Loading [MathJax]/jax/output/CommonHTML/jax.js
  • Title/Summary/Keyword: 열전도도 측정

Search Result 273, Processing Time 0.024 seconds

Effect of pore-water salinity on freezing rate in application of rapid artificial ground freezing to deep subsea tunnel: concentration of laboratory freezing chamber test (고수압 해저터널에 급속 인공동결공법 적용시 간극수의 염분 농도가 동결속도에 미치는 영향 평가: 실내 동결챔버시험 위주로)

  • Oh, Mintaek;Lee, Dongseop;Son, Young-Jin;Lee, In-Mo;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.401-412
    • /
    • 2016
  • It is extremely difficult to apply conventional grouting methods to subsea tunnelling construction in the high water pressure condition. In such a condition, the rapid artificial freezing method can be an alternative to grouting to form a watertight zone around freezing pipes. For a proper design of the artificial freezing method, the influence of salinity on the freezing process has to be considered. However, there are few domestic tunnel construction that adopted the artificial freezing method, and influential factors on the freezing of the soil are not clearly identified. In this paper, a series of laboratory experiments were performed to identify the physical characteristics of frozen soil. Thermal conductivity of the frozen and unfrozen soil samples was measured through the thermal sensor adopting transient hot-wire method. Moreover, a lab-scale freezing chamber was devised to simulate freezing process of silica sand with consideration of the salinity of pore-water. The temperature in the silica sand sample was measured during the freezing process to evaluate the effect of pore-water salinity on the frozen rate that is one of the key parameters in designing the artificial freezing method in subsea tunnelling. In case of unfrozen soil, the soil samples saturated with fresh water (salinity of 0%) and brine water (salinity of 3.5%) showed a similar value of thermal conductivity. However, the frozen soil sample saturated with brine water led to the thermal conductivity notably higher than that of fresh water, which corresponds to the fact that the freezing rate of brine water was greater than that of fresh water in the freezing chamber test.

An Experimental Study on the Waste Polyethylene Aggregate for Construction Materials (폐비닐 골재의 기본특성에 관한 연구)

  • Kim, Young-Chin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.4
    • /
    • pp.5-16
    • /
    • 2003
  • The aggregate out of waste polyethylene was made in order to recycle waste polyethylene wasted in the country side. Many physical and mechanical experiments which include leaching test, specific gravity test, compaction test, LA abrasion test, large-scaled shear test, and permeability test were performed for the waste polyethylene aggregate. The thermal conductivity test, unfrozen water content test and frost heave test were also performed. The temperature distribution for both gravels and waste polyethylene aggregate, which were constructed in the frost heave layer in the field, was measured in winter season of continuous 2 years and compared.

  • PDF

Effect of initial ground temperature measurement on the design of borehole heat exchanger (초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향)

  • Song, Yoon-ho;Kim, Seong-Kyun;Lee, Kang-Kun;Lee, Tae-Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

An Experimental Study on the Thermal Performance Measurement of Vertical Borehole Heat Exchanger(BHE) (수직형 지열 열교환기(BHE)의 열성능 측정에 관한 실험적 연구)

  • Lim Kyoung-Bin;Lee Sang-Hoon;Soung Nak-Won;Lee Chang-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.764-771
    • /
    • 2006
  • Knowledge of ground thermal properties is most important for the proper design of large BHE(borehole heat exchanger) systems. Thermal response tests with mobile measurement devices were first introduced in Sweden and USA in 1995. Thermal response tests have so far been used primarily for in insitu determination of design data for BHE systems, but also for evaluation of grout material, heat exchanger types and ground water effects. The main purpose has been to determine insitu values of effective ground thermal conductivity, including the effect of ground-water flow and natural convection in the boreholes. Test rig is set up on a small trailer, and contains a circulation pump, a heater, temperature sensors and a data logger for recording the temperature data. A constant heat power is injected into the borehole through the pipe system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance.

Measurement and Verification of Thermal Conductivity of Multilayer Thin Dielectric Film via Differential 3ω Method (차등 3ω 기법을 이용한 다층 유전체 박막의 열전도도 측정 및 검증)

  • Shin Sang-Woo;Cho Han-Na;Cho Hyung-Hee
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.254-259
    • /
    • 2005
  • In this study, measurement of thermal conductivity of multilayer thin dielectric film has been conducted via differential 3ω method. Also, verification of differential 3ω method has been accomplished with various proposed criteria. The target film for measurement is 300 nm silicon dioxide and this thin film is covered with various thicknesses of upper protective layer. The upper protective layer is inserted between the target film and the heater line for purpose of electrical insulator or anti-oxidation barrier since the target film may be a good electrical conductor or a well-oxidizing material. However, the verification of differential 3ω method has not been conducted. Thus we have shown that the measurement of thermal conductivity of thin films with upper protective layer via differential 3ω method is verified to be reliable as long as the proposed preconditions are satisfied. Experimental results show that the experimental errors tend to increase with aspect ratio between upper protective layer thickness and width of the heater line due to heat spreading effect.

