• Title/Summary/Keyword: 연기발생량

Search Result 125, Processing Time 0.024 seconds

The Study on Minimum Smoke Propellant to Reduce Afterburning Reaction (후연소 반응이 감소된 무연계 고체 추진제에 관한 연구)

  • Yim, Yoojin;Lee, Jongseop;Park, Euiyong;Choi, Sunghan;Yoo, Jichang;Cho, Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.10-17
    • /
    • 2013
  • This paper describes a study on after-burning suppressant in a solid propellant to reduce the plume formed outside of rocket nozzles, which could expose the launch site and the flight track. The minimum smoke propellant to enhance the stealth ability was formulated in terms of the kinds and the effects of after-burning suppressant on the ballistic performance and the amount of primary smoke. A after-burning suppressant, $K_2SO_4$ of about 1.1% weight content was found to show profound reduction of the rocket plume, giving negligibly slight increase in pressure exponent of burning rate. Also minimum smoke propellant with less than 1.1% of $K_2SO_4$ corresponds to A-class satisfaction in primary smoke by AGARD standard.

Evaluation Water Resources according to Construction of Multifunctional Administrative City (행정중심복합도시 건설에 따른 장래 수자원 평가)

  • Kang, Shin-Uk;Ko, Ick-Hwan;Hawng, Man-Ha;Lee, Sang-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1627-1631
    • /
    • 2009
  • 정부에서는 수도권 집중 완화와 지역 균형발전의 일환으로 2005년 5월 24일 충남 연기군 남면, 금남면, 동면 및 공주시 장기면 일대 약 $73km^2$에 행정중심복합도시 건설계획을 확정 발표하였다. 이에 따라 신도시 건설이 완료되면 이 지역에 20$\sim$50만명의 인구가 유입될 것으로 전망하고 있다(건설교통부, 2006). 행정중심 복합도시는 금강 유역내 14개 소유역 중 연기군, 공주시 및 청원군이 포함되어 있는 3011 소유역에 해당된다. 신도시 건설에 따른 유입인구 발생으로 인하여 생활용수를 포함한 각종 용수수요도 증가하는 것이 필연적이다. 따라서 금강수계의 KModSim 네트워크를 이용하여 인구가 20만명에서 50만명으로 증가하는 시나리오별로 3011 소유역내 행정중심복합도시 건설 전 후에 대한 용수수급의 변화를 비교 분석하였다. KModSim을 사용하여 2006년 기준수요에 대한 물수지 분석을 수행하였다. 물수지 분석 계산시간 간격은 반순단위로 수행하였으며, '66년 10월$\sim$'03년 9월까지의 기간에 대해 수행하였다. 생활 및 공업용수의 회귀수량은 수요량의 65%가 하류로 회귀되는 것으로 하였으며, 농업용수는 수요량의 65%(순물소모량)을 사용하고 회귀는 없는 것으로 하였다. 각 수요처로부터 하천으로 회귀되는 양은 직 하류에 위치한 소유역으로 유출된다. 각 소유역에서 용수의 취수가용량은 85%로 하였고 나머지는 하류 지점으로 회귀되는 것으로 하였다. 댐 간연계운영 방법은 KModSim에서 제공하는 Reservoir Balancing을 통해 댐 간에 동일비율로 수요를 공급하도록 하였다. 수요처의 우선순위는 상류에서 하류로 증가하도록 하고, 하천유지용수, 생활용수, 공업용수, 농업용수 순으로 부여하였다. 소유역구분은 국가 표준지도인 수자원단위지도를 이용하여 금강권역을 21개 중권역으로 구분하여 물 수급 평가 및 전망을 수행하였다.

  • PDF

A Study on Evaluation Methods for the Fire-retardant Performance of Hanok Components (건축 마감재의 화재안전기준 비교분석을 통한 한옥 부재의 난연성능 평가기준 연구)

  • Kwark, Ji-Hyun;Choi, Jung-Min;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.1-7
    • /
    • 2011
  • In this study, standards and test methods for building materials of domestic and foreign countries were compared and analyzed to propose evaluation methods for the fire-retardant performance of HANOK components (Traditional house). IBC and NFPA codes recently have been adopted in the US, and the properties such as critical heat flux, fire spread index and smoke density are being used as an evaluation reference. In Europe, the unified Euroclass has been adopted and the surface flammability, prototype fire test or cone calorimeter test are conducted for the performance test. Japan has the similar system as Korea where the class is classified into 3 grades. We tried to study a quantitative evaluation method of fire retardant performance for the HANOK components based on the analysis results of the several countries' standards and test methods for building materials.

Experimental and Numerical Studies on Heat/Smoke Behavior due to a Fire on Underground Subway Platform (I) - Experimental Approach - (지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구(I) - 실험적 접근 -)

  • Park, Won-Hee;Kim, Dong-Hyeon;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.9-14
    • /
    • 2006
  • In this study boundary velocity which is one of the important boundary conditions for numerical simulation for subway station on fire are experimentally obtained. The tests were conducted according to its operating mode of the ventilation systems in the platform: smoke extraction ventilation mode in occurrence of fire and normal ventilation mode for air conditioning. Velocities are measured at various points on the platform. To examine smoke extraction and air supply capacity in the platform level, air velocities were checked on opening vents. Numerical analysis under normal ventilation mode without fire is conducted by using measured boundary conditions, and the numerical results are compared with the measured velocities on the platform.

