• Title/Summary/Keyword: 에너지 수요 정보

Search Result 3,075, Processing Time 0.038 seconds

Effect of Trace Metal on Accumulation and Physiological Response of the Polychaete, Perinereis nuntia (미량금속 노출에 따른 갯지렁이(Perinereis nuntia)의 미량금속 축적 및 생리학적인 반응)

  • Won, Eun-Ji;Ra, Kong-Tae;Hong, Seong-Jin;Kim, Kyung-Tae;Lee, Jae-Seong;Shin, Kyung-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.4
    • /
    • pp.288-295
    • /
    • 2010
  • Metal exposure experiments using polychaete (Perinereis nuntia) as a bio-indicator of trace metals contamination were conducted to evaluate the bioaccumulation and the biomarkers responses such as metallothionein-like protein (MTLPs) and glutathione S-transferase (GST) which was simultaneously exposed to Cadmium (Cd) and Copper (Cu). Cu and Cd concentrations in polychaete were enhanced with increasing exposure time and their concentrations of aqueous medium. Initial accumulation of Cd was higher than that of Cu. Our results showed that the bioaccumulation of Cu and Cd were prohibited, especially at higher Cu levels, suggesting the different cellular uptake mechanisms when Cu and Cd are co-exist. Net accumulation rate of Cu was declined with exposure time but it did not show any significant change for Cd. Although the highest MTLPs concentration was observed at 6 hr of exposure time, it did not show any significant change related to exposure times and metals concentrations. An increase of GST activity tended to increase as a function of exposure time and metals concentrations. And GST activities in P. nuntia have similar tendency with bioconcentration factors in high concentration of Cu (treatment group IV) at post 24 h of exposure. Our results provide new information of the bioaccumulation and biomarker responses to understand the effects of co-existing contaminants (Cu and Cd) using polychaete. Further studies are required to elucidate the bioaccumulation and biomarkers responses for various contaminants.

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

A Study on the Role of United Nations Regional Group System for the London Protocol (런던의정서에서 유엔 지역그룹체제의 역할에 관한 연구)

  • Moon, Byung-Ho;Hong, Gi-Hoon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.135-150
    • /
    • 2010
  • At the Intergovernmental Meeting held in 1972, the London Convention was adopted to prevent marine pollution from dumping of wastes and other matter. After that, at the special meeting held at the Headquarters of the International Maritime Organization in 1996, the London Convention was revised to consider advances in technology of treatment and disposal of wastes and to reflect changes in understanding of marine environment and then the London Protocol was concluded. The London Protocol states more concrete management system for ocean dumping than the London Convention and also provides that the Meeting of Contracting Parties shall establish those procedures and mechanisms necessary to assess and promote compliance with the Protocol. With the London Protocol in force since 24 March 2006, the Meeting of Contracting Parties adopted the 'Compliance Procedures and Mechanisms (CPM) pursuant to Article 11 of the 1996 Protocol to the London Convention 1972' and established the Compliance Group in 2007. According to the CPM, members of the Compliance Group shall be nominated by Contracting Parties, based on equitable and balanced geographic representation of the five Regional Groups of the United Nations, and elected by the Meeting of Contracting Parties. In 2009, the Republic of Korea nominated a member of the Compliance Group to be subsequently elected by the Meeting of Contracting Parties with the approval of other states in Asia Group. Through the United Nations Regional Group System based on geographical identity or political affinity, Contracting Parties to the London Protocol are expected to form a voting bloc or to exchange information in meetings on the London Protocol. In this sense, it is noteworthy that the London Protocol introduced marine environmental management system for comprehensive prohibition of ocean dumping with exception of the so-called 'reverse-list' which had been earlier adopted by the 'Convention for the Protection of the Marine Environment of the North-East Atlantic, 1992 (OSPAR)' whose contracting parties belonged to Western European and Other States Group. In recent years, the jurisdiction of London Protocol has been extended to protect and preserve the marine environment from all sources of pollution. This will make the United Nations Regional Group System play more important roles in the activities associated with the London Protocol. For this reason, this article has considered characteristics of the United Nations Regional Group System and has analyzed influences of this Regional Group System in meetings on the London Protocol. This could provide preliminary information for the Republic of Korea to give due consideration to the United Nations Regional Group System on the activities associated with the London Protocol.

