• Title/Summary/Keyword: 액체공기

Search Result 284, Processing Time 0.03 seconds

Recovery of Silicon from Silicon Sludge by Electrolysis (실리콘 슬러지로부터 실리콘의 전해회수(電解回收))

  • Park, Jesik;Jang, Hee Dong;Lee, Churl Kyoung
    • Resources Recycling
    • /
    • v.21 no.5
    • /
    • pp.31-37
    • /
    • 2012
  • As a recovery of elemental silicon from the sludge of Si wafer process, a process of mechanical separation-chlorine roasting-electrolysis has been suggested. The silicon sludge consisted of Si, SiC, machine oil, and metallic impurities. The oil and metal impurities was removed by mechanical separation. The Si-SiC mixture was converted to silicon chloride by chlorine roasting at $1000^{\circ}C$ for 1 hr and the silicon chloride was dissolved into an ionic liquid of $[Bmpy]Tf_2N$ as an electrolyte. Cyclic voltammetry results showed an wide voltage window of pure $[Bmpy]Tf_2N$ and a reduction peak of elemental Si from $[Bmpy]Tf_2N$ dissolved $SiCl_4$ on Au electrode, respectively. The silicon deposits could be prepared on the Au electrode by the potentiostatic electrolysis of -1.9 V vs. Pt-QRE. The elemental silicon uniformly electrodeposited was confirmed by various analytical techniques including XRD, FE-SEM with EDS, and XPS. Any impurity was not detected except trace oxygen contaminated during handling for analysis.

Optimization of $CO_2$ Direct Absorption Method for the Determination of Carbon-14 in Environmental Samples (환경시료중의 방사성탄소 측정을 위한 $CO_2$ 직접흡수법의 최적화 연구)

  • Cho, Soo-Young;Woo, Hyung-Joo;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.237-242
    • /
    • 1998
  • The goal of this work was to optimize the liquid scintillation counting techniques for the determination of C-14 in environmental samples such as biological and air samples. Carbon-14 activities in most environmental samples were measured with direct $CO_2$ absorption method. The highest figure of merit was found through the variation of Carbosorb $E^{TM}$ and Permatluor $V^{TM}$ ratio, in the measurement windows. The best condition was 1:1 volume ratio. Average 2.35 g of $CO_2$ was reproducibly absorbed in the 20 ml mixture within 40 min. The counting efficiency determined by repeated analysis of NIST oxalic acid standard and the background count rate were measured to be $58.8{\pm}1.4%$ and $1.88{\pm}0.06\;cpm$, respectively in case of saturated solution. The correction curves of counting efficiency for partially saturated solutions and for saturated solutions with quenching were prepared, respectively. The overall uncertainty of the sample specific activity for near background levels was estimated to be about 7 % for 4 hours counting at 95 % confidence level. The long-term stability of samples has been checked for all the counting techniques over a two week periods, and no apparent change in counting efficiency and background level was found at that time.

  • PDF

Uranium Recovery from Nuclear Fuel Powder Conversion Plant Filtrate and its Thermal Decomposition Characteristics (핵연료분말 제조공정에서 발생된 여액으로부터 우라늄 회수 및 회수된 우라늄 화합물의 열분해 특성)

  • Jeong, Kyung-Chai;Jeong, Ji-Young;Kim, Byung-Ho;Kim, Tae-Joon;Choi, Jong-Hyeun
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.2
    • /
    • pp.204-209
    • /
    • 2002
  • In this study, $UO_4{\cdot}2NH_4F$, the precipitates which has low solubility, was obtained by chemical precipitation method to recover and reuse the trace uranium from the liquid waste producing in AUC process and for this compound it was characterized by means of chemical analysis, TG-DTA, XRD and FT-IR analyses. This compound was analyzed as $UO_4{\cdot}2NH_4F$ and shape of this precipitate was hexagonal type, having the size of 2∼3 ${\mu}m$. Also, the intermediates were obtained as $UO_4F,\;UO_4,\;UO_3,\;and\;U_3O_8$ by the thermal decomposition over the temperature of 220, 310, 515 and 640$^{\circ}C$, respectively. It is concluded that under the condition of a constant heating rate of 5$^{\circ}C$/min in air atmosphere range of between room temperature and 800$^{\circ}C$, thermal decomposition reaction mechanism of $UO_4{\cdot}2NH_4F$ is as follow; $UO_4{\cdot}2NH_4F{\rightarrow}UO_4F{\rightarrow}UO_4{\rightarrow}UO_3{\rightarrow}U_3O_8$.

EFFECT OF CURING CONDITIONS ON THE MONOMER ELUTION OF ORTHODONTIC ACRYLIC RESIN (교정용 아크릴릭 레진의 중합조건에 따른 모노머 용리)

  • Noh, Hong-Seok;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.477-486
    • /
    • 2008
  • Acrylic resin is widely used in dental practice. However, the residual monomer in acrylic resin could act as a negative biocompatability on human body. The aim of this study was to evaluate the amount of the monomer elution from polymerized orthodontic acrylic resin. Orthodontic acrylic resin was used in the study. The curing condition of the resin was controlled by temperature, pressure, aquatic and atmospheric environment. The duration and amount of monomer elution and timedependent plot was recorded by high performance liquid chromatography. The result showed that the only monomer eluted from the resin was methyl methacrylic acid. And the amount of the monomer elution has diminished considerably by time progress especially within 24 hours. Furthermore, elution of the residual monomer was significantly lower in group of pressure, moisture and elevated temperature than control (p<.05). According to this study, it was thought that the elution of residual monomer might be influenced by curing environment.

  • PDF

Klebsiella Pneumonia-Necrotizing Fasciitis followed by Liver Abscess (폐렴 간균-괴사성 근막염에 이어 발생한 간농양)

  • Lee, Seung Hyun;Choi, Jeong Woo;Lee, Myeung Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.427-431
    • /
    • 2018
  • We report a case of a patient with necrotizing fasciitis followed by liver abscess. A 51-year-old man was admitted to our hospital with a 5-day history of fever and chills with painful swelling of the right thigh. A magnetic resonance imaging (MRI) scan showed fluid collection with numerous dark signal intensities considered as air-bubbles between the posteromedial and posterolateral groups of the right thigh, resulting in presumptive diagnosis of necrotizing fasciitis. At the time of admission, an ultrasonograph of the abdomen showed increased parenchymal echogenicity of both kidneys and no liver abscess. Ten days after fasciotomy, an abdominal computed tomography (CT) scan showed intrahepatic abscess. Sonography-guided percutaneous drainage was performed. Both cultures of pus specimens from the liver abscess and right thigh yielded Klebsiella pneumoniae (K. pneumoniae). The patient was treated with fasciotomy several times and parenteral antibiotics, after which he began to improve. After 5 weeks, liver abscess size was reduced, and after 10 weeks, liver abscess disappeared. To the best of our knowledge, this is the first case of K. pneumoniae-necrotizing fasciitis followed by liver abscess.

Absorbed Dose for the Endovascular Ho-166-DTPA Brachytherapy Using a Balloon Angio Catheter (풍선도자관의 Ho-166-DTPA 흡수선량)

  • 조철우;박찬희;윤석남;강해준;김미화;장지선;박경배
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.98-103
    • /
    • 2002
  • The purpose of this study was to evaluate the absorbed dose to the coronary artery segment from various sized balloon angio catheters. The liquid form of Ho-166 was produced at the KAERI by (n, ${\gamma}$ ) reaction. We used GafChromic film for the estimation of the absorbed dose by beta particles. The exposed films were read using a videodensitometer. Several film exposures were made with varying irradiation times and activities. A modified micrometer was used for the measurement of the absorbed dose distribution near the balloon surface. Four balloons of coronary catheters evaluated were 30 m long and 2.5, 3.0, 3.5 and 4.0 mm in diameter. All doses are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 0.86, 1.01, 1.11 and 1.24 Gy/min/GBq/ml at a balloon surface for various balloon diameter 2.5, 3.0, 3.5 and 4.0 mm respectively. Using a vacuum pump, the air in the balloon was evacuated prior to instillation of the Ho-166 source. By removing air bubbles in the balloon, the absorbed dose distribution was more uniform.