Development and Evaluation of Portable Multiple Gas Meter (휴대용 다중 가스측정 장비 개발 및 평가)

  • Jang, Hee-Joong;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.483-490
    • /
    • 2019
  • Assessing the effect of forest fires and measuring the gas concentration around a fire has received little attention. Therefore, the concentrations of various gases in areas surrounding a fire need to be measured by the development of a suitable device. Unlike conventional portable devices, the AQS (Air Quality System) proposed in this paper is a portable instrument that measures five types of gases simultaneously, including CO, CO2, NOx, VOCs, and NH3, and has high durability through sensor protection algorithms. A PC-based program with an AQS connection was developed to monitor the real-time changes in the gas concentration. The reliability of the developed device was proven through a comparison of the results with other commercial gas analyzers. Measurements of the concentration due to indoor and outdoor fires were performed around a fire area to review the applicability and the predicted results were obtained.

An Experimental Study on the Determination of Backlayering Distance in Tunnel Fires (터널 화재시 역기류의 위치 결정에 관한 실험적 연구)

  • 이성룡;유홍선
    • Tunnel and Underground Space
    • /
    • v.14 no.4
    • /
    • pp.269-274
    • /
    • 2004
  • In this study reduced-scale experiments were conducted to determine the backlayering distance in tunnel fires. The 1/20 scale experiments were carried out under the Froude scaling using ethanol square pool fire ranging from 8 to 1km in each side with total heat release rate from 2.47 to 12.30 ㎾. It has been found that ventilation velocity increases with aspect ratio(tunnel height/tunnel width). At L$\_$B/$\^$*/ <5 the ventilation velocity increases proportional to the backlayering distance from 0.25 power of the heat release rate. However at L$\_$B/$\^$*/ $\geq$5 the ventilation velocity varies as the 0.3 power of the heat release rate.

Evaluation of the Burning Properties of Various Carpet Samples by using the Cone Calorimeter and Gas Toxicity Test (콘칼로리미터와 가스유해성 시험법을 이용한 카페트류의 연소특성 평가)

  • Lee, Bong-Woo;Kwon, Seong-Pil;Lee, Jang-Won;Lee, Byoung-Ho;Kim, Hee-Soo;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • In this study, the burning behaviours of five different kinds of carpet samples covered with nylon, PP (polypropylene), PTT (poly(trimethylene terephthalate)), wool fabric and NW (nylon and wool) were evaluated by using the cone calorimeter having a radiant flux of 50kW/$m^2$. And the combustion gas toxicity was evaluated according to KS F 2271 test method. As a result of the cone calorimeter test (KS F ISO 5660-1), nylon carpet samples were ignited most easily. In ignition ability or initial flammability, NW carpet samples showed the highest value. In heat release rate (HRR), fire intensity, PP carpet samples were larger than any other samples. Nylon carpet samples were the highest smoke production rate, while N/W carpet samples the lowest. The following were in mass loss rates: NW > wool > nylon > PP > PTT. CO (carbon monoxide) was one of the most toxic gases released from the combustion. PTT carpet samples gave rise to the highest CO concentration, while NW carpet samples the lowest. In addition, PP carpet samples caused the highest $CO_2$ (carbon dioxide) concentration, while NW carpet samples the lowest. Toxicity of the gas produced from carpet samples was determined by the mouse stop motion, and it resulted in the fact that the combustion gas of PTT carpet samples was more toxic than that of any other samples.

Preparation of Hydrazinium 5-aminotetrazolate(HAT) with High Nitrogen Content and Energetic Material (고질소 에너지 물질 Hydrazinium 5-aminotetrazolate (HAT)의 제조)

  • Lee, Woonghee;Kim, Seung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.53-59
    • /
    • 2019
  • Solid fuel reacts with an oxidizer during combustion of a propellant to increase performance. Representative solid fuels are aluminum, cyclotrimethylenetrinitramine (RDX) and octahydro-1, 3,5,7-tetra nitro-1,3,5,7-tetrazocin (HMX). During combustion, these compounds generate white smoke by reacting with moisture and produce materials that are harmful to the environment, such as carbon monoxide, carbon dioxide, and methane gas. This study prepared a high-nitrogen-containing energetic material, hydrazinium 5-aminotetrazolate (HAT), which could be applied as a solid fuel. The compound was characterized by nuclear magnetic resonance (NMR) spectroscopy, and a thermal analysis was measured by differential scanning calorimetry (DSC). Also, the specific impulses and volumes of detonation gases were calculated using the EXPLO5 program.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

A Numerical Study for Fire Safety Evaluation of the Multi-story Residential Buildings -The Effects of the Openings of Stairwell on Fire Characteristics- (다세대주택의 화재안전평가에 대한 수치해석 연구 -계단실 개구부의 개폐가 화재특성에 미치는 영향-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.15-23
    • /
    • 2007
  • In the events of a fire in the residential building, highly flammable polyurethane foam sofa produce toxic smokes. In this type of fire, the residents of the building can be gotten into the difficulties of evacuating from the fire places or may be to death due to a lot of hot toxic gases. In this study, CFD simulations were carried out to study the effects of the openings of stairwell on the fire characteristics of fire room and stairwell. Also, analysis of fire hazard based on the tenability limits of fire and FED(fractional effective dose) was performed to evaluate the life safety of the residents of the building. In the fire room, maximum temperature was about $290^{\circ}C$, maximum CO concentration was about 4,740 ppm, and the time to incapacitation of residents in fire room was about t=144 s. In the stairwell, temperature and CO concentration in the condition of openings to be open were even lower than those in it to be closed. Time to the tenability limit with respect to smoke visibility in the stairwell with openings, which was open, was shorter than that of it without openings to be open. It has been shown from this study that opening the stairwell openings is able to decrease the fire hazards to the life safety in the multi-story residential building fire.