Topographic Factors Computation in Island: A Comparison of Different Open Source GIS Programs (오픈소스 GIS 프로그램의 지형인자 계산 비교: 도서지역 경사도와 지형습윤지수 중심으로)

  • Lee, Bora;Lee, Ho-Sang;Lee, Gwang-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.903-916
    • /
    • 2021
  • An area's topography refers to the shape of the earth's surface, described by its elevation, slope, and aspect, among other features. The topographical conditions determine energy flowsthat move water and energy from higher to lower elevations, such as how much solar energy will be received and how much wind or rain will affect it. Another common factor, the topographic wetness index (TWI), is a calculation in digital elevation models of the tendency to accumulate water per slope and unit area, and is one of the most widely referenced hydrologic topographic factors, which helps explain the location of forest vegetation. Analyses of topographical factors can be calculated using a geographic information system (GIS) program based on digital elevation model (DEM) data. Recently, a large number of free open source software (FOSS) GIS programs are available and developed for researchers, industries, and governments. FOSS GIS programs provide opportunitiesfor flexible algorithms customized forspecific user needs. The majority of biodiversity in island areas exists at about 20% higher elevations than in land ecosystems, playing an important role in ecological processes and therefore of high ecological value. However, island areas are vulnerable to disturbances and damage, such as through climate change, environmental pollution, development, and human intervention, and lacks systematic investigation due to geographical limitations (e.g. remoteness; difficulty to access). More than 4,000 of Korea's islands are within a few hours of its coast, and 88% are uninhabited, with 52% of them forested. The forest ecosystems of islands have fewer encounters with human interaction than on land, and therefore most of the topographical conditions are formed naturally and affected more directly by weather conditions or the environment. Therefore, the analysis of forest topography in island areas can be done more precisely than on its land counterparts, and therefore has become a major focus of attention in Korea. This study is focused on calculating the performance of different topographical factors using FOSS GIS programs. The test area is the island forests in Korea's south and the DEM of the target area was processed with GRASS GIS and SAGA GIS. The final slopes and TWI maps were produced as comparisons of the differences between topographic factor calculations of each respective FOSS GIS program. Finally, the merits of each FOSS GIS program used to calculate the topographic factors is discussed.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

Comparison of the Mid-term Changes at the Remnant Distal Aorta after Aortic Arch Replacement or Ascending Aortic Replacement for Treating Type A Aortic Dissection (A형 급성대동맥박리증에서 대동맥궁치환술과 상행대동맥치환술 후 잔존 원위부 대동맥의 변화에 대한 중기 관찰 비교)

  • Cho, Kwang-Jo;Woo, Jong-Su;Bang, Jung-Hee;Choi, Pill-Jo
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.414-419
    • /
    • 2007
  • Background: Replacing the ascending aorta is a standard surgical option for treating acute type A aortic dissection. But replacing the aortic arch has recently been reported as an acceptable procedure for this disease. We compared the effects of aortic arch replacement for treating acute type A aortic dissection with the effects of ascending aortic replacement. Material and Method: From 2002 to 2006, 25 patients undewent surgical treatment for acute type A aortic dissection, 12 patients undewent ascending aortic replacement and 13 patients underwent aortic arch replacement. Among the aortic arch group, an additional distal stent-graft was inserted during the operation in 5 patients. 19 patients (11 arch replaced patients and 8 ascending aortic replaced patients) were followed up at the out patient clinic for an average of $756{\pm}373$ days. All the patients undewent CT scanning and we analyzed their distal aortic segments. Result: 4 patients who underwent ascending aortic replacement died, so the overall mortality rate was 16%. Among the 11 long term followed-up arch replacement patients, 2 patients (18.1 %) developed distal aortic dilatation and one of them underwent thoracoabdominal aortic replacement later on. However, among the 8 the ascending aortic replaced patients, 5 patients (62.5%) developed distal aortic dilatation. Conclusion: Aortic arch replacement is one of the safe options for treating acute type A aortic dissection. Aortic arch replacement for treating acute type A aortic dissection could contribute to a reduced distal aortic dilatation rate and fewer secondary aortic procedures.

