCl + part $HNO_3$ required to dissolve PGE in comparison with conventional open vessel hot-plate dissolution. The best results were drawn from the following conditions: In closed Teflon PFA vessels under microwave heating with temperature/pressure regulation, a 0.25 g portion of sample was digested in 2 mL of HF, 2 mL of $HNO_3$ and 6mL of HCl under the pressure of 200 psi(13.79 bar) at $180^{\circ}C$ for 1hr, followed by a second digestion stage with 16 mL of 5%(w/v) boric acid under the pressure of 20 psi(1.38 bar) at $100^{\circ}C$ for 10 min. After the microwave heating, the sample was post-treated with 10 mL of aqua regia twice by hot-plate heating. This condition gives the PGE recovery within 85~110% and the relative standard deviations within 2%. The method developed can therefore be regarded as an alternative method for routine analysis of spent automobile catalysts.

  • PDF

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF