• Title/Summary/Keyword: 연성축

Search Result 171, Processing Time 0.024 seconds

A Coupled Unbalance Response Analysis of Geared Two-Shaft Rotor-Bearing System (2축 로터-베어링 시스템의 연성 불균형 응답해석)

  • 이안성;하진웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.220-226
    • /
    • 2002
  • A general solution method is presented to obtain the unbalance response orbit from the finite element based equations of motion of a gear-coupled two-shaft rotor-bearing system. Particularly, are proposed the analytical solutions of major and minor axis radii of the orbit. The method has been applied to analyze the unbalance response of a 800 refrigeration-ton turbo-chiller rotor-bearing system, having a bull-pinion speed increasing gear. The bumps of unbalance responses have been observed at the first torsional natural frequency due to the coupling of lateral and torsional dynamics by the gear meshing. Further, the proposed analytical solutions have been validated with results obtained by a full numerical approach.

  • PDF

Evaluation and Design of Mngine Mounts by Making use of Computer (전산을 이용한 엔진지지계의 평가 및 설계)

  • 김동우;조청훈
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.17-27
    • /
    • 1987
  • 최근 자동차기술의 발달로 인한 차량의 경량화, 고급화 추세는 더욱 개선된 승차감을 요구하고 있다. 승차감에 영향을 미치는 주요인으로서는 엔진의 진동과 소음, 변속장치, 구동축 등의 구동 계통의 진동 및 소음, 그리고 노면으로부터의 진동, 외부 공기의 흐름에 의한 소음 등 여러가지가 있다. 엔진지지계는 이중 엔진의 진동 및 소음을 절연하는 기능을 맡고 있고 동시에 엔진하중의 지지, 변위제한, 충격흡수 등의 기능도 가지고 있다. 실제에 있어서 엔진지지계는 진동 및 소음 절연의 기능 외에 다른 기능도 갖고 있으나 이중 가장 어렵고 해석이 곤란한 것은 결국 진동절 연성능이라고 할 수 있다. 그러나 여러 가지 제약조건이 있으므로 최적의 진동절연특성의 실 현이 항상 가능한 것은 아니고 방진고무의 특성치난 지지각도 등의 어느 범위안에서만 선택이 가능하므로 실제 설계에 있어서는 적용상의 특정조건을 만족시키는 초기설계치를 정하여 그때의 진동절연특성을 평가하고 기준이하일때는 설계치를 재조정하여 다시 평가하는 접근방식이 실질 적이다. 따라서 이 설계과정에 필요한 엔진지지계의 진동절연특성해석 및 평가용 컴퓨터 프로 그램을 개발하였으며 그 해석치와 실험결과를 비교하여 타당성을 입증하였다.

  • PDF

A Study on the Vibration Analysis of Spindle Housing with High Strength Aluminum of 2NC Head in Five-axis Cutting Machine Training (5축 절삭가공기 교육 중 2NC 헤드의 고강도 알루미늄을 적용한 스핀들 하우징의 극한 조건의 진동해석에 관한 연구)

  • Lee, Ji Woong
    • Journal of Practical Engineering Education
    • /
    • v.14 no.1
    • /
    • pp.119-125
    • /
    • 2022
  • Materials used for education are materials such as SM20C, Al6061, and acrylic. SM20C materials are carbon steel and are often used in certification tests and functional competitions, but are also widely used in industrial sites. The Al6061 material is said to be a material that has lower hardness and stronger flexibility than carbon steel, so it is a material that generates a lot of compositional selection of tools. If students are taught practical training using acrylic materials, vibration occurs due to excessive cutting in some parts and damage to the tool occurs. In this process, we examine to what extent the impact on the 2NC head, which is a five-axis equipment, can affect precision control. The weakest part of the five-axis equipment can be said to be the weakest part of the head that controls the AC axis. When the accuracy and cumulative tolerance of this part occur, the accuracy of all products decreases. Therefore, the core part of the 2NC head, the spindle housing, was carried out using an Al7075 T6 (Alcoa, USA) material. In the process of vibration and cutting applied to this material, the analysis was conducted to find out the value applied to the finite element analysis under extreme conditions. It is hoped that this analysis data will help students see and understand the structure of 5-axis machining rather than 5-axis cutting.