Key Foods selection using data from the 7th Korea National Health and Nutrition Examination Survey (2016-2018) (제7기 국민건강영양조사 (2016-2018) 자료를 활용한 한국인의 주요 식품 (Key Foods) 선정에 관한 연구)

  • Lee, Jung-Sug;Shim, Jee-Seon;Kim, Ki Nam;Lee, Hyun Sook;Chang, Moon-Jeong;Kim, Hye-Young
    • Journal of Nutrition and Health
    • /
    • v.54 no.1
    • /
    • pp.10-22
    • /
    • 2021
  • Purpose: Key Foods refers to foods that have a high contribution in the nutrient intake of individuals, and exert important effects on their health. This study was undertaken to identify Korean Key Foods, using data from the 7th Korea National Health and Nutrition Examination Survey (KNHNES). Methods: The data source for the extraction of Key Foods was the 24-hour dietary survey data obtained from the 7th KNHNES (2016-2018), and 21,271 subjects were evaluated. A total of 17 nutrients were selected as the key nutrients for identifying the Key Foods, including energy, carbohydrates, protein, lipid, dietary fiber, calcium, phosphorus, iron, sodium, potassium, vitamin A, thiamin, riboflavin, niacin, vitamin C, cholesterol, and sugars. The nutrient consumption approach was applied to generate a list of potential Key Foods. Foods included in 85% of the cumulative intake contribution from one or more key nutrients, were subsequently selected as Key Foods. Results: Of the 1,728 foods consumed by survey respondents, we extracted 728 Key Foods. These Key Foods explained 94% key nutrient intakes of the subjects. Based on the contribution rate to key nutrient intake, the top 10 Key Foods identified were multigrain rice (5.32%), plain white rice (4.23%), milk (3.3%), cabbage kimchi (2.82%), grilled pork belly (1.56%), apples (1.52%), fried eggs (1.49%), cereal (1.36%), instant coffee mix (1.21%), and sweet potatoes (1.12%). These 10 foods accounted for 23.93% total key nutrient intake of the survey respondents. Conclusion: Seven hundred and twenty-eight foods were extracted and identified as the 2020 Korean Key Foods. These Key Foods can be considered the priority foods to be analyzed for establishing a national nutrient database.

Assessment of Nutrient and Sugar Content and pH of Some Commercial Beverages (일부 시판음료의 영양성분, 당도 및 pH 평가)

  • Jun, Mi-Kyoung;Lee, Duck-Hye;Lee, Sun-Mi
    • Journal of dental hygiene science
    • /
    • v.16 no.6
    • /
    • pp.464-471
    • /
    • 2016
  • The purpose of this study was to provide information on the labeling of nutritional components on beverages to aid in nutrition education and oral health promotion. The study was conducted to evaluate nutritional effects and risk factors associated with the consumption of different beverages with respect to oral health. A total of 52 products from seven different types of beverages were analyzed for their nutrient content, sugar content, and pH. The sugar content per serving size, based on the nutrition labeling of beverages, was highest for the milk beverages, at 26.6 g, and lowest for the teas, at 13.0 g. According to the recommendation of the World Health Organization (WHO), beverages should contain less than 10% (50 g) total sugars. Our assessment revealed that total sugars in and carbonated beverages were 53.2% and 50.0% of daily value, respectively. Therefore, the milk and carbonated beverages contained more than 50% sugars per serving size, exceeding the recommendation of WHO. The pH of the beverages, from the most acidic to the least acidic were: carbonated beverages, pH 3.0; fruit and vegetable beverages, pH 3.1; mixed beverages, pH 3.6; fruit and vegetable juices, pH 3.7; teas, pH 4.7; coffees, pH 6.6; and milk beverages, pH 6.8. The intake of acidic and sweetened beverages could potentially cause dental caries and erosion. Therefore, the results of this study could be used by oral health care professionals to counsel their patients by providing relevant information on the possibility of oral disease caused by consumption of commercial beverages.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF