• 제목/요약/키워드: 여재의 선정

Search Result 16, Processing Time 0.036 seconds

Filter Media Specifications for Low Impact Development: A Review of Current Guidelines and Applications (LID 시설 여재에 관한 기술지침 및 적용에 관한 고찰)

  • Guerra, Heidi B.;Kim, Lee-Hyung;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.321-333
    • /
    • 2019
  • A primary aspect of low impact development (LID) design that affects performance efficiency, maintenance frequency, and lifespan of the facility is the type of filter media as well as the arrangement or media profile. Several LID guidelines providing media specifications are currently available and numerous studies have been published presenting the effectiveness of these systems. While some results are similar and consistent, some of them still varies and only a few focuses on the effect of filter media type and arrangement on system performance. This creates a certain level of uncertainty when it comes to filter media selection and design. In this review, a synthesis of filter media specifications from several LID design guidelines are presented and relevant results from different laboratory and field studies are highlighted. The LID systems are first classified as infiltration or non-infiltration structures, and vegetated or non-vegetated structures. Typical profiles of the media according to classification are shown including the different layers, materials, and depth. In addition, results from previous studies regarding the effect of filter media characteristics on hydraulic and hydrologic functions as well as pollutant removal are compared. Other considerations such as organic media leaching, clogging, media washing, and handling during construction were also briefly discussed. This review aims to provide a general guideline that can contribute to proper media selection and design for structural LIDs. In addition, it also identifies opportunities for future research.

Selection of Optimum Pebbles Size in Sewage Treatment Plant by Natural Purification Method (자연정화공법에 의한 하수처리장에서 최적 여재 선정)

  • Seo, Dong-Cheol;Cho, Ju-Sik;Park, Hyun-Geoun;Kim, Hyoung-Kab;Heo, Jong-Soo;Lee, Hong-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.1
    • /
    • pp.26-35
    • /
    • 2003
  • An investigation was carried out to evaluate the effects of pebble size on the small-scale sewage treatment apparatus by natural purification method that consisted of aerobic and anaerobic plot. pH and EC in both plots varied minimally regardless of pebble size. DO in aerobic plot increased as the pebble size decreased. That in the anaerobic plot was slightly less in comparison with that of the aerobic plot but varied minimally, $2.4{\sim}5.1\;mg/L$ regardless of pebble size. Under all experimental conditions, removals of BOD, COD and turbidity in anaerobic plot were more than 98, 91 and 98, 98% respectively. Removals of T-N and T-P increased as pebble size decreased. Under all experimental conditions, removals of T-N and T-P in anaerobic plot were about $45{\sim}59$ and $480{\sim}96%$, respectively. Judging from the above results, it should be considered that the optimum pebble size and pebble permeability in both plot was $2{\sim}4$ and $0.1{\sim}4\;mm$, respectively.

Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties (여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가)

  • Kim, Tae-Gyun;Cho, Kang-Woo;Song, Kyung-Guen;Yoon, Min-Hyuk;Ahn, Kyu-Hong;Hong, Sung-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.483-490
    • /
    • 2009
  • The aims of this study were to evaluate the removal efficiency for various pollutants in urban storm runoff by a filtration device, and to determine design parameters depending on filter media properties. Appropriate selection of filter media will affect the size and life time of the filtration device. Sets of column tests were performed in order to evaluate the removal efficiency by perlite and a synthetic resin. An investigation of surface properties including CEC (cation exchange capacity) and zeta-potential suggested that the perlite had a superior adsorption capability for cationic pollutants. TCODcr and turbidity were analyzed to investigate the removal characteristic of particulate pollutant. In both columns, the particles in the collected storm runoff was almost completely capture with a small EBCT (empty bed contact time) of 2.5 minutes. Complete clogging at the EBCT of 2.5 minutes occurred after 630 minutes in the perlite column and 810 minutes in the resin column. The removal efficiency of TCODcr and turbidity at the EBCT of 2.5 minutes decreased to below 70% due to an wall effect. The removal efficiency for dissolved pollutant (SCODcr) was negligible due to the insufficient contact time for adsorption. The removal of heavy metals (Cu, Zn, Pb) was mostly ascribed to the filtration of particles containing metals, since the relationship between CEC and the removal efficiency was not apparent. The result of this study would be valuable for the application of filtration device to control of urban storm runoff.

Selection of Optimum Filter Media in Small-Scale Livestock Wastewater Treatment Apparatus by Natural Purification Method (자연정화공법을 이용한 소형 축산폐수처리장치의 최적여재 선정)

  • Kim, Ah-Reum;Kim, Hong-Chul;Seo, Dong-Cheol;Park, Jong-Hwan;Kim, Sung-Hun;Lee, Seong-Tae;Jeong, Tae-Uk;Choi, Jeong-Ho;Kim, Hyun-Ook;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.285-292
    • /
    • 2011
  • In order to develop livestock wastewater treatment technology by natural purification method, the optimum filter media in small-scale livestock wastewater treatment apparatus for treating livestock wastewater were studied. Removal rates of pollutants under different filter media were in the other of coarse sand ${\fallingdotseq}$ broken stone > zeolite > calcite for COD, zeolite >> broken stone ${\fallingdotseq}$ coarse sand ${\fallingdotseq}$ calcite for T-N, and calcite > coarse sand ${\fallingdotseq}$ broken stone ${\fallingdotseq}$ zeolite for T-P. Based on the above results, the optimum filter media was coarse sand in small-scale livestock wastewater treatment apparatus. To meet acceptable effluent quality standard for livestock wastewater and to improve T-N and T-P removal efficiencies, removal efficiencies of pollutants in small-scale livestock wastewater treatment apparatus with mixed filter media were studied. The removal rates of COD, SS, T-N and T-P in effluent were 84, 94, 65 and 98% in small-scale livestock wastewater treatment apparatus with mixed filter media, respectively. For increasing the T-N and T-P removals in small-scale livestock wastewater treatment apparatus, the mixed filter media are recommended.

Screening of the Optimum Filter Media in the Constructed Wetland Systems through Phosphorus Adsorption Capacities (인의 흡착능 평가를 통한 인공습지 하수처리 시스템의 여재 선발)

  • Lee, Hong-Jae;Seo, Dong-Cheol;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.148-152
    • /
    • 2003
  • The phosphorus(P) adsorption capacities of various filter media were investigated in relation to the size and types of fitter media to screen the optimum condition. The objective of this study was to evaluate the constructed wetland longevity by improving P adsorption capacity. The maximum P adsorption capacities of filter media A($4{\sim}10\;mm$), B($2{\sim}4\;mm$) and C($0.1{\sim}2\;mm$) were 8, 10 and 22 mg/kg, respectively, showing those increased as the filter media size decreased. Among the experimental media, the optimum filter media size was $0.1{\sim}2\;mm$. When the filter Medium was supplemented with organic materials which were piled up and decayed in the constructed wetland, the P adsorption capacity was significantly enhanced Under the conditions of optimum fitter media size, the respective Maximum P adsorption capacities of filter media C when supplemented with Ca, Mg, Al and Fe were higher than that of filter media C. However the addition of Ca, Mg, Al and Fe to constructed wetland were not recommended because of the possibility of their secondary pollution. The maximum P adsorption capacity of filter media C was 22 mg/kg, but this was increased to 36 mg/kg when filter media C was supplemented with 2% oyster shell.

