• Title/Summary/Keyword: 역류 현상

Search Result 84, Processing Time 0.023 seconds

Counter-Current Flow Limitation Model Based on the Hyperbolic Two-fluid Equations and Interface Shape Function (쌍곡선형 이상유동 방정식과 경계면 모양함수를 이용한 유체기계의 역류유동제한점 예측방법 개발)

  • 정지환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • There are lots of industrial machines of which functions are achieved by operation of multi-phase fluids. Some of them take advantage of the characteristics of counter-current two-phase flow The maximum flow rates of gas and liquid phases which flow in opposite-directions (counter-current flow) are limited by a phenomenon known as a Counter-Current Flow Limitation (CCFL or Flooding) The mass and momentum conservation equations for each Phase were established to build a first-order hyperbolic partial derivative equations system. A new CCFL model is developed based on the characteristic equation of the hyperbolic PDE system. The present model has its applicationto the case in which a non-uniform flow is developed around a square or sharp-edged entrance of liquid phase. The model is able to he used to Predict the operating-limit of components in which mass and heat transfer are taking place between liquid and gas phases.

  • PDF

Artifacts due to Retrograde Flow in the Artery and Their Elimination in 2D TOF MR Angiography (2D TOF 자기공명 혈관조영술에서 동맥혈류의 역류로 인한 영상훼손과 이의 제거)

  • Jung, K.J.;Lee, J.K.;Kim, S.K.;Park, S.H.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.38-42
    • /
    • 2001
  • Dark band artifacts are often observed in angiograms of arteries obtained by 2D time-of-flight (TOF) angiography with saturation of veins by presaturation RF pulses. At some arteries the arterial blood velocity varies in a triphasic pattern during a cardiac cycle. The arterial blood, that is saturated by presaturation RF pulses in the saturation band, can flow back into the imaging slice during the retrograde flow phase of the triphasic variation. When such saturated retrograde flow occurs during the acquisition of the central part of the K space, a signal void can result in base images and consequently dark band artifacts can appear in angiograms. This phenomenon is experimentally demonstrated by varying the gap between the imaging slice and the saturation band. Furthermore, a new pulse sequence is proposed to eliminate the dark band artifacts by changing the profile of the saturation band front a rectangle to a ramp.

  • PDF

A Study for Regulating Flow Fluctuation and Preventing Backflow of Peristaltic Pump (연동펌프의 유량맥동 조절과 역류현상을 방지하는 장치에 대한 연구)

  • Jeong, Yoo-seok;Lee, Cheol-Soo;Lee, Tae-Kyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.5
    • /
    • pp.28-34
    • /
    • 2016
  • Though a peristaltic pump is a crucial element in miniaturized drug delivery systems, it has some intrinsic disadvantages such as backflow and flow fluctuation. To overcome these limitation, we have developed valve-less peristaltic pump system including orifice and stagnation chamber. we measured flow rate to investigate the performance of rotary peristaltic pump with three rollers and an elastomeric tube pumping a viscous fluid. The flow fluctuations and the backflow happen as a result from the disengagement of the contact interaction between the rollers and the tubes. Stagnation chamber installed in front of orifice plate was composed of rubber tube and gas chamber. By changing orifice hole diameter with stagnation chamber flow rate and pressure in the tube was regulated. The obtained maximum reduction ratio of flow fluctuation is 96.79%.

Theoretical Backgrounds of Reverse Osmosis (막분리의 기본 원리 -역삼투(Reverse Osmosis)-)

  • 민병렬
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.159-174
    • /
    • 1997
  • 삼투현상이란 반투막을 사이에 두소 저농도의 용매가 고농도의 용액으로 이동하는 현상으로 막양측 용매의 화학포텐셜이 같아지게 되면 용매의 이동은 정지되고 수두차 만큼의 삼투압차가 발생한다. 이 때 고농도 용액측에 삼투압차 이상의 압력을 가하게 되면 삼투현상과는 반대로 고농도 용액측의 용매가 저농도의 용액측으로 역류하는데 이를 역삼투현상이라 한다. 역삼투현상을 이용하여 물질을 분리하는 역삼투 공정은 막의 물리화학적 특성, 분리대상물질의 물리화학적 특성, 그리고 압력차를 추진력으로 하는 세가지 요소의 조합에 의해 행하여 진다. 역삼투는 분자크기에 따른 분리조작이 아니므로 정밀여과나 한외여과에서와 같은 유기물질의 침착현상이 적으며 결과적으로 막의 수명도 길어진다. 역삼투막은 용존염을 분리제거할 뿐만 아니라 분자량이 적은 유기물 및 Aromatic hydrocarbon 등의 분리조작에도 그 이용가능성이 고조되고 있다.

  • PDF

Numerical Study of Bubble Growth and Reversible Flow in Parallel Microchannels (병렬 미세관에서의 기포성장 및 역류현상에 관한 수치적 연구)

  • Lee, Woo-Rim;Son, Gi-Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.2
    • /
    • pp.125-132
    • /
    • 2008
  • The bubble dynamics and heat transfer associated with nucleate boiling in parallel microchannels is studied numerically by solving the equations governing conservation of mass, momentum and energy in the liquid and vapor phases. The liquid-vapor interface is tracked by a level set method which is modified to include the effects of phase change at the interface and contact angle at the wall. Also, the reversible flow observed during flow boiling in parallel microchannels has been investigated. Based on the numerical results, the effects of contact angle, wall superheat and the number of channels on the bubble growth and reversible flow are quantified.

