• Title/Summary/Keyword: 연속적 개발

Search Result 1,745, Processing Time 0.027 seconds

Study(V) on Development of Charts and Equations Predicting Allowable Compressive Bearing Capacity for Prebored PHC Piles Socketed into Weathered Rock through Sandy Soil Layers - Analysis of Results and Data by Parametric Numerical Analysis - (사질토를 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연속 연구(V) - 매개변수 수치해석 자료 분석 -)

  • Park, Mincheol;Kwon, Oh-Kyun;Kim, Chae Min;Yun, Do Kyun;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.10
    • /
    • pp.47-66
    • /
    • 2019
  • A parametric numerical analysis according to diameter, length, and N values of soil was conducted for the PHC pile socketed into weathered rock through sandy soil layers. In the numerical analysis, the Mohr-Coulomb model was applied to PHC pile and soils, and the contacted phases among the pile-soil-cement paste were modeled as interfaces with a virtual thickness. The parametric numerical analyses for 10 kinds of pile diameters were executed to obtain the load-settlement relationship and the axial load distribution according to N-values. The load-settlement curves were obtained for each load such as total load, total skin friction, skin friction of the sandy soil layer, skin friction of the weathered rock layer and end bearing resistance of the weathered rock. As a result of analysis of various load levels from the load-settlement curves, the settlements corresponding to the inflection point of each curve were appeared as about 5~7% of each pile diameter and were estimated conservatively as 5% of each pile diameter. The load at the inflection point was defined as the mobilized bearing capacity ($Q_m$) and it was used in analyses of pile bearing capacity. And SRF was appeared above average 70%, irrespective of diameter, embedment length of pile and N value of sandy soil layer. Also, skin frictional resistance of sandy soil layers was evaluated above average 80% of total skin frictional resistance. These results can be used in calculating the bearing capacity of prebored PHC pile, and also be utilized in developing the bearing capacity prediction method and chart for the prebored PHC pile socketed into weathered rock through sandy soil layers.

Blended IT/STEM Education for Students in Developing Countries: Experiences in Tanzania (개발도상국 학생들을 위한 블랜디드 IT/STEM교육: 탄자니아에서의 경험 및 시사점)

  • Yoon Rhee, Ji-Young;Ayo, Heriel;Rhee, Herb S.
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.151-162
    • /
    • 2020
  • Education is one of the priority sectors specified in Tanzania, and it has committed to provide 11 years of compulsory free basic education for all from pre-primary to lower secondary level. Despite the Government's efforts to provide free basic education to all children, there are 2.0 million (23.2 per cent) out of 8.5 million children at the primary school age of 7-13, who are out of school in Tanzania. The ICT class should be offered as a regular class in all secondary schools in Tanzania, recommended by the ministry of education. However, many schools are struggling to implement this mandate. Most of schools offer the ICT class with theory without any real hardware. Some schools were given with computers but they were not maintained for operation. There is a huge task to make ICT education universal. Main issues include: remoteness (off-grid area), lack of ICT teachers, lack of resources such as hardware, infrastructure, and lack of practical lessons or projects to be used at schools. An innovative blended ICT/STEM education program is being conducted not only for Tanzanian public and private/international schools, but also for out-of-school adolescents through institutions, NGO centers, home visits and at the E3 Empower academy center. For effective STEM education to take place and remain sustainable, more practical curriculum, and close-up teacher support need to be accompanied concurrently. Practical, project-based simple coding lessons have been developed and employed that students experience true learning. The effectiveness of the curriculum has been demonstrated in various project centers, and it showed that students are showing new interests in exploring new discovery, even though this was a totally new area for them. It has been designed for an easy replication, thus students who learned can repeat the lessons themselves to other students. The ultimate purpose of this project is to have IT education offered as universally as possible throughout the whole Tanzania. Quality education for all children is a key for better future for all. Previously it was hoped that education with discipline will improve the active learning. But now more than ever, we believe that children have the ability to learn on their own with given proper STEM education tools, guidelines and environment. This gives promising hope to all of us, including those in the developing countries.

Prophylactic cranial irradiation in limited small-cell lung cancer : incidence of brain metastasis and survival and clinical aspects (예방적 두강내 방사선 조사후 소세포 폐암 환자의 뇌전이 빈도와 생존율에 대한 연구)

  • Suh, Jae-Chul;Kim, Myung-Hoon;Park, Hee-Sun;Kang, Dong-Won;Lee, Kyu-Seung;Ko, Dong-Seok;Kim, Geun-Hwa;Jeong, Seong-Su;Cho, Moon-June;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.323-331
    • /
    • 2000
  • Purpose: Brain metastases are present in approximately 10-16% of small cell lung cancer patients at diagnosis. Brain metastasis is an important clinical problem associated with increasing the survival rate, with a cumulative incidence of up to 80% in patients surviving 2 years. Prophylactic cranial irradiation(PCI) reduces the incidence of brain matastasis and may prolong survival in patients with limited small-cell lung cancer who achieved complete remission. This study was performed to analyze the incidence of brain metastasis, survival and clinical aspects after PCI in patients with limited small-cell lung cancer who achieved complete remission. Methods : Between 1989 and 1999, forty-two patients with limited small-cell lung cancer who achived achieved complete remission after therapy were enrolled into this study retrospectively. All patients received etoposide and cisplatin(VPP) alternating with cytoxan, adriamycin, and vincristine(CAV) every 3 weeks for at least 6 cycles initially. All patients received thoracic radiotherapy: concurrent(38.1%) and sequential(61.9%). All patients received late PCI. Results : Most patients(88.1%) were men, and the median age was 58 years. The median follow-up duration was 18.1 months. During the follow-up period, 57.1% of the patients developed relapse. The most frequent site of relapse was chest(35.7%), followed by brain(14.3%), liver(11.9%), adrenal gland(44%), and bone(2.2%). With the Kaplan-Meier method, the average disease-free interval was 1,090 days(median 305 days). The average time to development of brain relapse after PCI and other sites relapse(except brain) were 2,548 days and 1,395 days(median 460 days), respectively. The average overall survival was 1,233 days(median 634 days, 21.1 months), and 2-year survival rates was 41.7%. The average overall survival in the relapse group was 642 days(median 489 days) and in the no relapse group was 2,622 days(p<0.001). The average overall survival in the brain relapse group was 928 days(median 822 days) and in the no brain relapse group was 1,308 days(median 634 days)(p=0.772). In most patients(85.7%), relapse(except brain) or systemic disease was the usual cause of death. Brain matastasis was the cause of death in 14.3% of the cases. Conclusions : We may conclude that PCI reduces and delays brain metastasis in patients with limited small cell lung cancer who achieved complete remission. We found decreased survival in relapse group but, no significant survival difference was noted according to brain matastasis. And relapse(except brain) or systemic disease was the usual cause of death. In order to increase survival, new treatment strategies for control methods for relapse and systemic disease are required.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Preliminary Report of the $1998{\sim}1999$ Patterns of Care Study of Radiation Therapy for Esophageal Cancer in Korea (식도암 방사선 치료에 대한 Patterns of Care Study ($1998{\sim}1999$)의 예비적 결과 분석)

  • Hur, Won-Joo;Choi, Young-Min;Lee, Hyung-Sik;Kim, Jeung-Kee;Kim, Il-Han;Lee, Ho-Jun;Lee, Kyu-Chan;Kim, Jung-Soo;Chun, Mi-Son;Kim, Jin-Hee;Ahn, Yong-Chan;Kim, Sang-Gi;Kim, Bo-Kyung
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.79-92
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: For the first time, a nationwide survey in the Republic of Korea was conducted to determine the basic parameters for the treatment of esophageal cancer and to offer a solid cooperative system for the Korean Pattern of Care Study database. $\underline{Materials\;and\;Methods}$: During $1998{\sim}1999$, biopsy-confirmed 246 esophageal cancer patients that received radiotherapy were enrolled from 23 different institutions in South Korea. Random sampling was based on power allocation method. Patient parameters and specific information regarding tumor characteristics and treatment methods were collected and registered through the web based PCS system. The data was analyzed by the use of the Chi-squared test. $\underline{Results}$: The median age of the collected patients was 62 years. The male to female ratio was about 91 to 9 with an absolute male predominance. The performance status ranged from ECOG 0 to 1 in 82.5% of the patients. Diagnostic procedures included an esophagogram (228 patients, 92.7%), endoscopy (226 patients, 91.9%), and a chest CT scan (238 patients, 96.7%). Squamous cell carcinoma was diagnosed in 96.3% of the patients; mid-thoracic esophageal cancer was most prevalent (110 patients, 44.7%) and 135 patients presented with clinical stage III disease. Fifty seven patients received radiotherapy alone and 37 patients received surgery with adjuvant postoperative radiotherapy. Half of the patients (123 patients) received chemotherapy together with RT and 70 patients (56.9%) received it as concurrent chemoradiotherapy. The most frequently used chemotherapeutic agent was a combination of cisplatin and 5-FU. Most patients received radiotherapy either with 6 MV (116 patients, 47.2%) or with 10 MV photons (87 patients, 35.4%). Radiotherapy was delivered through a conventional AP-PA field for 206 patients (83.7%) without using a CT plan and the median delivered dose was 3,600 cGy. The median total dose of postoperative radiotherapy was 5,040 cGy while for the non-operative patients the median total dose was 5,970 cGy. Thirty-four patients received intraluminal brachytherapy with high dose rate Iridium-192. Brachytherapy was delivered with a median dose of 300 cGy in each fraction and was typically delivered $3{\sim}4\;times$. The most frequently encountered complication during the radiotherapy treatment was esophagitis in 155 patients (63.0%). $\underline{Conclusion}$: For the evaluation and treatment of esophageal cancer patients at radiation facilities in Korea, this study will provide guidelines and benchmark data for the solid cooperative systems of the Korean PCS. Although some differences were noted between institutions, there was no major difference in the treatment modalities and RT techniques.