• Title/Summary/Keyword: 열전도 모델

Search Result 627, Processing Time 0.028 seconds

Design Optimization of Bracket for Wear Sensor of Automobile Brake Pads Based on Dynamic Kriging Surrogate Model (자동차 브레이크 패드 마모량 측정센서 브라켓의 다이나믹크리깅 대리모델 기반 설계최적화)

  • Jun-Yeong Jeong;Jung Joo Yoo;Kyung Seok Byun;Hyunkyoo Cho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.2
    • /
    • pp.95-101
    • /
    • 2024
  • This paper introduces an optimized design for a sensor bracket used to measure the wear amount of an automobile brake pad, based on a dynamic kriging surrogate model. During testing, the temperature of the brake pad can increase beyond 600℃, which often causes sensor malfunction. Therefore, it is essential to optimize the shape of the sensor bracket to minimize heat transfer. To reduce the computational cost of the optimization, the heat-transfer simulation is replaced by a dynamic kriging surrogate model. Dynamic kriging utilizes the best combination of correlation and basis functions and constructs an accurate surrogate model. Following optimization, the temperature of the sensor position decreases by 7.57%. The results from the surrogate model under optimum conditions are verified by a heat-transfer simulation, and the design optimization using a surrogate model is found to be effective.

Thermal Analysis of Electronic Devices in an Onboard Unit Considering Thermal Conduction Environment (열전도 환경을 고려한 전장탑재물의 소자 열 해석)

  • Kim Joon-Yun;Kim Bo-Gwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.5 s.311
    • /
    • pp.60-67
    • /
    • 2006
  • Thermal analysis and prediction of electronic components is required to predict and optimize the reliability of onboard electronic unit employed in space vehicles. This paper introduces a methodology on thermal prediction that uses isothermal PCB model, thermal force model, thermal resistance matrix and superposition principle to calculate electronic devices temperatures undergoing thermal conduction environment. An example is Presented including a prediction result by this method and simulation results performed by commercial program.

Pressure Drop Reduction and Heat Transfer Increase with Rheological Fluid Flows in a Circular Conduit (원형 도관 내에서의 유변 유체에 대한 압력손실 감소 및 열전달 증가)

  • Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2012
  • 본 연구는 컴팩트한 열교환기의 설계를 위하여 열교환기 내의 원형 단면 도관의 유변 유체의 압력 강하 및 대류 열전달률을 수치해석적으로 수행하였다. 유변 유체의 구성방정식은 기존의 비뉴톤 유체 멱법칙을 보완한 수정 멱법칙 모델을 채택하였다. 도관 내의 압력강하를 의미하는 마찰계수와 수정 레이놀즈 수의 곱은 기존 문헌치와 비교할 때 뉴톤 유체 영역과 유변 멱법칙 영역에서 각각 0.01% 및 0.004% 내에서 일치함을 보였고 유변 수정멱법칙 유체 모델의 형태를 띠는 유변 유체를 열교환기 내의 원형 단면 도관 내에서 사용하면 뉴톤 유체보다 최대 58%의 압력강하를 감소시켰고 최대 9%의 대류 열전달 증가을 발생시킬 수 있었다.

Analysis of Space Charge Propagation in a Dielectric Liquid Employing Field-Thermal Electron Emission Model and Finite Element Method (유한요소법과 전계-열전자 방출 모델에 의한 절연유체 내 공간전하 전파해석)

  • Lee, Ho-Young;Lee, Se-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1406_1407
    • /
    • 2009
  • Fowler-Nordheim의 전자 방출과 열전자 방출 메카니즘을 이용하여 절연유체 내 전계에 의한 도체의 음극에서 전자 방출현상과 열에 의한 열전자 방출현상을 고려하고 유한요소법(Finite Element Method)을 이용하여 해석하였다. 절연유체 내 공간전하에 대한 해석기법으로 푸아송 방정식, 양이온, 음이온, 전자에 대한 전하연속 방정식, 온도에 대한 열 확산 방정식으로 이루어진 5개의 지배방정식에 Fowler-Nordheim의 전계 방출과 Richardson-Dushman의 열전자 방출을 경계조건으로 부여하였다. 단자 전류는 유한요소법과 잘 부합하는 에너지법으로 계산되었다. 쌍 곡선형 PDE의 공간전하 전파에 대한 지배 방정식은 일반적으로 수치적인 불안정성을 가지므로 인공 확산 항을 고려하여 이를 해결하였다. 제안된 해석법은 세 개의 캐리어를 가진 x-y 좌표축의 2차원 평판 모델에 적용하여 그 유효성을 확인하였다.

  • PDF

액막의 유동 및 온도계산 모델에 의한 PCCS 열전달 현상 해석

  • 김성오;황영동;김영인;배윤영;장문희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.584-589
    • /
    • 1998
  • 범용 전산유체 해석코드인 CFX 4.1을 사용하여 철재격납용기 표면을 전열면으로 이용하는 피동격납용기냉각계통에 대한 열전달 현상해석을 수행하였다. 철재격납용기 내부와 외부 채널에서 발생하는 열전달 현상을 모사하기 위하여 액막의 유동 및 온도계산 모델을 범용 전산유체해석코드인 CFX4.1에 적용하여 철재격납용기 내.외부의 표면을 흐르는 액막의 높이, 액막내 온도분포, 철재격납용기 내.외부의 온도, 유속 및 부피분율 등을 계산하는 복합 열전달 해석 방법론을 개발하였다. 해석결과는 향후 실험 둥을 통한 검증이 필요하나 피동형 격납용기템각계통에서 발생하는 물리적 현상들의 복합적인 거동 분석에 사용될 수 있는 것으로 평가되었다.

