• Title/Summary/Keyword: 연성접착제

Search Result 10, Processing Time 0.022 seconds

Characteristics of Reliability for Flip Chip Package with Non-conductive paste (비전도성 접착제가 사용된 플립칩 패키지의 신뢰성에 관한 연구)

  • Noh, Bo-In;Lee, Jong-Bum;Won, Sung-Ho;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.4
    • /
    • pp.9-14
    • /
    • 2007
  • In this study, the thermal reliability on flip chip package with non-conductive pastes (NCPs) was evaluated under accelerated conditions. As the number of thermal shock cycle and the dwell time of temperature and humidity condition increased, the electrical resistance of the flip chip package with NCPs increased. These phenomenon was occurred by the crack between Au bump and Au bump and the delamination between chip or substrate and NCPs during the thermal shock and temperature and humidity tests. And the variation of electrical resistance during temperature and humidity test was larger than that during thermal shock test. Therefore it was identified that the flip chip package with NCPs was sensitive to environment with moisture.

  • PDF

Establishment for Failure Criterion of Adhesively Bonded Joint (접착이음의 파괴 기준 설정을 위한 연구)

  • 이강용;공병석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.183-190
    • /
    • 2000
  • The objective of this work is to develop a criterion for predicting the failure strength of the joints bonded by ductile adhesives. To obtain a criterion, first, fracture tests were carried out for T-peel joint and Single-lap joint with widely differing joints geometries. Then using the fracture loads obtained at tests, the finite element analysis were performed, in which the stresses in the adhesive bonds were calculated in great detail. After examining four epoxy adhesives, it is concluded that the fracture of adhesively bonded joint occurs when the maximum of the ratio of the mean to effective stresses exceeds a constant value which can be determined from analysis and test for each adhesive.

  • PDF

An Experimental Study on Flexural Performance Evaluation of C-Shaped Steel-Timber Composite Beams (C형 강재-목재 합성보의 휨성능 평가에 관한 실험 연구)

  • Oh, Keunyeong;Lee, Sang-Sup;Park, Keum-Sung;Boo, Yoon-Seob
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.331-341
    • /
    • 2024
  • In this study, the flexural strength and ductility of steel-timber composite beams were evaluated to enhance the structural performance of glued-laminated timber beams. Three specimens were fabricated, including one reference glulam beam and two composite beams. The composite beams were constructed by attaching steel sections to the glulam beam using either liquid adhesive or screws. The experimental results showed that the structural performance of the steel-timber composite beams was approximately 2-3 times higher than the reference glulam beam, indicating that both flexural strength and ductility were sufficiently ensured. Notably, the specimen constructed with liquid adhesive demonstrated superior structural performance compared to the screw-attached specimen.

Bond and Flexural Behavior of RC Beams Strengthened Using Ductile PET (고연성 PET 섬유로 보강된 철근콘크리트 보의 부착 및 휨 거동)

  • Park, Hye-Sun;Kim, So-Young;Lim, Myung-Kwan;Choi, Donguk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.30-39
    • /
    • 2016
  • An experimental study was performed to investigate flexural performance and bond characteristics of RC beams strengthened using ductile polyethylene terephthalate(PET) with low elastic modulus. Bond tests were planned and completed following CSA S806. Test variables were fiber type and fiber amount. Also, total of 8 RC beams was tested. Major test variables of the beam tests included section ductility(${\mu}=3.4$, 7.0), fiber type(CF, GF, PET) and amount of fiber strengthening. Moment-curvature analyses of the beam sections were also performed. In bond tests, the bond stress distribution as well as the maximum bond stress increased with increasing amount of PET. In case of 10 layers of PET, the effective bond length was 60 mm with the maximum and the average bond stress of 2.33 and 2.10 MPa, respectively. RC beam test results revealed that the moment capacity of the RC beams strengthened using PET 10 and 20 layers increased over the control beam with little reduction in ductility by fiber strengthening. All beams strengthened using PET resulted in ductile flexural failure without any sign of fiber debonding or fiber rupture. It was important to include the mechanical properties of adhesive in the moment-curvature analysis of PET-strengthened beam sections.

Lifetime Estimation for FPCB of Slide mobile phone (슬라이드형 휴대폰 FPCB(Flexible Printed Circuit Board)의 수명예측)

  • Choi, Jin-Young;Chang, Seog-Weon;Kwack, Kae-Dal
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1283-1288
    • /
    • 2008
  • The FPCB is used as the important component of the sliding mechanism of mobile phones. FPCB have been used as jumper cables(fixed wiring) in various types of circuits because of their flexibility and bending property. The dominant failure mode of the FPCB is open that was caused by fatigue. The fatigue is repeated whenever the sliding is open, so it is a mainly cause of FPCB fatigue. We examined the bending-fatigue lifetime of FPCB. we focused on observing the contact resistance degradation of FPCB of mobile phones according to different test condition of bending strain. As a result, it has proved that lifetime decreased by increasing bending strain.

