A Study of th Optimum of closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(II) - For Optimal Design of Heat Exchanger-

원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 (II) -열교환기의 설계에 관하여 -

  • 이찬규 (경희대학교 대학원) ;
  • 이종원 (경희대학교 공대 기계공학과)
  • Published : 1990.04.01

Abstract

Optimal design of heat exchanger for closed CO$_{2}$ gas turbine plant of three processes selected from the result of cycle analysis have been discussed previously paper(I) has been carried out under specified inlet and outlet conditions. Independent variables such as number of parallel connection, tube diameter, shell side and tube side pressure loss as well as dependent variables such as shell diameter, number of tubes, number of serial connections were all characterized according to the standardization or so. Search method was used to construct a computer simulation together with the calculation of heat transfer rate by logarithmic mean temperature difference method. Strength analysis of major parts was carried to examine their dimensions satisfying heat transfer and pressure loss requirements.

본 연구에서는 제 1보에서 다루었던 프로세스 해석의 결과들을 토대로 하여 열교환기의 최적 설계를 행하는데 주력하였다. 먼저, 열교환기의 최적 설계를 행하 는데 주력하였다. 먼저, 열교환기의 열설계에 필요한 CO$_{2}$와 Natrium의 물성치 및 열전달에 관한 기존의 실험식들을 여러문헌으로부터 연구 검토한 후 프로그램에 편 리하게 이용할 수 있도록 전산화 하였으며, 열교환기의 설계시 필요한 전체 경비의 최 소화를 기하는 방향으로 최적화된 설계인자들을 결정하도록 시도하였고 또한 최적화된 프로그램을 개발함으로써 인력, 외화 및 에너지 절감의 효과를 얻고자 하였다.

Keywords