• Title/Summary/Keyword: 에너지 기여도 평가

Search Result 1,107, Processing Time 0.032 seconds

Surface roughness and surface free energy components of various orthodontic adhesives (다양한 교정용 접착제의 표면거칠기와 표면에너지 요소 분석)

  • Ahn, Hyo-Beom;Ahn, Sug-Joon;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.360-368
    • /
    • 2006
  • Objective: Surface characteristics of dental materials play an important role in bacterial adhesion. The purpose of this study was to investigate surface characteristics of 5 different light-cured orthodontic adhesives (1 fluoride-releasing composite, 3 non-fluoride-releasing composites, and f resin-modified glass ionomer). Methods: Surface roughness was measured using a confocal laser scanning microscope. Contact angle and surface free energy components were analyzed using the sessile drop method. Results: Surface roughness was significantly different between adhesives despite a relatively small variation (less than $0.05\;{\mu}m$). Lightbond and Monolok2 were rougher than Enlight and Transbond XT. There were also significant differences in contact angles and surface free energy components between adhesives. In particular, considerable differences in contact angles and surface free energy components were found between resin modified glass ionomer and the composites. Resin modified glass ionomer showed significantly smaller contact angles in 3 different probe liquids and had higher total surface free energy and stronger polarity, with notably stronger basic property than the composites. Conclusion: Resin modified glass ionomer may provide a more favourable environment for bacterial adhesion than composite adhesives.

Study on Design Technology of Heat Pump Cycle for High Temperature Performance (고온 생산용 열펌프 사이클 설계)

  • Kim, Jong-Ryul;Kim, Seok-Young;Kim, Yong-Min;Lee, Kong-Hoon;Kim, Ook-Joong;Yi, Sung-Chul;Jung, Chi-Young;Kim, Jong-Ryeol
    • Journal of Energy Engineering
    • /
    • v.19 no.4
    • /
    • pp.228-233
    • /
    • 2010
  • About 55% of total energy is consumed in the industrial division. The industrial heat pump application will show magnificent energy saving effect as well as higher cost efficiency because of larger energy consuming volume of each facility and longer operation hour and higher stability against seasonal temperature change. Over 90% of dryer for industrial usage has hot wind heat source and hot wind dryer is the representative type covering 68.7% while its 30 ~ 50% lower heat efficiency causes lots of energy loss by exhaust air. Re-usage of exhaust air can improve energy efficiency of dryer because 68% heat energy or 78% of hot air lose in exhaust air. Therefore, high temperature heat pump dryer can be the best alternative. Comparing to the existing dryer with 30% ~ 50% energy efficiency, newly developing high temperature heat pump dryer will enhance energy efficiency up to 60% ~ 80% efficiency. In this paper, heat pump system for high temperature was designed, constructed and tested. The results have shown that system COPh is estimated as 3.3.

Determinations of the Exposure Rate Using a NaI(Tl) Detector of the Environmental Radiation Monitor (환경방사선감시기의 NaI(Tl) 검출기를 이용한 조사선량률 결정방법)

  • Ji, Young-Yong;Lee, Wanno;Choi, Sang-Do;Chung, Kun Ho;Kang, Mun Ja;Choi, Geun-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.3
    • /
    • pp.245-251
    • /
    • 2013
  • The energy band and the G-factor method were compared to determine the exposure rate from the measured spectrum using a NaI(Tl) scintillation detector. First, G-factors of a 3"${\Phi}X3$" NaI(Tl) detector mounted to a EFRD 3300, which means the environmental radiation monitor, in Korea Atomic Energy Research Institute (KAERI) were calculated for several directions of incident photons through the MCNP modeling, and the optimum G-factor applicable to that monitor was then determined by comparing the results both the energy band method and the G-factor method. The results for these spectrometric determinations were also compared with the dose rate from a HPIC radiation monitor around a EFRD 3300. The measured value at the EFRD 3300 based on a 3"${\Phi}X3$" NaI(Tl) detector was $7.7{\mu}R/h$ and its difference was shown about $3{\mu}R/h$, when compared with the results from a HPIC radiation moditor. Since a HPIC is known to be able to measure cosmic rays with the relatively high energy, the difference between them was caused by cosmic rays which were not detected in a 3"${\Phi}X3$" NaI(Tl) detector.

A Study on Evaluation of Safety on Two-Lane Rural Highways (지방부 2차로 안전성 평가에 관한 연구)

  • Ha, Tae-Jun;Lee, Seok
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • Purpose of this paper is proposing technical evaluation method for safety on two-lane rural highways, this method can contribute to an establishment of the safety evaluation criteria and eventually contribute to the highway safety. In this study, accident data and field data(grade, radius, speed factor) are collected and are analyzed. And new technical evaluation method is proposed by problem in review of existent methods and analysis result. Property of new method is verified by comparing with existent one. Following are results of this study. 1) Proposed technical evaluation method is Proposed by using difference of speed variance and difference of acceleration. 2) In range of field survey, proposed method is more proper than existent one by comparing. 3) Headways under 6 second affect speed of next vehicle. 4) A point with the lowest speed in curve is placed about 35m from the beginning point. 5) Correlation of speed variance and severity of highway(EPDO) is statistically significant. For using proposed method, more tests are needed on other locations with various geometries. Moreover, advanced study is needed about classifying and giving the weight of each criterion.

Fabrication Method and Performance Evaluation of Micro Igniter for MEMS Thruster (MEMS 추력기를 위한 마이크로 점화기의 제작 방법 및 성능 평가)

  • Lee, Jongkwang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Micro igniter on the glass membrane for MEMS thruster was developed. The stability of the micro igniter by using a glass membrane with a thickness of tens of microns was improved. The micro igniter was fabricated by anisotropic wet etching of photosensitive glass and deposition of Pt/Ti for electric heat coil. The solid propellant was loaded into the propellant chamber without an especial technique due to the high structural stability of the glass membrane. Ignition tests were performed successfully. The minimum ignition delay was 27.5 ms with an ignition energy of 19.3 mJ.

Effect of Detector-Misalignment on TOF-PET Detector Performance (검출기 정렬 오차가 TOF-PET 검출기의 성능에 미치는 영향성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.841-846
    • /
    • 2019
  • Effect of misalignment on the performance was evaluated for the development of time-of-flight(TOF)-PET detector. A pair of TOF-PET detector consists of Lutetium-yttrium oxyorthosilicate(LYSO) scintillation crystal with a volume of 3 mm × 3 mm × 20 mm and Geiger-mode avalanche photodiodes(GAPD) photo-sensor with a active area of 3.07 mm × 3.07 mm. Analog output signals from TOF-PET detector were sent to the pre-amplifier and then fed into the gain adjust circuit for achievement of gain homogeneity for each detector. The amplified signals were recorded and digitized by data acquisition system based on oscilloscope. The effect of the detector misalignment between LYSO and GAPD was examined for four different alignment offsets of 0.0 mm, 0.5 mm, 1.0 mm and 1.5 mm for a pair of TOF-PET detector. The photopeak position decreased from ~400 mV to ~250 mV with increasing detector misalignment. the energy resolution and time resolution were degraded from 11.6% to 16.2%, and from 477 ps to 632 ps, respectively. This study demonstrated that PET detector performance was degraded considerably depending on the detector misalignment, which would be a critical issue for the development of TOF-PET detector.

Evaluation of Applicability of Perovskite Dosimeter based on CsPbBr3 Material to Quality Assurance in Radiation Therapy (CsPbBr3을 기반으로 한 Perovskite 선량계의 방사선치료 Quality Assurance에 대한 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 2022
  • In radiation therapy, accurate Quality Assurance (QA) is required to irradiate tumor tissue while minimizing damage to normal tissue. Therefore, a dosimeter that can accurately measure radiation is needed. The purpose of this study is to develop a highly efficient radiation dosimeter with high sensitivity by applying a particle in binder method that can reduce manufacturing costs and simplify processes to perovskite materials that are cheaper and simpler to manufacture. By evaluating the response characteristics to high-energy photon, the applicability of QA dosimeter to radiation therapy was evaluated. As a result of reproducibility evaluation, RSD at 6 MV energy was presented as 1.178% and 15 MV energy was presented as 1.141%. As a result of linearity evaluation according to linear regression analysis, R2 values of 0.9999 were presented under each condition of 6 MV and 15 MV energy. It was found that the CsPbBr3 dosimeter manufactured based on the results of reproducibility and linearity evaluation is highly applicable as a QA dosimeter in the field of therapeutic radiation. The CsPbBr3 dosimeter manufactured in this study presented more than the standard performance in the evaluation of reproducibility and linearity, and it can be used as a radiotherapy QA dosimeter through improvement.

Evaluation of Tidal Stream Resources Near Uido Using an ADCIRC Model (ADCIRC 모델을 이용한 우이도 주변해역의 조류자원 평가)

  • Jeong, Haechang;Nguyen, Manh Hung;Kim, Bu-Gi;Kim, Jun-Ho;Yang, Changjo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.2
    • /
    • pp.187-193
    • /
    • 2017
  • This study evaluated tidal stream energy resources according to tidal flow properties around Uido off the west coast of, Jeollanam-do, South Korea. A feasibility study was first carried out through the collection of bathymetry data and tidal phase information. For this simulation, a depth-averaged 2D ADCIRC (Advanced Circulation) model for real sea situations was applied to a Finite Element Method (FEM) approach for tides given the variation of tidal current speed. Hydrodynamics were simulated with 4 major tidal constituents (M2, S2, K1, and O1) after setting up 4 observation points. From the real depth-averaged model simulation results, it was found that the spring tide Higher High Water (HHW) and tidal current speed values at the 4 observation points were about 2.2 m and 1.33 m/s, respectively. The ADCIRC model results were analyzed with reference to the Korea Hydrographic and Oceanographic Agency's (KHOA) observed data for verification. Furthermore, using topographical characteristics via the Tidal Flux Method (TFM), tidal energy density distribution was calculated, indicating a maximum tidal energy density of about $1.75kW/m^2$ for the 5 assessment areas around Uido. The tidal energy density was evaluated with consideration given to topographical characteristics as well as tidal elevation and tidal current speed to determine an optimum tidal farm candidate.

Biomimetic Actuator and Sensor for Robot Hand (로봇 손용 인체모방형 구동기 및 센서)

  • Kim, Baek-Chul;Chung, Jinah;Cho, Hanjoung;Shin, Seunghoon;Lee, Hyongsuk;Moon, Hyungpil;Choi, Hyouk Ryeol;Koo, Jachoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1497-1502
    • /
    • 2012
  • To manufacture a robot hand that essentially mimics the functions of a human hand, it is necessary to develop flexible actuators and sensors. In this study, we propose the design, manufacture, and performance verification of flexible actuators and sensors based on Electro Active Polymer (EAP). EAP is fabricated as a type of film, and it moves with changes in the voltage because of contraction and expansion in the polymer film. Furthermore, if a force is applied to an EAP film, its thickness and effective area change, and therefore, the capacitance also changes. By using this mechanism, we produce capacitive actuators and sensors. In this study, we propose an EAP-based capacitive sensor and evaluate its use as a robot hand sensor.

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.