  • PDF

Asymptotic Approach to Pressure Drop and Heat Transfer in a Rectangular Pipe with Shear-thickening Fluids (사각형 단면 파이프 내에서의 Shear-thickening 유체를 이용한 압력강하 및 열전달 예측에 대한 점근적 해석)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.23-30
    • /
    • 2011
  • 본 연구는 산업용 열교환기 및 상용 파이프의 최적 설계를 위하여 열교환기 내의 사각형 단면 파이프의 shear-thickening 비뉴톤 유체의 압력강하 및 대류 열전달률을 수치해석적으로 수행하였다. shear-thickening 유체의 구성 방정식은 기존의 비뉴톤 유체 멱법칙을 보완한 확장 멱법칙 모델을 채택하였다. 파이프 내의 압력강하를 의미하는 마찰계수와 확장 레이놀즈 수의 곱은 기존 연구의 비교자료와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.018% 및 0.06% 내에서 일치함을 보였고, 대류 열전달률을 의미하는 뉴셀트 수는 문헌치와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.025% 및 0.14% 내에서 일치함을 보였다. 비뉴톤 확장 멱법칙 유체 모델의 형태를 띠는 shear-thickening 유체를 열교환기 또는 상용파이프 내의 사각형 단면 파이프 내에서 사용하면 유동지수(n)에 따라서 뉴톤 유체보다 최대 160%의 압력강하를 증가시켰고 최대 14%의 대류 열전달 감소를 발생시킬 수 있었다.

Estimation of Overall Heat Transfer Coefficient for Single Layer Covering in Greenhouse (일중 피복온실의 관류열전달계수 산정)

  • Hwang, Young-Yun;Lee, Jong-Won;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.108-115
    • /
    • 2013
  • This study was conducted to suggest a model to calculate the overall heat transfer coefficient of single layer covering for various greenhouse conditions. There was a strong correlation between cover surface temperature and inside air temperature of greenhouse. The equations to calculate the convective and radiative heat transfer coefficients proposed by Kittas were best fitted for calculation of the overall heat transfer coefficient. Because the coefficient of linear regression between the calculated and measured cover surface temperature was founded to 0.98, the slope of the straight line is 1.009 and the intercept is 0.001, the calculation model of overall heat transfer coefficient proposed by this study is acceptable. The convective heat transfer between the inner cover surface and the inside air was greater than the radiative heat transfer, and the difference increased as the wind speed rose. The convective heat transfer between the outer cover surface and the outside air was less than the radiative heat transfer for the low wind speed, but greater than for the high wind speed. The outer cover convective heat flux increased proportion to the inner cover convective heat flux linearly. The overall heat transfer coefficient increased but the cover surface temperature decreased as the wind speed increased, and the regression function was founded to be logarithmic and power function, respectively.

Empirical model to estimate the thermal conductivity of granite with various water contents (다양한 함수비를 가진 화강암의 열전도도 추정을 위한 실험적 모델)

  • Cho, Won-Jin;Kwon, Sang-Ki;Lee, Jae-Owan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.2
    • /
    • pp.135-142
    • /
    • 2010
  • To obtain the input data for the design and long-term performance assessment of a high-level waste repository, the thermal conductivities of several granite rocks which were taken from the rock cores from the declined borehole were measured. The thermal conductivities of granite were measured under the different conditions of water content to investigate the effects of the water content on the thermal conductivity. A simple empirical correlation was proposed to predict the thermal conductivity of granite as a function of effective porosity and water content which can be measured with relative ease while neglecting the possible effects of mineralogy, structure and anisotropy. The correlation could predict the thermal conductivity of granite with the effective porosity below 2.7% from the KURT site with an estimated error below 10%.

Variation of time-dependent convection beat transfer coefficients in beat transfer analysis at various initial beating rates of tunnel fire scenarios (요소제거모델을 활용한 열전달해석에서 터널 화재이력곡선의 초기가열구배에 따른 대류열전달계수의 변화)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Jun-Hwan;Ahn, Sung-Yol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.223-237
    • /
    • 2010
  • The initial heating rate is well known as one of the most influencing factors on the occurrence of spalling and the loss of strength in concrete after fire initiation. In this study, a series of fire tests were carried out at different initial heating rates to find out its effects on the deterioration of tunnel structural members. Heat transfer analyses combined with an element elimination model were also carried out to verify its applicability in the same conditions as the fire tests. Moreover, the convection heat transfer coefficients compatible with fire test results were derived from parametric studies. In this course, their time-dependent variations were also analyzed at different initial heating rates. Finally, a numerical formula to estimate the heat transfer coefficients at the various initial heating rates was proposed by the interpolation of the results of numerical analyses.

대형용기의 열저항에 의한 열특성시험

  • 방경식;이주찬;서기석;도재범;민덕기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.350-355
    • /
    • 1997
  • PWR 사용후핵연료 집합체를 운반하기 위한 대형용기는 다층구조로 구성되며, 충과 층사이의 접합부에서의 열전달이 발생한다. 이러한 열전달은 고체간의 열전달과 접합부에서의 공극안 기체를 통한 열전달로 구분되며, 후자에 의한 영향을 크게 받는다. 따라서, 2개의 chamber로 구성된 고온열시험장치에 대형용기의 section모델을 넣고 각각의 chamber에 다른 열용량을 유입한 시험을 수행하고 동일조건하의 열해석을 수행하여 열저항계수를 산출하였다.

  • PDF