• Title/Summary/Keyword: 연기발생량

Search Result 125, Processing Time 0.025 seconds

A Concurrent Transmission for Improving Throughput in Wireless LANs (무선랜 환경에서 처리량 향상을 위한 동시 전송)

  • Cho, Yong Kwan;Rhee, Seung Hyong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.12
    • /
    • pp.984-986
    • /
    • 2013
  • DCF(Distributed Coordination Function) defined in IEEE 802.11 provides two different modes, namely, a 2-way handshake and a 4-way handshake according to the transmission procedure. If secondary transmission would not cause a collision with primary transmission, there is no need to postpone transmission unnecessarily. We study a feasible condition which can transmit data concurrently and propose a concurrent transmission scheme.

Measurement of Environmental Tobacco Smoke in Office Environments (사무실 환경에서의 간접흡연 노출량 측정)

  • 백성옥;박상곤;황승만;정진욱;김미현;박지혜
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.43-44
    • /
    • 2000
  • 흡연 당사자의 직접흡연이 이와 관련한 발병률과 사망률의 주요 원인이 되어 왔다는 것은 여러 연구조사자료에 보고되어 왔다. 그러나 최근 들어 담배연기에 대한 비흡연자의 비자의적인 노출 즉, 환경담배연기(Environmental Tobacco Smoke, 이하 ETS)로 인한 보건학적 위해성에 대한 논란이 제기되면서 간접흡연은 새로운 사회문제로 대두되고 있다(Surgeon General, 1986). 1986년에 미국 National Research Council은 미국 내에서 연간 3000명에 달하는 폐암의 발생이 ETS에 대한 노출에서 기인한다고 발표한 바 있으며(NRC, 1986), 이를 근거로 1990년대 초에 미국 EPA와 NIOSH에서는 세계최초로 ETS를 인체발암성물질로 규정한 바 있다(NIOSH, 1991; USEPA, 1992). (중략)

  • PDF

Reduced-Scale Tests of A Intelligent Tunnel Smoke-Control System (지능형 터널 배연시스템 축소모형 실험)

  • Son, Yun-Suk;Park, Won-Hee;Kim, Chi-Hun;Jung, Woo-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.378-383
    • /
    • 2011
  • 지능형 터널 배연시스템은 터널상부의 온도를 감지하는 온도감지부에서 들어오는 신호를 해독하여 화재위치 및 화재크기를 선정하고 제연설비의 운전방향 및 배연량을 조절함으로써 연기를 효율적으로 제어할 수 있는 시스템이다. 지능형 터널 배연시스템의 성능을 검증하기 위하여 실물터널의 크기를 1/60로 축소한 모델에서 두가지의 화원위치에 따라 실험을 수행하였다. 화재 발생 후 초기에는 온도가 상승하다가 제연팬이 작동하면 온도가 급격히 낮아진 후 일정하게 유지되면서 서서히 증가한다. 터널화재시 승객의 피난 장애를 주는 연기의 제어를 통해 터널의 안전성을 향상시킬 수 있는 것을 확인하였다.

  • PDF

A Study on the Fire Risk of Car Interior Materials (자동차 내장재의 화재위험성에 관한 연구)

  • Lee, Hae-Pyeong;Kim, Young-Tak
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.82-88
    • /
    • 2010
  • In this study, we have performed several tests for composite plastic materials to be applied on interior materials of a vehicle to identify their combustion characteristics using cone calorimeter, smoke density chamber and toxicity index chamber. We have prepared a total of 12 samples for 4 major parts of a vehicle wherein each major part has 3 different materials. The results of cone calorimeter test showed ignition time of PVC sheet and PVC leather were 2s. The 8 samples showed under less than 10s of ignition time. The sample comprising Nylon and PE had the biggest maximum heat release rate of 635 $kW/m^2$. The sample comprising Rubber showed the smallest maximum heat release rate but with the biggest total heat release. The results of smoke density chamber test showed the sample that is made up with Rubber had the biggest specific optical smoke density. The sample comprising PVC leather and PUR showed the biggest VOF4 which enables the initial smoke production. The results of toxicity index test showed that all samples contained carbon dioxide content exceeding its lethal concentration. The sample comprising PVC showed high content of hydrogen chloride and hydrogen bromide. The PVC sheet showed the biggest toxicity index calculated by using lethal concentration and test results. Toxicity index of all sample wes over 1.

