A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger- (원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 -)

  • 이찬규;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.251-258
    • /
    • 1990
  • Optimal design of heat exchanger for closed CO$_{2}$ gas turbine plant of three processes selected from the result of cycle analysis have been discussed previously paper(I) has been carried out under specified inlet and outlet conditions. Independent variables such as number of parallel connection, tube diameter, shell side and tube side pressure loss as well as dependent variables such as shell diameter, number of tubes, number of serial connections were all characterized according to the standardization or so. Search method was used to construct a computer simulation together with the calculation of heat transfer rate by logarithmic mean temperature difference method. Strength analysis of major parts was carried to examine their dimensions satisfying heat transfer and pressure loss requirements.

Investigation of Turbulent Flow Effect in Segmented Arc Heater (아크히터 내부의 난류 효과에 대한 고찰)

  • Lee, Jeong-Il;Kim, Kyu-Hong;Kim, Chong-Am
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.5
    • /
    • pp.1-8
    • /
    • 2005
  • Flows in segmented arc-heaters have been calculated for prediction of experimental operating condition or for analysis and design of arc-heater itself. Some researchers succeeded in calculating accurately inner flows of a arc-heater, but could not made mathematical models which satisfy various operating conditions for many arc-heaters. this study is forced on turbulence for the generality of mathematical model. Instead of algebraic turbulence models which are frequently used for calculating inner flow of arc-heater, two equation turbulent models are used. Prediction results agree well with experiment data and it was confirmed that $k-\varepsilon$ two equation turbulence model is appropriate for a flow in an arc heater throughout extensive numerical testing.

LES for Turbulent Channel Flow with Blowing Velocity (분류유동이 있는 채널 난류유동의 LES 해석)

  • Na, Yang;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.8
    • /
    • pp.699-705
    • /
    • 2007
  • Recent experimental data shows that the noticeable feature of irregular roughened spots on the fuel surface occurs during the combustion test with PMMA/GOX in the hybrid rocket motor. The generation of these unexpected patterns is likely to be resulted from the disturbed boundary layer due caused by wall blowing which is intented to simulate the process of fuel vaporization. LES technique was implemented to investigate both the flow characteristics near fuel surface and the subsequent evolution of turbulence modified by the wall blowing. Simple channel geometry instead of circular grain configuration was used for the investigation without chemical reactions in order to allow for a focused examination on the near-wall behavior at the Reynolds number of 22,500. It was shown that the wall blowing pushed turbulent structures upwards making them tilted and this skewed displacement, in effect, left the foot prints of the structures on the surface. This change of kinematics may explain the formation of irregular isolated spots on the fuel surface observed in the experiment.

Investigating the scaling effect of the nonlinear response to precipitation forcing in a physically based hydrologic model (강우자료의 스케일 효과가 비선형수문반응에 미치는 영향)

  • Oh, Nam-Sun;Lee, K.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.149-153
    • /
    • 2006
  • Precipitation is the most important component and critical to the study of water and energy cycle. This study investigates the propagation of precipitation retrieval uncertainty in the simulation of hydrologic variables for varying spatial resolution on two different vegetation cover. We explore two remotely sensed rain retrievals (space-borne IR-only and radar rainfall) and three spatial grid resolutions. An offline Community Land Model (CLM) was forced with in situ meteorological data In turn, radar rainfall is replaced by the satellite rain estimates at coarser resolution $(0.25^{\circ},\;0.5^{\circ}\;and\;1^{\circ})$ to determine their probable impact on model predictions. Results show how uncertainty of precipitation measurement affects the spatial variability of model output in various modelling scales. The study provides some intuition on the uncertainty of hydrologic prediction via interaction between the land surface and near atmosphere fluxes in the modelling approach.

  • PDF

An Experimental Study on the Effect of Longitudinal Ventilation on the Variation of Burning Rate in Tunnel Fires (터널 화재시 종류식 환기가 연소율 변화에 미치는 영향에 관한 실험적 연구)

  • Yang Seung Shin;Kim Sung Chan;Ryou Hong Sun
    • Tunnel and Underground Space
    • /
    • v.15 no.1 s.54
    • /
    • pp.55-60
    • /
    • 2005
  • In this study, the 1/20 reduced-scale experiments using Froude scaling were conducted to investigate the effect of longitudinal ventilation on the variation of burning rate in tunnel fires. The methanol square pool fires with heat release rate ranging from 3.57 kW to 10.95 kW were used. The burning rate of fuel was obtained by measured mass using load cell and temperature distribution were measured by K-type theomocouples in order to investigate smoke movement. The wind tunnel was connected with one side of the tested tunnel, and logitudinal ventilation velocity in the tested tunnel was controlled by power of the wind tunnel. In methanol fire case, the increase in ventilation velocity decreased the turning rate due to the direct cooling of fire plume. For the same dimensionless velocity(V), homing rate decreased as the size of pool fire increased.