  • PDF

An Experimental Study on the Shear Behavior of Reinforced Concrete Beams Strengthened with Slit Type Steel Plates (Slit형(形) 강판으로 보강(補强)한 철근콘크리트 보의 전단거동에 관한 실험연구)

  • Lee, Choon-Ho;Shim, Jong-Seok;Kwon, Ki-Hyuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • RC beam of existing structures often encounter shear problems for various reasons. The shear failure of RC beam is sudden and brittle. Strengthening technique jacketing with external bonding of steel plates(or CFRP and CFS) with epoxy is many use to in practice. This study presents test results on strengthening shear deficient RC beams by external bonding of slit type steel plates. Test parameters are width, interval, length, thickness and angle of slit in steel plates. The purpose was to evaluate the reinforcing effects, failure modes and shear capacities for RC beams of strengthened with various slit type steel plates. The test result confirmed that all slit steel plates improved the stiffness and strength of the specimens significantly. Failure modes of SV series and SD series showed shear fractures and flexure fractures at ultimate state respectively. SD series were ductile rather than SV series.

Flexural Behavior of Hybrid Fiber Reinforcement Strengthened RC Beams (하이브리드 섬유보강재로 보강된 철근콘크리트 보의 휨거동)

  • Yi, Seong-Tae;Lee, Chin-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.79-86
    • /
    • 2010
  • This study was performed to evaluate the flexural behavior of Hybrid fiber sheet (HFC) and Hybrid fiber bar (HFB) strengthened reinforced concrete (RC) beams. According to test results, Hybrid fiber reinforcement strengthened RC beams showed approximately 60 to 200% higher reinforcing effects than that of un-reinforced specimens. In addition, the reinforced beams showed the ideal failure pattern, which is failed presenting the ductile behavior after yielding of the reinforcing bar. More specifically, in the case of HFB reinforced RC beams, the difference with puttying method was not apparent since HFB beams reinforced using the injection of epoxy and bonding of putty showed the similar failure patterns.

Confined Effect of Concrete Compressive Members Strengthened with Carbon Fiber Laminate (탄소섬유판으로 횡보강된 콘크리트 압축부재의 보강성능)

  • Chung, Lan;Lee, Hee-Kyoung;Kim, Sung-Chul;Yoo, Seong-Hoon;Kim, Joong-Koo
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.345-352
    • /
    • 1998
  • Compressive strength of concrete compression members strengthend with carbon fiber laminate(CFL) were studied from the test results. Test parameters are spacing, thickness, width, ply and spliced length of carbon fiber laminates. Specimens strength with sheets failed with sudden tensile rupture of the laminate, which indicate very brittle failure mode. Test result shows that closer spacing and to increas thickness of CFL is more effective. But strengthening ratio with 1-ply CFL is more effective than that of specimen with 2-ply CFL. Compressive strength capacity of specimen splied 24cm shows almost similar strength to that of non-spliced specimen. The ultimate load carrying of specimen strengthened with CFL ranges 1.11~1.86 times of that of non-strengthened specimen.

Structural Behavior of Pre-loaded RC Beams Strengthened by SP, CFS, and CFL (재하상태에서 보강된 철근 콘크리트보의 보강 재료에 따른 구조적 거동)

  • Chung, Lan;Lee, Young-Jea;Moon, Heui-Jeung;Lee, Kyung-Un;Jung, Sang-Jin
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.201-208
    • /
    • 1999
  • In recent years, strengthening by steel plate, carbon fiber sheets, and carbon fiber laminate is spotlighted in order to repair and rehabilitation of R/C structures. In this study, 3 methods of rehabilitation technique were analyzed from the test results. Test parameters were the width of cracks, the method of repair and rehabilitation, the magnitude of pre-load. Deflections, failure loads, strains of reinforcing bar, strains of carbon fiber sheet, carbon fiber laminate and steel plate were measured during the tests. The primary purpose of this research was to analyze the failure mode and structural behavior of strengthened RC beams with/without superimposed pre-load. Test results should that no significant difference was observed between with pre-loaded specimens and no-loaded specimens during rehabilitation.

Measuring and Correcting The Compressive Axial Strain of Concrete Cylinders Retrofitted by External Jackets (외부자켓에 의해 보강된 콘크리트 압축시편의 압축변형률 측정 및 보정)

  • Choi, Eun-soo;Lee, Young-Geun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.215-222
    • /
    • 2009
  • In this study, steel and FRP jackets are used to confine concrete cylinders. The FRP jacket behaviors compositely with concrete since there is bonding between them. However, the used steel jacket in this study do not behavior compositely with concrete since there is not an adhesive between them. The steel jackets are attached by external forces and the welding. This study suggests the measuring method of the axial strain for the confined concrete cylinders showing noncomposite behavior with the jackets and the correcting method of the measured strain for the composite-behavior jackets. For the noncomposite-behavior steel jacket, the axial strain of the steel surface does not represent the axial strain of the concrete inside. Also, a compressormeter can not be used. Thus, the two rigid plates at the top and bottom of a cylinder are placed and the distance of the two plates are measured and used for estimating the axial strain of the concrete. For the composite-behavior FRP jacket, the vertical strain measured on the FRP surface can be used for estimating the axial strain of the concrete. However, the vertical strain on the FRP surface contains the tensile strain due to the bulge of the concrete and, thus, the tensile strain should be corrected from the vertical strain. The corrected verticals strains compared with the measured strain or a existing constitute model; the result is satisfactory. The uncorrected stress-strain curves have the potential to under estimate the ductile behavior and the energy-dissipation-capacity of the composite-behavior FRP jackets.