• Title/Summary/Keyword: 양자검출효율

Search Result 58, Processing Time 0.408 seconds

Influence of decorrelation on phase sensitivity in a Mach-Zehnder interferometer (매개하향변환 과정에서 발생하는 두광자의 상관관계가 Mach-Zehnder 간섭계의 분해능에 미치는 영향)

  • 김헌오;고정훈;박구동;김태수
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.251-256
    • /
    • 2001
  • The influences of decorrelation on phase sensitivity are studied with a computer simulation based on the Bayesian theorem, when correlated photons produced by parametric down-conversion are incident on a Mach-Zehnder interferometer. Although the down-converted photons show a perfect correlation in the production process, this degree of correlation may be decreased by reflection, absorption, and scattering during propagation. It is found that this decorrelation results in phase sensitivity degradation, and that the sensitivity is related to the detector quantum efficiency. The results show that when the phase difference between the two paths is smaller the phase sensitivity is better. etter.

  • PDF

Background Subtraction Algorithm by Using the Local Binary Pattern Based on Hexagonal Spatial Sampling (육각화소 기반의 지역적 이진패턴을 이용한 배경제거 알고리즘)

  • Choi, Young-Kyu
    • The KIPS Transactions:PartB
    • /
    • v.15B no.6
    • /
    • pp.533-542
    • /
    • 2008
  • Background subtraction from video data is one of the most important task in various realtime machine vision applications. In this paper, a new scheme for background subtraction based on the hexagonal pixel sampling is proposed. Generally it has been found that hexagonal spatial sampling yields smaller quantization errors and remarkably improves the understanding of connectivity. We try to apply the hexagonally sampled image to the LBP based non-parametric background subtraction algorithm. Our scheme makes it possible to omit the bilinear pixel interpolation step during the local binary pattern generation process, and, consequently, can reduce the computation time. Experimental results revealed that our approach based on hexagonal spatial sampling is very efficient and can be utilized in various background subtraction applications.

Enhanced cathode luminescence in $In_xGa_{1-x}N/In_yGa_{1-y}N$ green light emitting diode structure using two-dimensional photonic crystal (2차원 광자 결정을 이용한 $In_xGa_{1-x}N/In_yGa_{1-y}N$ 녹색 발광 다이오드의 음극선 발광 효율 증대)

  • Choi, E.S.;Nguyen, H.P.T.;Doan, H.M.;Kim, S.;Lim, H.;Lee, J.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.132-133
    • /
    • 2007
  • $In_xGa_{1-x}N/In_yGa_{1-y}N$ 다중 양자우물 녹색 발광 다이오드에 2차원 광자 결정을 이용하여 음극선 발광의 향상을 관찰 하였다. 정사각형 배열의 2차원 광자 결정의 주기와 격자 상수는 200/500 nm 이고 전자빔 리소그래피로 광자결정 패턴을 제작한 후, 플라즈마 건식 식각법으로 패턴을 구현하였다. 식각 시간의 차이를 둔 구현된 패턴의 홀 깊이는, 각각 ${\sim}69nm,\;{\sim}99nm,\;{\sim}173nm$ 이었다. 전계 방사 주사 현미경 측정 결과, 형성된 홀은 끝이 잘린 역전된 원뿔 모양으로 식각 되었다. 식각 된 홀의 깊이에 따라 광자 결정이 있는 부분이 없는 부분보다 최대 ${\sim}30$배 많은 광자가 검출 됨을 확인하였다.

  • PDF

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

A study on the changes of the noise reception sensitivity in the optical system (광시스템의 잡음에 따른 수신감도 변화에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.677-682
    • /
    • 2015
  • In this paper, we investigated the effect of light on the performance of the receiver system noise and external noise added from the ever-present influence in general optical system. And calculated the reception sensitivity of the receiver at the time of off-keying transmission - from the optical transmission system in consideration of the case that the photo detector has a quantum yield of less than one-one. Not less than 50 it was confirmed that it is possible to configure the low power system is calculated and compared with the case where less than 300 the receiver sensitivity of the optical system to maintain the standard error probability. However, even if these values were considered, and the preamplifier in the receiver, considering a case of using a low-output light source, so that a heavy burden in the value less than the actual system installation, using the light source having less than the output, as shown in Figure 3, the results that were obtained also may be used.

RIE/WET Texturing구조 태양전지의 모듈 공정 전/후 특성평가

  • Seo, Il-Won;Yun, Myeong-Su;Jo, Tae-Hun;Kim, Dong-Hae;Jo, Lee-Hyeon;Son, Chan-Hui;An, Jeong-Ho;Lee, Jeong-Gyun;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.679-679
    • /
    • 2013
  • 태양전지는 계속되는 유가상승과 무소음 무공해의 녹색에너지원이라는 점에서 각광받고 있다. 더욱이 발전단가가 높기 때문에 특히 저가의 다결정 실리콘 태양전지의 연구가 활발히 진행되고 있다. 태양전지의 texturing 공정은 광 포획 효과를 극대화 시킨다. 이에 따라 웨이퍼 표면에 텍스쳐를 형성하여, 광학적 손실을 줄이는데, 일반적으로 alkaline etching (WET) 공정과 reactive ion etching (RIE) 공정이 사용된다. 본 연구에서는 RIE, WET 공정을 사용하여 만든 texturing 구조의 태양전지를 모듈 공정 진행 전 특성평가를 한 후 다시 모듈 공정 후 특성평가를 진행하였다. 특성평가는 태양전지의 전류-전압 곡선을 통해 개방전압, 단락전류, 곡선인자 을 측정하고, 파장에 따른 양자효율 및 반사율을 측정하였다. 또한 태양전지의 전기에너지를 가하여 생성되는 전계발광 현상과 NIR camera를 이용하여 Grain의 Dark Area 및 Micro crack을 검출하였다. 이와 같은 모듈 공정 전/후 특성을 측정하고, 이를 비교 분석하여 BIPV 적용 시 태양전지의 동작특성을 확인하였다.

  • PDF

유기 금속 화학 증착법에 의한 Si 기판 위에 GaP 층 성장시 에피의 초기 단계의 성장 매개 변수에 영향

  • Gang, Dae-Seon;Seo, Yeong-Seong;Kim, Seong-Min;Sin, Jae-Cheol;Han, Myeong-Su;Kim, Hyo-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.209.1-209.1
    • /
    • 2013
  • GaP는 가시광선 발광다이오드을 얻을 수 있는 적절한 재료중의 하나로 해당영역의 파장에 대하여 높은 양자효율을 얻을 수 있고, 깊은 준위 재결합이 없기 때문에 GaP 녹색 및 As 첨가한 GaAsP 적색 LED 에 적용할 수 있습니다. 또한, 상온에서 2.2 eV 에 해당하는 넓은 에너지 밴드갭을 가지고 있으므로, 소음이 없는 자외선 검출기에도 적합합니다. 이 물질에 대한 소자들은 기존에 GaP 기판을 사용하였습니다. 최근, GaP 와 격자상수가 비슷한 Si 기판을 활용하여 그 위에 성장하는 방법에 대한 관심이 많아졌습니다. Si는 물리적 및 화학적으로 안정하고 딱딱한 소재이며 대면적 기판을 쉽게 얻을 수 있어 전자 기기 및 대규모 집적 회로의 좋은 소재입니다. Si 와 대조적으로 GaP은 깨지기 쉬운 재료이며 GaP 기판은 Si와 같은 대면적 기판을 얻을 수 없습니다. 이러한 문제의 한 가지 해결책은 Si 기판위에 GaP 층의 성장입니다. GaP 과 Si의 조합은 현재의 광전소자 들에 더하여 더 많은 응용프로그램들을 가능하게 할 것입니다. 그러나, Si 기판위에 GaP 성장 시 삼차원적 성장 및 역위상 경계면과 같은 문제점들이 발생하므로 질이 높고 균일한 결정의 GaP 를 얻기가 어렵습니다. 따라서, Si 에 GaP 의 성장시 초기 단계를 제어하는 성장 기술이 필요합니다. 본 연구에서는, 유기금속화학증착법을 이용하여 Si 기판위에 양질의 GaP를 얻을 수 있는 최적의 성장조건을 얻고자 합니다. 실험 조건은 Si에 GaP의 에피택셜 성장의 초기 단계에 영향을 주는 V/III 비율, 성장압력, 기판방향 등을 가변하는 조건으로 진행하였습니다. V/III 비율은 100~6400, 성장 압력은 76~380 Torr로 진행하였고, Si 기판은 just(001)과 2~6도 기울어진 (001) 기판을 사용하였습니다.

  • PDF

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.