Deformation History of Precambrian Metamorphic Rocks in the Yeongyang-Uljin Area, Korea (영양-울진 지역 선캠브리아기 변성암류의 변형작용사)

  • Kang Ji-Hoon;Kim Nam Hoon;Park Kye-Hun;Song Yong Sun;Ock Soo-Seok
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.179-190
    • /
    • 2004
  • Precambrian metamorphic rocks of Yeongyang-Uljin area, which is located in the eastern part of Sobaegsan Massif, Korea, are composed of Pyeonghae, Giseong, Wonnam Formations and Hada leuco granite gneisses. These show a zonal distribution of WNW-ESE trend, and are intruded by Mesozoic igneous rocks and are unconformably overlain by Mesozoic sedimentary rocks. This study clarifies the deformation history of Precambrian metamorphic rocks after the formation of gneissosity or schistosity on the basis of the geometric and kinematic features and the forming sequence of multi-deformed rock structures, and suggests that the geological structures of this area experienced at least four phases of deformation i.e. ductile shear deformation, one deformation before that, at least two deformations after that. (1) The first phase of deformation formed regional foliations and WNW-trending isoclinal folds with subhorizontal axes and steep axial planes dipping to the north. (2) The second phase of deformation occurred by dextral ductile shear deformation of top-to-the east movement, forming stretching lineations of E-W trend, S-C mylonitic structure foliations, and Z-shaped asymmetric folds. (3) The third phase deformation formed I-W trending open- or kink-type recumbent folds with subhorizontal axes and gently dipping axial planes. (4) The fourth phase deformation took place under compression of NNW-SSE direction, forming ENE-WSW trending symmetric open upright folds and asymmetric conjugate kink folds with subhorizontal axes, and conjugate faults thrusting to the both NNW and SSE with drag folds related to it. These four phases of deformation are closely connected with the orientation of regional foliation in the Yeongyang-Uljin area. 1st deformation produced regional foliation striking WNW and steeply dipping to the north, 2nd deformation locally change the strike of regional foliation into N-S direction, and 3rd and 4th deformations locally change dip-angle and dip-direction of regional foliation.

Modified Equation for Ductility Demand Based Confining Reinforcement Amount of RC Bridge Columns (철근콘크리트 교각의 소요연성도에 따른 심부구속철근량 산정식 수정)

  • Lee, Jae-Hoon;Son, Hyeok-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.169-178
    • /
    • 2009
  • An equation for calculating confining reinforcement amount of RC bridge columns, specified in the current bridge design codes, has been made to provide additional load-carrying strength for concentrically loaded columns. The additional load-carrying strength will be equal to or slightly greater than the resistant strength of a column against axial load, which is lost because the cover concrete spalls off. The equation considers concrete compressive strength, yield strength of transverse reinforcement, and the section area ratio as major variables. Among those variables, the section area ratio between the gross section and the core section, varying by cover thickness, is a variable which considers the strength in the compression-controlled region. Therefore, the cross section ratio does not have a large effect in the aspect of ductile behavior of the tension-controlled region, which is governed by bending moment rather than axial force. However, the equation of the design codes for calculating confining reinforcement amount does not directly consider ductile behavior, which is an important factor for the seismic behavior of bridge columns. Consequently, if the size of section is relatively small or if the section area ratio becomes excessively large due to the cover thickness increased for durability, too large an amount of confining reinforcement will be required possibly deteriorating the constructability and economy. Against this backdrop, in this study, comparison and analysis were performed to understand how the cover thickness influences the equation for calculating the amount of confining reinforcement. An equation for calculating the amount of confining reinforcement was also modified for reasonable seismic design and the safety. In addition, appropriateness of the modified equation was examined based on the results of various test results performed at home and abroad.

Design of Sensor Network for Estimation of the Shape of Flexible Endoscope (연성 대장내시경의 형상추정을 위한 센서네트워크의 설계)

  • Lee, Jae-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.299-306
    • /
    • 2016
  • In this paper, a method of shape prediction of an endoscope handling robot that can imitate a surgeon's behavior using a sensor network is suggested. Unit sensors, which are composed of a 3-axis magnetometer and 3-axis accelerometer pair comprise the network through CAN bus communication. Each unit of the sensor is used to detect the angle of the points in the longitudinal direction of the robot, which is made from a flexible tube. The signals received from the sensor network were filtered using a low pass Butterworth filter. Here, a Butterworth filter was designed for noise removal. Finally, the Euler angles were extracted from the signals, in which the noise was filtered by the low path Butterworth filter. Using this Euler angle, the position of each sensor on the sensor network is estimated. The robot body was assumed to consist of links and joints. The position of each sensor can be assumed to be attached to the center of each link. The position of each link was determined using the Euler angle and kinematics equation. The interpolation was carried out between the positions of the sensors to be able to connect each point smoothly and obtain the final posture of the endoscope in operation. The experimental results showed that the shape of the colonoscope can be visualized using the Euler angles evaluated from the sensor network suggested and the shape of serial link estimated from the kinematics chain model.