Cost-effective assessment of filter media for treating stormwater runoff in LID facilities (비용 효율적 강우유출수 처리를 위한 LID시설의 여재 평가)

  • Lee, Soyoung;Choi, Jiyeon;Hong, Jungsun;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.194-200
    • /
    • 2016
  • The impervious surface rate increased by urbanization causes various problems on the environment such as water cycle distortion, heat island effect, and non-point pollutant discharges. The Low Impact Development (LID) techniques are significantly considered as an important tool for stormwater management in urban areas and development projects. The main mechanisms of LID technologies are hydrological and environmental pollution reduction among soils, media, microorganisms, and plants. Especially, the media provides important functions on permeability and retention rate of stormwater runoff in LID facilities. Therefore, this research was performed to assess the pollutant removal efficiency for different types of media such as zeolite, wood chip, bottom ash, and bio-ceramic. All media show high pollutant removal efficiency of more than 60% for particulate materials and heavy metals. Double layered media is more effective in reducing heavy metals by providing diverse sizes of micro-pores and macro-pores compared to the single layered media. The results recommend the use of different sizes of media application is more cost-effective in LID than a single size of media. Furthermore, soluble proportion of total heavy metal in the stormwater is an important component in proper media selection and arrangement.

Evaluation of the pre treatment tank filter media layer in LID technologies (LID 기법 전처리 시설 내 여재층 특성 평가)

  • Choi, Hye Seon;Jeon, Min Su;Geronimo, Franz Kevin;Reyes, Nash Jett;Kim, Lee Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.367-367
    • /
    • 2022
  • 토지이용의 고도화에 따라 비점오염원 부하는 증가하는 추세이며 기후변화에 따른 강우강도 증가 등으로 지표면에 축적된 고농도의 비점오염물질이 하천으로 유출, 수질오염을 가중시키고 있어 비점오염원 관리가 필요하다. LID 기법은 자연적 기작(mechanisms)과 공정(process)을 이용하여 생태계의 물질순환(물순환 포함)과 에너지 흐름이 원활하도록 조성하는 기법으로, 불투수층면에서 발생되는 강우유출수를 관리 가능하다. LID 시설에는 전처리 시설을 두어 초기 고농도의 입자상 물질을 저감시키고, 강우유출수 저류공간을 통한 유출저감, 첨두유량 등을 저감시킨다. 이러한 전처리 시설에는 유기물질 및 영양소의 생물학적 제거를 위한 미생물 서식공간의 제공 등의 역할을 수행하기 위하여 다양한 여재를 적용하고 있다. 본 연구는 비점오염물질 유입이 LID 기법 전처리 시설 내 여재층의 물리·화학적 및 생물학적 환경을 평가하였다. 3개 시설 모두 100%의 불투수층에서 발생되는 강우유출수를 처리하는 LID 시설을 연구대상으로 선정하였으며, 각각의 전처리 시설에는 자갈, 우드칩, 쇄석 등이 적용되어 있다. 퇴적물의 경우 가장 상부에 존재하는 층으로 퇴적물의 오염물질 농도는 2~10.7배 이상 매우 높게 나타났다. 우드칩의 경우 다른 여재에 비해 높은 함수량과 유기물 함량을 보였으며 이는 우드칩의 수분을 보유하는 능력과 거친 표면공극에 오염물질이 부착되기 때문으로 나타났다. 또한, 같은 무기성 여재인 쇄석과 자갈의 경우 여재 크기의 차이를 보임에도 불구하고 미생물의 군집구성과 함수량의 차이를 보이는 것으로 평가되었다. 유기물의 함량이 낮은 강우유출수의 생물학적 처리능력을 향상시키기 위해서는 유기성 여재가 필요하며, 다공성 무기 멀칭재를 적용하고 하부의 토양은 적정 유기물을 배합하여 질산화 및 탈질화 유도가 가능하도록 설계가 필요한 것으로 분석되었다.

  • PDF

Evaluation of the applicability of Cockle shell and walnut shell in a bioretention facility (Bioretention 내 꼬막 및 호두껍질의 적용성 평가)

  • Jeon, Minsu;Geronimo, F.K.F.;Choi, Hyeseon;Kim, Lee-hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.203-203
    • /
    • 2019
  • 도시화로 인한 불투수면의 증가는 물순환 왜곡, 비점오염원 발생 및 수생태계 건상성 훼손 등을 야기시키며, 이를 해결하기 위하여 다양한 LID 기법을 적용하고 있다. 일반적으로 LID 내 적용 되는 여재들은 무기성여재로 중량이 크고 미세공극의 부재로 물리화학적 및 생물학적 저감기능이 제한적이다. 따라서 본 연구에서는 중량성이 낮은 생물폐자원을 선정하여 LID 시설 적용성평가를 수행하고자 한다. 생물폐자원은 발생량, 경량성 및 용이성을 고려하여 꼬막껍질(CS)과 호두껍질(WS)을 선정하였다. 생물폐자원의 산화부식을 고려하여 무기성 여재인 화산석과 혼합하여 Bioretention 시설에 적용하였으며, 여재 혼합비율에 따라 총 3가지의 Case 로 구성하였다. 식생은 구절초와 꽃댕강나무를 식재하였으며, 여재의 물리적 특성 분석을 위하여 적용 전과 후의 SEM(Scanning Electronic Microscope)을 수행하였다. 모니터링은 도로퇴적물 100g과 물 110L를 제조하여 인공강우유출수를 이용하여 수행하였으며, $0.0003{\sim}0.007m^3/sec$의 유속으로 주입하였다. 시설의 유입 및 유출부에서 유량 측정 및 수질 시료를 채취하였으며, 채취된 시료는 수질오염공정 시험법에 준하여 입자상 물질, 유기물, 영양물질 및 중금속 등을 분석하였다. Bioretention 시설의 모니터링 결과를 이용하여 물수지 및 TSS 저감 효율을 산정하였으며. 물수지 분석결과 시설의 저류율은 Case 1(soil) > Case 3(WS+RV) > Case 2(CS+RV) 순으로 나타났다. 시설 내 공극률이 가장 낮았던 Case 1에서 저류율이 약 55%로 가장 높게 것으로 분석되었다. Case 3(WS+RV)은 Case 2(WS+RV)와 시설 내 공극률이 유사함에도 불구하고 저류율이 약 10% 높은 것으로 분석되었다. 오염물질 저감효율 분석 결과, TSS와 TP의 제거효율은 모든 Case에서 약 75% 이상으로 높게 나타났으며, COD의 경우 모래를 적용한 Case 1에 비해 생물폐자원인 꼬막껍질과 호두껍질을 적용한 Case에서 약 1.3배 이상 높게 나타났다. 호두껍질과 꼬막껍질의 SEM 분석 결과 표면에 다공성이 형성되어 있는 것으로 조사되었다. 이는 여과 및 저류기작으로 인한 물순환 효과증대와 다공성과 돌기사이로 인한 입자상의 물질 여과 및 흡착으로 인하여 오염물질의 제거효율이 증대 된 것으로 평가된다. LID시설 내 생물폐자원과 무기성여재를 적절히 배합하여 복합여재로 조성할 경우 침하현상을 방지할 뿐만 아니라 저류 및 침투기능 향상과 미생물의 서식환경을 제공하기에 물순환 회복 및 비점오염물질 저감에 기여할 것으로 평가된다.

  • PDF

레미콘에 의한 사방댐 시공방안

  • 한국레미콘공업협회
    • 레미콘
    • /
    • no.12 s.10
    • /
    • pp.85-87
    • /
    • 1986
  • 다음 자료는 산림청이 11월 12일 개최한 제17회 전국 사방실무세미나에서 경기도치산사업소 여재만씨가 개발, 발표한 내용이다. 「레미콘을 이용한 사방댐시공법」은 깬돌, 자갈, 잡석 등을 이용한 종래의 사방사업 시행때에 인력, 자재 확보난 등의 어려움을 해소하고 공기단축과 사업비를 절감할 수 있는 효과적인 방안으로 평가받고 있다. 새로 개발된 「레미콘을 이용한 사방댐시공법 」은 산림청에서 87년도 최우수 과제로 선정되어 전국적으로 확대 실시할 계획이다.

  • PDF