A Study on the Investigation and Combustibles Test of Combustion in Welfare Facilities of Handicapped (장애인 복지시설의 주요가연물 조사 및 연소실험에 관한 연구)

  • Son, In-Tea;Seo, Dong-Goo;Hong, Hae-Ri;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.314-317
    • /
    • 2011
  • 최근 국내 장애인 복합시설의 증가와 함께 많은 사고 사례가 발생하고 있다. 하지만 장애인 시설 화재시 재실자가 장애인으로 비장애인 보다 피난 효율이 저하되어 수 많은 인재가 발생하고 있다. 따라서 장애인시설 피난 방화와 관련하여 강화된 규정이 필요하고 많은 연구가 이루어져야 할 것이다. 이에 따라 국내 장애인복합시설을 대상으로 가연물 조사와 Cone Calorimeter 실험을 통해 화재하중과 가연물 연소성상 등을 연구 분석한 결과 장애인 시설의 화재하중이 공동주택보다 높다는 것을 확인하였다. Cone Calorimeter 실험을 통해서 6개 시료 중 4개의 시료가 기준치 이상의 발열량을 보였고, 방염블라인드의 경우 Co, $CO_2$ 유해연기의 검출량이 기준치 이상으로 그 위험성을 확인 할 수 있었다.

  • PDF

Study on Runoff Property in Non-point Source Reduction Facility (비점오염 저감시설의 유출특성에 관한 연구)

  • Kwak, Hyun-Gu;Yeon, Ki-Suk;Kim, Jong-Sub;Ryu, Byong-Ro
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1365-1369
    • /
    • 2009
  • 최근 비점오염원 부하의 심각성이 알려지면서 4대강 유역을 중심으로 비점오염원의 조사 및 관리를 위한 대책 마련과 제도관 관리방안이 모색되고 있다. 이중 낙동강 유역은 총 면적 약 $23,384km^2$로 국토 전체 면적의 약 1/4을 차지하고 있지만 연평균 강수량은 1,186mm로 4대강 수계 중 가장 적어 갈수기에 자연 하천유량의 부족 및 유역외 지역에서의 공업용수 사용으로 낙동강하류의 유량감소를 초래하여 수질악화와 생태계 파괴가 심화되고 있는 상황에서 비점오염물질로 인해 그 피해가 가중되고 있다. 이에 본 연구에서는 도시지역, 도로, 농경지, 토양침식물, 축사유출물, 대기강하물 등 광범위한 지역에서 강우 유출수와 함께 배출되는 비점오염물질을 처리하기 위하여 낙동강 수계내 대구 달성 소유역에 시범적으로 설치 운영중인 저감시설(CDS)의 수질 및 유량 모니터링 자료를 이용하여 대상유역의 강우-유출 특성 및 오염부하량 특성을 살펴보고, 전체유역의 유출발생량과 비점오염원 저감시설의 유입량 대비 처리 효율을 분석함으로써 오염부하량 발생 및 저감효율에 관한 연구를 수행하였다. 이를 위해 강우-유출 및 수질 모니터링 자료를 이용하여 모형(XP-SWMM)의 검보정을 실시하여 모델링 매개변수를 조정하였고, 강우-유출해석을 실시하여 대상유역의 년간 유출특성 및 비점 오염원 저감시설의 년간 오염부하량 저감율을 분석하였다.

  • PDF

A Study on Mapping Forest Fire Risk Using Combustion Characteristic of Forest Fuels : Focusing on Samcheok in Gangwon-do (산불연료의 연소특성을 활용한 산불위험지도 작성에 관한 연구 : 강원도 삼척 시를 중심으로)

  • Lee, Haepyeong;Park, Youngju
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.296-304
    • /
    • 2017
  • In order to predict about forest fire behavior we constructed a database for combustion characteristic of forest fuels in Samcheok, Gangwon-do and prepared fire risk map and fire risk rating using GIS method in this study. For the mapping autoignition temperature, ignition time, flame duration time, total heat release and total smoke release are selected as the standardized parameters and the overall risk rating was made up of the ignition risk parameters(autoignition temperature, ignition time) and the spread risk parameters(flame duration time, total heat release, total smoke release). Forest fire risk was classified into 5 grades and lower grade of fire risk rating mean to correspond to more dangerous forest fire. As a result, the overall risk rating of Samcheok was classified into three grades from 1 to 3 and Nogok-myeon and Miro-myeon were turned out the most dangerous areas for forest fire. Because of the colony of pine and oak trees and the higher fire loads, the flame propagation will be carried out quickly in these areas.