Plastic Hinge Length of Reinforced Concrete Columns with Low Height-to-Width Ratio (전단경간비가 작은 철근콘크리트 기둥의 소성힌지 길이)

  • Park, Jong-Wook;Woo, Jae-Hyun;Kim, Byung-Il;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.675-684
    • /
    • 2010
  • The reinforced concrete members are designed to fail in flexural to lead ductile fracture. In the building structures, the failure is typically imposed on beams to prevent damages in columns. However, progression of plastic collapse mechanism may ultimately develop, a plastic hinge at the bottem end of the first floor column, which then can be subjected to shear or bond finally due to large axial force and small shear span-to-depth ratio. In this study, 10 RC column specimens failed in shear after flexural yielding was investigated to determine the factors affecting the plastic hinge length. The findings of this study showed that the most effective factor affecting the plastic hinge length was an axial force. As an axial force increase, an axial strain and a ductility ratio were decreased obviously. The test also shows the observed plastic hinge length was about 0.8~1.2d and the this result has difference compared with forward research.

Evaluation of Seismic Performance of Prefabricated Bridge Piers with a Circular Solid Section (중실원형단면 조립식 교각의 내진 성능 평가)

  • Kim, Hyun-Ho;Shim, Chang-Su;Chung, Chul-Hun;Kim, Cheol-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.23-31
    • /
    • 2007
  • Fast bridge construction has been increasingly needed according to the changed construction environment. This paper deals with quasi-static tests on precast piers for bridge substructures. One of the most crucial aspect of the design of precast prestressed concrete bridge piers is the seismic performance. Seven precast pier elements were fabricated. The amount of prestressing bars, the prestressing force, and the location and number of the joint between segments were the main test parameters. Test results showed that the introduced axial prestress made the restoration of the deformation under small lateral displacement and minor damage. However, there was no effect of the prestress when the plastic hinge region was damaged severely due to large lateral displacement. Judging from the observed damage, the design of the joints in precast piers should be done for the first joint between the foundation and the pier segment. The amount of the necessary prestressing steel may be designed to satisfy the P-M diagram according to the service loads, not by having the same steel ratio as normal RC bridge piers. In order to satisfy the current required displacement ductility, it is necessary to have the same amount of the transverse reinforcements as RC piers. As the steel ratio increases, the energy absorption capacity increases. The number of joints showed a little influence on the energy absorption capacity.

A Study on the Cutting Pattern Generation of the Membrane Structures Using Triangular Re-mesh (막 구조물의 삼각형 Re-mesh 패턴을 적용한 재단도 생성에 관한 연구)

  • Jeon, Jin-Hyung;Shon, Su-Deok;Jeong, Eul-Seok;Kim, Seung-Deog
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.153-165
    • /
    • 2007
  • Flexible structure uses a material with strong axial stiffness and small bending stiffness as its major structural material so it is very sensitive to initial stiffness. Therefore, the self-formation process which accomplishes a form in the natural world is grasped and it is as well investigated and classified the type of modeling techniques which are available to find the shapes of soft structures. Accordingly, for analysis and design of flexible structure, three-step analysis such as shape analysis, stress-deformation analysis, cutting pattern generation and constructional analysis is required unlike the existing stiff structure. In this study, suggest that minimize the error of side curvatures by the triangle Re-mesh pattern and draw the cutting pattern generation.

  • PDF

Shear Strain Big-Bang of RC Membrane Panel Subjected to Shear (순수전단이 작용하는 RC막판넬의 전단변형률 증폭)

  • Jeong, Je Pyong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.101-110
    • /
    • 2015
  • Recently, nine $1397{\times}1397{\times}178mm$ RC panels were tested under in-plane pure-shear monotonic loading condition using the Panel Element Tester by Hsu (1997, ACI). By combining the equilibrium, compatibility, and the softened stress-strain relationship of concrete in biaxial state, Modern Truss Model (MCFT, RA-STM) are capable of producing the nonlinear analysis of RC membrane panel through the complicated trial-and-error method with double loop. In this paper, an efficient algorithm with one loop is proposed for the refined Mohr compatibility Method based on the strut-tie failure criteria. This algorithm can be speedy calculated to analyze the shear history of RC membrane element using the results of Hsu test. The results indicate that the response of shear deformation energy at Big Bang of shear strain significantly influenced by the principal compressive stress-strain (crushing failure).