• Title/Summary/Keyword: 열발광분석

Search Result 14, Processing Time 0.022 seconds

Physicochemical Quality and Detection Properties of Irradiated Powdered-Soups (감마선 조사된 분말수프의 이화학적 품질과 조사여부 판별특성)

  • Kwak, Ji-Young;An, Yeoung-Eun;Jung, Bo-Yun;Kwon, Joong-Ho
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.2
    • /
    • pp.82-89
    • /
    • 2012
  • Commercial powdered soups, such as potato soup(PS), corn soup(CS), and chicken-herb soup(CHS), were gamma-irradiated at 0, 1, 5 and 10 kGy and subjected to physicochemical evaluation and identification trials by analyzing photostimulated luminescence(PSL), electron spin resonance(ESR), and thermoluminescence(TL). The changes in moisture content and pH of soup samples were negligible upon irradiation. The Hunter's color determinations showed that lightness (L value) decreased and yellowness (b value) increased as the irradiation dose increased in PS sample. The viscosity of irradiated samples was reduced in the order of PS, CS and CHS. The analyses of PSL, ESR and TL were applicable to the identification of irradiated powdered-soups at more than 1 kGy by detecting PSL photon counts/60 sec(over 5000), radiation-induced multicomponents-ESR signal, and typical TL glow curve at $150-250^{\circ}C$.

  • PDF

Quality and Thermoluminescence Properties of ${\gamma}$-Irradiated Boiled-Dried Anchovies during Storage (감마선 조사와 저장 기간에 따른 건멸치류의 품질 및 열발광 특성)

  • 권중호;노정은;변명우
    • Food Science and Preservation
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2002
  • The effect of gamma irradiation was investigated on the microbiological and physicochemical qualities of boiled-dried anchovies (large- and smallsized) packed in PVC film (0.06 ㎜) during storage at 15$\pm$1$\^{C}$ for 6 months. On the other hand, thermoluminescence characteristics of minerals extracted from the sample were analyzed to evaluate its possibility in detecting the irradiated anchovies. The samples were contaminated by microbial levels of 104∼106 CFU/g in total aerobic bacterial counts and negative in coliforms, which were different depending on the sample sizes. Gamma irradiation at 3 kGy was effective for improving the hygienic quality of both samples for 6 months, keeping the microbial population less than 20 CFU/g. Besides it was not detrimental to the quality attributes, such as instrumental color parameters L, a, b, ΔE), browning, TBA value, volatile basic nitrogen, trimethylamine-N and sensory properties(appearance, color, odor, tape, overall acceptability). However, storage conditions (time, temperature, packing) showed a critical factor nfluencing the quality changes of dried anchovies. Thermoluminscence analysis was prove to distinguish irradiated from non-irradiated anchovies by comparing both temperature at which glow curves appear and the curve intensity, that was possible even after 6 months at - 20$\^{C}$.

The Quality and Thermoluminescence Properties of Dried Pollack during Storage Following Irradiation (방사선 조사와 저장기간에 따른 북어의 품질 및 thermoluminescence 특성)

  • Noh, Jung-Eun;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.711-716
    • /
    • 2004
  • Gamma irradiation was applied to dried pollack to improve its microbiological quality and evaluate quality stability of irradiated samples. Thermoluminescence (TL) properties of minerals separated from irradiated samples were measured for possible use in identifying irradiation treatment. Dried pollack was packaged in commercial unit (PVC film, 0.06 mm thickness) and stored at $15{\pm}1^{\circ}C$ for 6 months. Samples showed over $10^4\;CFU/g$ in total aerobic bacteria or yeasts&molds, which increased during storage, reaching $10^6-10^7\;CFU/g$ at 3rd month of storage. Irradiation at 3 kGy was effective for improving hygienic quality for 6 months, keeping microbial population under 20 CFU/g. Gamma irradiation at 3 kGy or less did not significantly influence physicochemical quality attributes, such as browning, TBA value, volatile basic nitrogen, trimethylamine, and sensory properties, whereas storage time remarkably induced quality changes of dried pollack. TL analysis was proved suitable for identifying irradiated from non-irradiated samples over 6 months of storage.

Multistep Identification of γ-Irradiated Boiled-Dried Anchovies by Analysis of Thermoluminescence, Electron Spin Resonance, Hydrocarbon and 2-Alkylcyclobutanone (건멸치의 방사선 조사 확인을 위한 열발광, 전자스핀공명, Hydrocarbon 및 2-Alkylcyclobutanone의 다중분석)

  • 노정은;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.1
    • /
    • pp.8-14
    • /
    • 2003
  • Multistep detection was peformed to identify irradiated dried anchovy. In thermoluminescence (TL) analysis, non-irradiated samples represented a lower peak at about 28$0^{\circ}C$, but irradiated samples showed a higher peak at around 20$0^{\circ}C$. The normalization with a re-irradiation step at 1 kGy could verify the identification results. Electron spin resonance (ESR) spectroscopy for bones separated from irradiated anchovy revealed specific signals (g=2.002,1.998) derived from a hydroxyapatite radical, which intensities were in proportion to the irradiation doses and still detectable even after 6 months of storage at -2$0^{\circ}C$. Six kinds of hydrocarbons (HC) were observed in dried anchovy samples and 1,7-hexadecadiene and 1-hexadecene were only detected in irradiated anchovy at 1 kGy or more. Also among 3 kinds of radiation-induced 2-alkylcyclobutanones (2-ACB) observed, 2-dodecylcy-clobutanone and 2-tetradecylcyclobutanone were unique in irradiated anchovy. As a result, the concentration of radiation-induced HCs and 2-ACBs were dependent on the irradiation dose and detectable after 6 months of storage. However, TL and ESR analyses were found simpler than the other methods for identification of irradiated boiled-dried anchovy.

Identification of irradiated soybean with different processing and origin (대두의 가공특성 및 원산지별 조사처리 판별 연구)

  • Jung, Yoo-Kyung;Lee, Hye-Jin;Lee, Ji-Yeon;Choi, Jang-Duck;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.252-257
    • /
    • 2017
  • In this study, the physicochemical properties of irradiated (gamma-ray and electron-beam) soybeans with different processing (dry and powder) and origins (Korea, China, and USA) were investigated and compared. The results of photostimulated luminescence (PSL) screening indicated that all non-irradiated soybeans showed photon counts (PCs) ${\leq}700$, while all irradiated soybeans showed positive values-gamma-ray 5,815-39,591 count/min; electron beam 5,791-60,055 count/min. The results of thermoluminescence (TL) analysis of all irradiated soybeans indicated that the $TL_1$ glow curves exhibited maximum peaks at 150-250. TL ratio of irradiated samples was ${\geq}0.1$; therefore, the clear identification of irradiated samples was guaranteed by analysis of the $TL_1$ curve shape and TL ratios. The results of electron spin resonance (ESR) signal of 3 irradiated and dried soybeans showed two side peaks mutually spaced at 6.0 mT (cellulose radical). Non-specific signal was detected for all irradiated soybean powders; hence, ESR analysis could not be performed.

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Soybeans (열발광, 전자스핀공명 및 DNA Comet 분석에 의한 대두의 방사선 조사 여부 검지 특성)

  • Lee, Eun-Young;Jeong, Jae-Young;Noh, Jung-Eun;Jo, Deok-Jo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • The detection characteristics of gamma-irradiated $(0{\sim}4\;kGy)$ soybeans produced in Korea and China were investigated by thermoluminescene (TL), electron spin resonance (ESR), and DNA comet assay. The TL glow curves were shown at around $200^{\circ}C$ for irradiated soybeans, while that at $280^{\circ}C$ for the non-irradiated one. The normalization with a re-irradiation step at 1 kGy could verify the above detection results. The Korean soybean showed higher glow curves than Chinese did. The ESR spectroscopy for husks of irradiated soybeans revealed specific signals (g = 2.02374, 1.98715) derived from cellulose radical, which intensities were proportional to irradiation does, with the higher peaks in Chinese sample than Korean one. The DNA comet for the non-irradiated sample showed no or little tails, while those for irradiated samples above 0.5 kGy were remarkably changed in their length, size, and concentration, thus resulting in distinguishing non-irradiated from irradiated samples. As a result, TL, ESR, and DNA comet determinations were found suitable for the detection of irradiated soybean at 0.5 kGy or more, and negligible differences were observed between Korean and Chinese origins in their detection characteristics.

Synthesis and luminescent properties of $Er^{3+}$ doped $CaZrO_3$ long persistent phosphors ($Er^{3+}$를 첨가한 $CaZrO_3$ 축광성 형광체의 합성 및 발광 특성 분석)

  • Park, Byeong-Seok;Choi, Jong-Koen
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Novel long persistent phosphors of $CaZrO_3:Er^{3+}$ have been synthesized by traditional solid state reaction method. The long persistent phosphor crystalline particles were characterized by the X-ray diffraction (XRD), photoluminescence spectrophotometer, thermoluminescence (TL) and luminance meter. The results reveal that the samples are composed of single $CaZrO_3$ phase. The broadband emission spectra of 446 nm peak and 550 nm peak was revealed by synthesized at high temperature in $N_2$ gas. Green long persistent phosphors have been observed in the sys_em for over 6 h after UV irradiation (254 nm). The main emission peak was ascribed to $Er^{3+}$ ions transition from $^5D_{5/2}{\rightarrow}^4F_{9/2},\;^2H_{12/2},\;^4S_{3/2}{\rightarrow}^4I_{13/2}\;and\;^2G_{9/2}{\rightarrow}^4I_{13/2}$, and the afterglow may be ascribed to the suitable trap centers in the $CaZrO_3$ host lattice.