Open-Cell Rigid Polyurethane Foam Using Reactive Cell Opening Agents (반응성 기포개방제를 이용한 개방기포형 경질우레탄폼)

  • Ahn, WonSool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2524-2528
    • /
    • 2013
  • Cell opening characteristics dependent on the cell openers for the conventional formulation of a closed-cell polyurethane foam (PUF) was studied using 1-butanol and lithium salt of 12-hydroxystearic acid (Li-12HSA) as the reactive cell opening agents. While cell openining content of only 10.5 % was obtained for the sample with 4 phr of 1-butanol as the single reactive cell opener, that of 98.0% could be obtained for the sample with 2 phr of Li-12HSA as the reactive co-cell opener. As the results, it showed that a fully open-cell rigid PUF could be obtained by introducing a novel reactive cell opener, having a functional group able to form a bulky side-chain on the urethane networks, without severe loss of mechanical properties of the closed-cell PUF like cell size, bulk density, and thermal conductivity.

Drying Characteristics of a Radiative Industrial Dryer Adopting a Mat-Type Premixed Catalytic Burner (매트 형태의 예혼합 촉매 버너에 의한 복사 건조 특성)

  • Kim, Hyouck-Ju;Ahn, Joon;Song, Kwang-Sup
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.735-742
    • /
    • 2011
  • A catalytic burner that utilizes the thermal energy from fossil fuels without the emission of nitrogen oxides ($NO_x$) has been developed. For this purpose, the newly developed burner has two features: firstly, it is in the shape of a flat mat so as to maximize its heating surface, and secondly, it adopts premixed combustion so that it can be used in a closed space. In the present study, the burner was used in a radiation-type industrial dryer. This dryer yields thermal energy in the form of thermal radiation in the infrared regime, which has been proved to be effective for drying organic substances under low-moisture conditions. Analysis of the experimental data has proved that the thermal efficiency of the dryer is better correlated to the moisture than to the dry rate

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

A Study on the Fire Resistance of yLRC Composite Columns with Steel Sheet Forms and Angles (강재 영구거푸집을 사용한 yLRC 합성기둥의 내화성능 연구)

  • Kim, Bo Ram;Kang, Seong Deok;Kim, Hyung Geun;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.3
    • /
    • pp.365-375
    • /
    • 2008
  • The main objective of this paper is to study the behaviour of yLRC composite columns at elevated temperatures by experimental test. The effects of load ratios, cross-section size and fire protection for the yLRC columns were investigate d by the test and compared using the heat transfer analysis perfo rmed based on the finite element program ANSYS 10.0 using the ISO834 standard fire curve, following the main guidelines proposed by the EC4 Part 1.2. As heat transfer is the movement of heat by conduction, convection, and radiation, and as temperature inside an object varies by position and time, time. As the steel's thermal conductivity is higher than that of concrete, steel loses its strength rapidly in a high-temperature situation such as a fire. Fire resistance performance of the yLRC composite column under fire conditions was evaluated througheat transfer analysis for parametric study.

A Study on Radiation Shielding for Grid-stiffened Multi-Functional Composite Structures (격자-강화된 다기능 복합재 구조체의 방사차폐에 관한 연구)

  • Jang, Tae Seong;Rhee, Juhun;Seo, Hyun-Suk;Hyun, Bum-Seok;Kim, Taig Young;Seo, Jung Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.629-639
    • /
    • 2014
  • This paper deals with an alternative multi-functional structures by using grid-stiffened composite structure with excellent bending stiffness and lightweight characteristics which is capable of easy embedding of electrical/electronic circuitry into structure. The enhancement of thermal conduction capability is made by the application of pitch-based carbon fiber. The lightweight radiation spot shielding technique is also proposed for multi-functional structures without conventional housing and the effectiveness of selective radiation shielding is validated through the proton irradiation test.