  • PDF

Thermal conductivity and properties of sheath alloy for High-Tc superconductor tape (고온초전도 선재용 피복합금의 열전도도 측정 및 특성평가)

  • 박형상;지봉기;김중석;임준형;오승진;오승진;주진호;나완수;유재무
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.8
    • /
    • pp.711-717
    • /
    • 2000
  • Effect of alloying element additions to Ag on thermal conductivity electrical conductivity and mechanical properties of sheath materials for BSCCO tapes has been characterized. The thermal conductivity at low temperature range(10~300K) of Ag alloys were evaluated by both direct and indirect measurement techniques and compared with each other. It was observed that thermal conductivity decreased with increasing the content of alloying elements such as Au, Pd and Mg. Thermal conductivity of pure Ag at 30 K was measured to be 994.0 W/m.K on the other hand the corresponding values of A g0.9995/M g0.0005, A g0.974/A u0.025/M g0.001, A g0.973/Au.0.025//M g0.002, and A g0.92/P d0.06/M g0.02 were 342.6, 62.1, 59.2, 28.9 W/m.K respectively indicating 3 to 30 times lower than that of pure Ag. In addition alloying element additions to Ag improved mechanical strength while reduced elongation probably due to the strengthening mechanisms by the presence of additive atoms.s.

  • PDF

Measurement and Verification of Thermal Conductivity of Multilayer Thin Dielectric Film via Differential 3ω Method (차등 3ω 기법을 이용한 다층 유전체 박막의 열전도도 측정 및 검증)

  • Shin, Sang-Woo;Cho, Han-Na;Cho, Hyung-Hee
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.85-90
    • /
    • 2006
  • In this study, measurement of thermal conductivity of multilayer thin dielectric film has been conducted via differential 3ω method. Also, verification of differential 3ω method has been accomplished with various proposed criteria. The target film for the measurement is 300 nm thick silicon dioxide which is covered with upper protective layer of various thicknesses. The upper protective layer is inserted between the target film and the heater line for purpose of electrical insulator or anti-oxidation barrier since the target film may be a good electrical conductor or a well-oxidizing material. Since the verification of differential 3ω method has not been conducted yet, we have shown that the measurement of thermal conductivity of thin films with upper protective layer via differential 3ω method is verified to be reliable as long as the proposed preconditions of the samples are satisfied. Experimental results show that the experimental errors tend to increase with aspect ratio between thickness of the upper protective layer and width of the heater line due to heat spreading effect.

  • PDF

The Automatic Precision Measurement of RF Voltage using Power and Impedance Standards (전력과 임피던스표준을 이용한 RF전압의 정밀 자동측정)

  • Shin, Jin-Kook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.3A
    • /
    • pp.319-323
    • /
    • 2007
  • In this paper, the automatic precision measurement of RF voltage has been done using the power and impedance standards [1] in the frequency range of 50 to 1000 MHz. A coaxial microcalorimeter and an automatic network analyzer were used for the determination of the RF-DC differences and the total uncertainty is about 1.0 %. A HP computer, a commodore computer and IEEE-488 interface bus were used for measuring the effective efficiency of thermistor mount and the RF-DC difference of thermal voltage converter, All processes of measurement were accomplished by self-developed program automatically.

Effects of Porosity and Water Content on Thermal Conductivity of Soils (토양의 공극률 및 함수비가 열전도도에 미치는 영향)

  • Cha, Jang-Hwan;An, Sun-Joon;Koo, Min-Ho;Kim, Hyoung-Chan;Song, Yoon-Ho;Suh, Myoung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.3
    • /
    • pp.27-36
    • /
    • 2008
  • This paper presents a comprehensive laboratory study that examines the effects of porosity, water content, density and grain size distribution on the thermal conductivity of soils which were sampled from 16 synoptic stations of Korea. The experimental results clearly demonstrate that porosity and water content are important parameters which strongly affect the thermal conductivity of soils. Soils with lower porosities and higher water contents have higher thermal conductivities. On the contrary, increase of the matrix density slightly increases the thermal conductivity, and grain size distribution hardly affects the thermal conductivity. Dry soils with the same porosity tend to have more scattered values of thermal conductivity than wet soils. Based on the experimental results, a multiple linear regression model and a nonlinear regression model, having two regression variables of porosity and water content, were presented to predict thermal conductivity. Both models show a high accuracy of prediction with R2 values of 0.74 and 0.82, respectively. Thus, it is expected that the suggested empirical models can be used for predicting thermal conductivity of soils by measuring porosity and water content.

Change of Surface Temperature in Woodceramics Made from MDF(I) -Effect of Density and Burning Temperature- (MDF로 제조된 우드세라믹의 표면온도변화(I) -밀도 및 소성온도의 영향-)

  • 오승원
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • The following conclusions were obtained with measuring the surface temperature change of woodceramics which were made of MDF to identify usability of using them as a sub-material for heating system when installing Ondol heating floor. For this purpose, woodceramics were burned at the temperature of 650C and 800C 1. Surface temperature of woodceramics increased with the increase of density of woodceramics, but no significant difference was detected at the surface temperature when burning temperature was changed. 2. Surface temperature change under given temperature increased as time passed and it showed more increase in temperature at the burning temperature of 800C. 3. Surface temperature change with the change in floor temperature increased u hen floor temperature increased and heating mechanism was fast with increase of measuring temperature.

  • PDF