Analysis of the Inland Flood Prevention by Drainage Pumping Station (배수펌프장 설치에 따른 내수침수저감 효과분석)

  • Lee, Jeongwoo;Park, Inchan;Kim, Munmo;Cho, Woncheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.799-803
    • /
    • 2004
  • 본 연구에서는 파주시 일부지역으로서 시가지 밀집지역이고 외수의 영향이 심한 문산 배수펌프장 유역과 2000년에 신설된 선유3 배수펌프장 유역을 선정하여 2003년도 주요 호우사상에 대한 내배수시스템의 유출특성을 분석하였으며, 배수펌프장 설치 유무에 따라 우수유출량을 배수관망을 통해 하류 하천으로 배수시킬 수 있는지를 분석하여 배수펌프장이 내수침수저감에 미치는 영향을 평가하였다. 유출모의는 관거내 수면을 계산하고 배수, 역류, 압력류, 월류까지도 모의할 수 있는 SWMM의 EXTRAM 블록 이용하였다. 유출모의를 수행한 결과, 배수펌프장이 설치된 현재 상태에서는 우수유출량을 원활히 배수시킬 수 있었으나, 배수펌프장이 설치되어 있지 않다고 가정한 경우에는 비교적 작은 호우사상이더라도 첨두강우 발생후 수시간 경과후에 관거말단부 하천 외수위의 영향으로 배수 및 역류현상이 발생하였으며 일부지역에서는 상당한 유량이 지면으로 월류하여 침수가 발생할 가능성이 매우 큰 것으로 분석되었다. 결론적으로 하천 외수위에 의한 영향을 고려하여 하수관거의 통수능을 평가하고 배수펌프장 설치의 타당성을 평가하여야 한다.

  • PDF

Inundation Analysis by Considering Characteristics of Urban Runoff (도시유출특성을 고려한 침수 분석)

  • Lee, Jung Ho;Jo, Deok Jun;Lee, Eui Hoon;Kim, Joong Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.870-874
    • /
    • 2004
  • 도시지역 배수암거의 설계빈도는 호우 발생시 배수 기능을 원만히 수행하기에 부족한 경우가 많으며, 최근 발생 빈도가 높은 국지적 집중호우에 내하여 배수기능 수행이 취약한 실정이다. 특히, 저지대 역류 현상에 따른 침수피해는 도시 설계 및 관거 개량사업에 있어서 반드시 해결해야할 문제점으로 제시된다. 본 연구에서는 강우분석을 통한 도시유출특성을 고려하여 현행 배수암거의 설계빈도에 대한 통수능력을 검토하였으며, 방류하천의 계획홍수위 영향을 고려하여 암거내 역류 및 저지대 침수량을 분석하므로써 배수암거 설계빈도 채택의 적정성 및 저류시설 설치규모 검토를 위한 기준을 제시하었다.

  • PDF

Reverse Flow Phenomena in a Circular Duct with an Obstruction at the Entry (원형 덕트 입구의 장애물이 있는 경우의 역류 유동 현상)

  • Zhang, Y.Z.;Sohn, C.H.;Gowda, B.H.L.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.36-41
    • /
    • 2006
  • Reverse flow (i.e. flow in the direction opposite to the free stream) inside a channel occurs when an obstruction is placed at certain positions near the near to the channel, placed in another wider channel. In this paper the reverse flow in a duct (diameter D) with an obstruction at the front (which is a disc), is investigated using PIV. The gap g between the obstruction and the entry to the duct is systematically varied and it is found that maximum reverse flow occurs at a g/D value of 0.5. The flow is stagnant around g/D of 1.25 and forward flow occurs for g/D values of 1.5 and above.

  • PDF

Study of Design Optimization of Reverse-Annular Type Combustor for Small Gas Turbine Engine (선회형 보염구조의 환형 역류형 연소기 최적화)

  • Park, Hee-Ho;Kim, Ki-Tae;Sung, Ok-Seok;Lim, Byeung-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.401-405
    • /
    • 2011
  • Although the APU combustors were developed successfully, it could face many unexpected hardships in a engine or a system operated under the severe environment. This study is to be verified and settled by experimently and analytically of the problems and issues occurred in a variety of engine and system operation tests.

  • PDF

Syringe Reuse Issues in Automated Contrast Injection System in Dynamic Magnetic Resonance Imaging (조영제 자동주입기를 활용한 자기공명영상 동적검사 시 실린지 재사용의 문제)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.445-450
    • /
    • 2019
  • This study proves that syringe reuse of automated injection system entails a risk of contrast media reflux and saline solution contamination which are pumped by a piston into the patients' venous cannula in the dynamic MR images, we will be aware of the serious problem. To quantify the contrast media contamination effect on the saline solution, identical volume of the saline solution was collected before and after the contrast injection to the patients' venous cannula following T1 weighted image scanning to verify whether signal intensities differences are observed. The signal intensity of saline solution after the contrast injection was significantly higher than that of saline before injection by 523.43%. This result is due to the backflow that contaminates the saline solution on the opposite side when the contrast agent is injected. In conclusion, the syringe used to inject contrast medium. causes cross-contamination due to contrast reflux. Therefore, even if the same patient's examination is used for quantitative analysis, the error should be avoided by changing the acquisition sequence or replacing the syringe.