Identification Characteristics of Irradiated Dried Red Pepper during Storage by Analysis of Thermoluminescence, DNA Comet, and DEFT/APC (Thermoluminescence, DNA Comet 및 DEFT/APC 분석에 의한 방사선처리 건고추의 저장 중 검지 특성)

  • Kim, Byeong-Keun;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.851-856
    • /
    • 2004
  • Minerals separated from irradiated dried red pepper (whole) at 2.5 kGy or higher showed typical thermoluminescence (TL) glow curves ($TL_1$) at around $150^{\circ}C$, which increased with irradiation dose. The TL ratio ($TL_1/TL_2$) through re-irradiation step at 1 kGy enhanced reliability of TL identification results. DNA comet assay indicated that the intact cell was observed in non-irradiated pepper (seed), while some long tails were found in irradiated ones, showing relationship between irradiation dose and tail length. Log DEPT/APC values increased in proportion to irradiation doses in powdered and whole peppers. Based on overall results, irradiated dried red peppers could be screened using DNA comet assay or log DEFT/APC, and moreover the identification results were verified by TL analysis.

Effect on Identification of Irradiated Wheat and Soybean by the Full-overlapped Gravitational Field Energy(FGFE) Treatment (중첩중력에너지가 방사선 조사된 밀과 대두의 판별특성에 미치는 영향)

  • Oh, Sang-Lyong;Ahn, Jae-Jun;Kwon, Joong-Ho;Kim, Hak-Je
    • Food Science and Preservation
    • /
    • v.18 no.3
    • /
    • pp.294-301
    • /
    • 2011
  • The aim of this study was to investigate the changes in identification markers of irradiated foods after treatment of the full-overlapped gravitational field energy (FGFE). Wheat and soybean samples were irradiated at 0-5 kGy of Co-60 gamma energy, and analyzed for photostimulated and thermo luminescence characteristics (PSL and TL) and sprouting rate at 0 and 6th month after FGFE treatment. As a screening method for irradiated samples, PSL photon counts (PCs) for the non-irradiated samples appeared negative (<700 PCs), while irradiated samples gave positive (>5,000 PCs). But FGFE-treated irradiated samples appeared intermediate (700-5,000 PCs), showing decreased PCs during storage. The TL analysis on irradiated samples exhibited glow curve peaks in range of $150-200^{\circ}C$ and TL ratio ($TL_1/TL_2$) was also >0.1. Therefore, identification of irradiated samples was possible using thermoluminescence. But the glow curve range of FGFE-treated irradiated samples shifted from $150-200^{\circ}C$ to $180-230^{\circ}C$ and TL intensity was decreased 37-60% resulting from FGFE treatment. After 6 months of storage, all the samples showed a decrease in TL intensity, but identification was still possible. The sprouting rate of irradiated samples decreased by about 72%, whereas that of FGFE-treated irradiated samples showed by about 85%, as compared to non-irradiated samples. More detailed study is required to investigate sprouting phenomena for FGFE-treated samples.

The Detection of Irradiated Composite Seasoning Foods by Analyzing Photostimulated Luminescence (PSL), Electron Spin Resonance (ESR) and Thermoluminescence (TL) (PSL, ESR 및 TL 측정에 의한 복합조미식품의 방사선 조사여부 검지)

  • Kwon Joong-Ho;Kim Mi-Yeung;Kim Byeong-Keun;Chung Hyung-Wook;Kim Tae-Cheol;Kim Soo-Jin
    • Food Science and Preservation
    • /
    • v.13 no.1
    • /
    • pp.55-60
    • /
    • 2006
  • Two kinds of composite seasoning products (beef broth powder, polk bone extract powder) were used for a detection trial of gamma irradiation treatment up to 10 kGy by analyzing photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence(TL). PSL results showed that the photon counts of non-irradiated samples were lower than 700, while those of irradiated samples were higher than 5000, which makes it possible to screen irradiated composite seasoning products at 1 kGy or over from the non-irradiated control. ESR signals measured for both irradiated samples were not irradiation-specific, even though they were dose dependent in the signal intensity. Radiation-induced TL glow curves were found in irradiated beef broth powder and furthernmore, TL ratio $(TL_4/TL_2)$ obtained by a re-irradiation step could verify the detection result of TL1 glow curves, showing ratios lower than 0.05 in the non-irradiated sample and higher than 1.00 in irradiated ones.