Experimental Study on the Designed Ventilation System Performance at Rescue Station in Tunnel Fire (터널 내 화재발생시 구난역 내의 설계된 환기 시스템 성능에 대한 실험적 연구)

  • Kim, Dong-Woon;Lee, Seong-Hyeok;Ryou, Hong-Sun;Yoon, Sung-Wook
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • In this study, the l/35 reduced-scale model experiment were conducted to investigate designed ventilation system performance at rescue station in tunnel fire. A model tunnel with 2 mm thick of steel, 10 m long, 0.19 m high and 0.26m was made by using Froude number scaling law. The cross-passages installing escape door at the center. were connected between accident tunnel and rescue tunnel. The n-heptane pool fire, $4cm\times4cm$, with heat release rate 698.97W were used as fire source. The fire source was located in the center and portal of accident tunnel as Worst case.. An operating ventilation system extracted smoke amount of 0.015 cms. The smoke temperature and carbon monoxide. concentration in cross-passage were measured to verify designed ventilation system. The results showed that, in center fire case without ventilation in accident tunnel, smoke did not propagated to rescue station. In portal tire case, smoke spreaded to rescue station without ventilation. But smoke did not propagated to rescue station with designed ventilation.

The Experimental Study on the Leakage of Automatic Pressure Differential · Overpressure Control Dampers (자동차압 · 과압조절형댐퍼의 누설량 실험 연구)

  • Shin, Pyung-Shik;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.71-75
    • /
    • 2015
  • Recently, Since buildings are bigger and higher, the damage of human life can be increased by fire flame and smoke in fire. Smoke control system is necessary to decrease this damage. Therefore, Air supply pressurization smoke control system is applied to vestibule of escape stairway. NFSC requires pressure differential of 40 Pa~60 Pa, but pressure differential is over 60 Pa in the field. It is known that the cause of this over pressure differential is much leakage of damper. Over pressure differential can bad effect to escaper by pressurizing the door. Analyze the real leakage of damper by testing for identifying this problems. The result of testing, leakage is $0.090m^3/s{\sim}0.154m^3/s$. It is necessary to limit the leakage of dampers for safe of escapers.

The Differences of the Smoking Habit Between Emphysema and Chronic Bronchitis (폐기종과 만성기관지염의 흡연습관 차이)

  • Mun, Yeung-Chul;Yu, Sung-Keun;Park, Hye-Jung;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Jung-Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.6
    • /
    • pp.693-703
    • /
    • 2001
  • Background : Smoking is the most important and consistent determinant of the development and progression of COPD(Ed Note : Define COPD). The fact that cigarette smokers develop a different type of COPD, chronic bronchitis and emphysema, with different clinical and pathological aspects, suggests that the development of COPD has a relationship with other smoking-associated factors beyond just a simple smoking history. The aim of this was to analyze the smoking habits and history of patients with COPD and to evaluate the development of different types of COPD according to patient's smoking habits. Method : To evaluate the differences in the smoking patterns of patients with chronic bronchitis and emphysema, a pulmonary function test was conducted, and the smoking history and patterns was obtained through a smoking history questionnaire by a direct personal interview from 333 male cigarette smokers diagnosed with COPD, in the Yeungnam university medical center(190 patients diagnosed with chronic bronchitis, 143 patients diagnosed with emphysema). Result : The patients with emphysema smoked earlier and had a higher smoking history(ie, more packyears, more total amounts of smoked cigarette, and more deep inhalation and longer duration of plain cigarette exposure) than those with chronic bronchitis. The depth of inhalation was also significantly higher in the emphysema patients after taking into account age, cumulative cigarette consumption and the type of cigarette smoked. Conclusion : Emphysema was more associated with the increasing degree of inhalation as assessed by the depth of inhalation. A high alveolar smoke exposure may be a significant risk factor for the development of emphysema.

  • PDF