  • PDF

Flame Instability in Heptane Pool Fires Near Extinction (소화근처 헵탄 풀화재의 화염불안정성)

  • Jeong, Tae Hee;Lee, Eui Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1193-1199
    • /
    • 2012
  • A cup burner experiment was performed to investigate the effect of the oxidizer velocity and concentration on flame instability near extinction. Heptane was used as a fuel and air diluted by nitrogen and carbon dioxide was used in the oxidizer stream. Two types of flame instabilities at the flame base and at axial downstream were observed near extinction. The instability at the flame base could be characterized by cell, swing, and rotation modes, and the cell mode changed to the rotation mode through the swing mode as the oxidizer velocity increased. To assess the parameters for the flame instability, the initial mixture strengths, Lewis number, and adiabatic flame temperature were investigated under each condition. The Lewis number might be the most important among them, but it is impossible to generalize because of the insufficient number of cases. Furthermore, the axial periodic flickering motion disappeared at low and high oxidizer velocities near extinction. This resulted from the fact that low oxidizer velocity induced evaporated fuel velocity below the critical velocity and high velocity made the reacting fuel velocity comparable.

Numerical Analysis on Heat Gain of Liquid from Ambient Air with Various Fin Heights and Pitches of Fin-and-Tube Heat Exchanger in Hybrid Solar Collector (핀-튜브 열교환 구조를 갖는 복합집열기에서 핀 높이 및 간격에 따른 공기열 이용 액체 가열 성능에 관한 수치해석 연구)

  • Choi, Hwi-Ung;Fatkhur, Rokhman;Lyu, Nam-Jin;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.53-61
    • /
    • 2016
  • Solar assisted heat pump system uses solar thermal energy as a heat source of evaporator of heat pump. So, COP can be enhanced as well as collector efficiency. For improving performance of this system, some research about hybrid solar collector that has fin-and-tube heat exchanger has been conducted. This collector can get a thermal energy from ambient air for liquid heating, so heated liquid can be used as a heat source of evaporator in heat pump even the solar radiation is not enough. In this study, numerical analysis was conducted for confirming heat gain of liquid according to fin height and pitch of fin-and-tube heat exchanger in collector. As a result, higher heat gain was obtained on lower fin height and narrow fin pitch, but the pressure drop also increased with increment of heat gain. Thus the JF factor considering both heat transfer enhancement and pressure drop was investigated and the maximum value was shown when the fin height and pitch were 40mm and 45mm. So it is considered that this installation condition has a highest heat transfer improvement when comparing with pressure drop. However heat gain of liquid at this condition was less than the other installation conditions of fin pitch on same height. Then, after establishing a proper minimum heat gain of liquid, actual production and experiment of collector will be conducted with fin height and pitch showing maximum JF factor and satisfying selected minimum heat gain of liquid on the basis of results of this study.

Elli-Situ 2000 (in situ, 실시간 표면 및 박막 모니터 장비)

  • 방현용;주한용
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.46-46
    • /
    • 2000
  • 과학기술 및 산업의 발달로 인하여 실험 중 또는 공정 상에서 in situ, 실시간으로 측정하고 분석하며 이를 되먹임하는 품질제어의 중요성이 대두되고 있다. 반도체 공정 또는 박막제조 공정 중에서 박막의 두께, 굴절율, 물질의 조성비 등을 알아내는 것이 긴요한 과제로 대두되고 있으며, 이를 위하여 공정중인 제품의 품질을 실시간으로 평가하는 장비가 요구되고 있는 것이다. 나아가 공정중의 예상하지 못한 시료의 특성변화를 그대로 감지하여 적절히 보정해 주는 되먹임 기법은 높은 수율을 보장하는 첨단기법이라 할 수 있다. 이러한요구에 부응할 수 있는 본 제품(Elli-situ 2000)은 박막의 두께 표면변화를 sub 의 정밀도를 가지고 in situ, 실시간으로 정밀 측정할 수 있는 첨단 계측장비로서 빛의 편광상태 변화를 측정하기 때문에 공정 중의 시료에 영향을 주지 않는 비간섭 특성과 비접촉 특성의 장점 뿐만 아니라 공기중에서는 물론 진공이나 액체 등의 매질에서도 사용될 수 있어서 매질에 대한 제약이 거의 없다는 장점도 가지고 있다. 편광상태의 제어 및 측정을 필요한 광학장비의 경우, 제작이 까다롭기 때문에 대부분 가격이 높은 편이고 사용방법이나 측정 데이터에 대한 해석이 어렵다는 단점이 있으나, Elli-situ 2000의 경우 상용화된 외국제품(국내제품은 없슴)과 비교하여 성능 및 가격경쟁력에 있어서도 우위에 있으며 간단, 명료한 장비조작 및 컴퓨터를 사용한 구동의 전자동화를 이룸으로써 초보자도 쉽게 측정하고 데이터를 처리할 수 있도록 하였다. 또한 취부대의 경우, 진공포트 플랜지의 표준규격(2-3" Del-Seal 플랜지 규격)에 맞춤으로써 기존의 진공챔버에 부착하여 진공에 전혀 영향을 주지 않는 상태에서 시료의 변화를 in situ, 실시간으로 정밀 측정할 수 있도록 하였다. 하였다.O 박막은 산소 가스압력과 기판온도, 인가 전류를 변화시켜가며 증착하였으며 이에 따른 박막의 결정성 변화를 알아보았다. 기판온도를 실온에서 점차 증가시켜나가면 $\Delta$$\theta$50은 급격히 감소하며 30$0^{\circ}C$에서는 결정성이 우수한 막을 얻을 수 있었다. 또한 산소 가스 압력이 0.5~1mTorr에서 $\Delta$$\theta$50은 양호한 값을 나타내었지만 그 이상에서는 c-축 배향성이 나빠짐을 확인하였다. 따라서 대향타겟식스퍼터 장치를 이용하여 ZnO 박막을 증착시 가스압력 0.5~1mTorr, 기판온도 20$0^{\circ}C$이상의 막 제작조건에서 결정성이 우수하게 나타나는 것을 확인할 수 있었다. gluten이 단단해졌음을 알수 있었다. 유화제 stearly 칼슘, 혹은 hemicellulase를 amarans 10% 대체한 밀가루에 첨가하면 확연히 비용적을 증대시킬 수 있다는 사실을 알 수 있었다. quinoa는 명아주과 Chenopodium에 속하고 페루, 볼리비아 등의 고산지에서 재배 되어지는 것을 시료로 사용하였다. quinoa 분말은 중량의 5-20%을 quinoa를 대체하고 더욱이 분말중량에 대하여 0-200ppm의 lipase를 lipid(밀가루의 2-3배)에 대하여 품질개량제로서 이용했다. 그 결과 quinoa 대량 7.5%에서 비용적, gas cell이 가장 긍정적 결과를 산출했고 반죽의 조직구조가 강화되었다. 또 quinoa 대체에 의해 전분-지질 복합제의 흡열량이 증대된 것으로부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다. 이것은

  • PDF

Effects of Freezing-Thawing Conditions on Physicochemicnl and Histological Properties of Plaice, Paralichthys olivaceus Muscle (동결-해동 조건이 넙치육의 물리$\cdot$화학적 및 조직학적 변화에 미치는 영향)

  • CHO Young-Je;CHO Min-Sung;LEE Nam-Gul;CHOI Young-Jun;KIM Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.463-470
    • /
    • 1998
  • To improve muscle quality and prolong freshness of sashimi, the effects of freezing-thawing condition on physicochemical and rheological properties of plaice muscle were investigated. Muscle tested were frozen with quick freezing (liquid nitrogen gas) or slow freezing ($-15^{\circ}C$ air). Transition time of zone of ice crystal formation was within 10 minute for quick freezing and 110 minute for slow freezing. Time required for thawing to $0^{\circ}C$ in muscle temperature by various thawing methods was shortest with $25^{\circ}C$ tap water, followed by $15^{\circ}C$ tap water, $10^{\circ}C$ tap water, $25^{\circ}C$ air, $5^{\circ}C$ tap water and $0^{\circ}C$ cold water. Breaking strength of muscle was higher in quickly frozen sample than in slowly frozen sample. According to sashimi term, changes in breaking strength of muscle did not show any difference in quickly frozen sample, while showed significant difference in slowly frozen sample. The remaining content of ATP was not effected by freezing speed, and ATP content was apt to higher in quickly thawed sample than in slowly thawed sample. IMP was the majority of ATP and it's related compounds of sample after freezing and thawing. Collagen matrix was weakened markedly in slowly frozen sample than in quickly frozen sample.

  • PDF