• Title/Summary/Keyword: 액체공기

Search Result 284, Processing Time 0.024 seconds

A Study on the Liquid-level Sensors Using Splitting Ratio of Fiber-optic Directional Couplers (광섬유형 방향성 결합기의 광 분배비를 이용한 수위 센서 연구)

  • Sohn, Kyung-Rak;Key, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.846-851
    • /
    • 2010
  • A liquid-air interface sensing system using the flat end surfaces of a fused-silica fiber coupler has been demonstrated. The principle is based on the additional optical loss caused by changing the refractive index of the external material at the boundary of the end face made of a fiber. The immersion characteristics of this system with respect to the different splitting ratios of the couplers were investigated to determine the sensitivity when it responses to water and air. These experimental data are very useful for selecting the coupling ratio of a coupler in order to develop a multiple sensing probe system. In the proposed sensor structure, it can be emphasize that the sensing probe can be appropriately arrayed on the basis of splitting ratio of the coupler. As a result, it is expected that the proposed liquid-air interface sensors can also be applied to monitor flooding that occurs in multiple areas at the same time.

Experimental Study on the Two-Stage Light-Gas Gun (2단 경가스총에 대한 실험적 연구)

  • Lee, Jung-Kuen;Lee, Jong-Sung;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.345-348
    • /
    • 2010
  • Light gas guns have a large number of applications in various fields of engineering. A two-stage light gas gun can develop an extremely high pressure in a very short interval of time. This can be employed efficiently in the application of ultra-high pressure liquid jets. In general, the two-stage light gas gun is made up of a high pressure tube, a compression tube and a launch tube, each stage being separated by diaphragms. The first diaphragm is installed downstream of the high pressure tube and the second, downstream of the compression tube. In the present study, experiments are carried out to investigate the projectile velocity and pressure behavior in the tubes according to the pressure changes at diaphragm opening. It is found that the rupture pressure of the first diaphragm has a dominant influence on projectile velocity. It is also observed that at pressures greater than 14 bar, the pressure in the launch tube exceeds that in the compression tube.

  • PDF

Cleaning and Decontamination Method of Books for Their Sanitary Circulation (책의 위생적 유통관리를 위한 세정 소독 방법)

  • Kim, Nam Yong;An, Duck Soon;Choi, Young Il;Jung, Yong Bae;Kim, Jung Min;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • In order to find a sanitary logistic way to handle library books, papers and environmental sources contacting the books were tested in their microbial contamination load and methods to decontaminate the books were investigated. Generally bacterial load of inner book pages was very low, but increased when contaminated with liquid such as saliva. In contrast, their lateral ends showed much higher bacterial contamination presumably due to dry dust contamination on there. As operations to improve the sanitary book conditions, turbulent air blow was found to be workable for reducing dry dusty contamination and 280 nm ultra-violet (UV) light emitting diode (LED) was so for decontaminating wet surface contamination. Microbial inactivation by the UV LED could be realized with irradiation for more than 5 minutes at 2 cm distance. Air blow of 5.5 m/s for 0.5~1 minute could reduce the dusty contamination on a model book surface.

  • PDF

Experimental Study on a Two-Stage Light-Gas Gun (2단 경가스총에 대한 실험적 연구)

  • Lee, Jung-Keun;Kim, Heuy-Dong;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.4
    • /
    • pp.10-15
    • /
    • 2010
  • Light gas guns have a large number of applications in various fields of engineering. A two-stage light-gas gun can produce an extremely high pressure in a very short interval of time. In general, the two-stage light-gas gun is made up of a high pressure tube, a compression tube and a launch tube, each stage being separated by diaphragms. This can be employed efficiently in the application of ultra-high pressure liquid jets. In the present study, experiments are carried out to investigate the projectile velocity and pressure behavior in the tubes according to the pressure changes at the frist diaphragm opening. In the present study result was found that the rupture pressure of the first diaphragm has a dominant influence on piston acceleration.

Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method (삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석)

  • Lim, Hyun Oh;Lim, Dae Ho;Seo, Myung Jae;Kang, Yong;Jung, Heon;Lee, Ho Tae
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.605-610
    • /
    • 2011
  • Phase holdup characteristics of relatively large and small bubbles were investigated in a three-phase(gasliquid-solid) fluidized bed of which diameter was 0.105 m(ID) and 2.5 m in height, respectively. Effects of gas(0.01~0.07 m/s) and liquid velocities(0.01~0.07 m/s) and particle size($0.5{\sim}3.0{\times}10^{-3}m$) on the holdups of relatively large and small bubbles were determined. The holdups of two kinds of bubbles in three phase fluidized beds were estimated by means of static pressure drop method with the knowledge of pressure drops corresponding to each kind of bubble, respectively, which were obtained by dynamic gas disengagement method. Dried and filtered air which was regulated by gas regulator, tap water and glass bead of which density was $2500kg/m^3$ were served as a gas, a liquid and a fluidized solid phase, respectively. The two kinds of bubbles in three-phase fluidized beds, relatively large and small bubbles, were effectively detected and distinguished by measuring the pressure drop variation after stopping the gas and liquid flow into the column as a step function: The increase slope of pressure drop with a variation of elapsed time was quite different from each other. It was found that the holdup of relatively large bubbles increased with increasing gas velocity but decreased with liquid velocity. However, the holdup showed a local minimum with a variation of size of fluidized solid particles. The holdup of relatively small bubbles increased with an increase in the gas velocity or solid particle size, while it decreased slightly with an increase in the liquid velocity. The holdups of two kinds of bubbles were well correlated in terms of operating variables within this experimental conditions, respectively.

Characteristics of Wakes in a Viscous Liquid Medium of a Simulated GTL Process (모사된 GTL공정의 점성액체 매체에서 wake의 특성)

  • Lim, Dae Ho;Jang, Ji Hwa;Kang, Yong;Jun, Ki Won
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.571-576
    • /
    • 2011
  • Characteristics of bubble driven wakes were investigated in a simulated GTL process(0.102 m ${\times}$ 1.5 m in height) with viscous liquid medium. Effects of gas velocity(0.04 ~ 0.12 m/s) and liquid viscosity(0.001 ~ 0.050 $Pa{\cdot}s$) on the wake characteristics such as rising velocity, frequency, size and holdup were determined by employing a resistivity probe method. The wake phase formed behind the rising multi-bubbles as well as single bubbles were detected effectively from the conductivity fluctuations measured by the probe. Compressed, filtered and regulated air and aqueous solutions of Carboxy Methyl Cellulose(CMC) were used as a dispersed gas phase and a continuous liquid medium, respectively. It was found that the rising velocity and size of wake phase increased with an increase in gas velocity or liquid viscosity. The holdup and frequency of wake phase increased with increasing gas velocity due to the increase of gas input into the process with increasing gas velocity. However, the values of holdup and frequency of wake phase decreased with increasing liquid viscosity, since the size of bubbles and thus that of wakes increased with increasing liquid viscosity. The ratio of wake holdup to that of gas phase, which was in the range of 0.25 ~ 0.48, increased with an increase in liquid viscosity but decreased with gas velocity. The wake characteristics were well correlated in terms of operating variables within this experimental conditions.

Comparison of the Dehumidification Performance Between LiCl and LiBr in a Liquid Desiccant Dehumidifying Element Having Criss-Cross Sinusoidal Channels (Celdek) (교차 적층된 파형 액체 제습 소자 (Celdek)에서 LiCl과 LiBr 수용액의 제습 성능 비교)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.27-34
    • /
    • 2018
  • Recently, liquid desiccant systems have received attention for the dehumidification of air. LiCl and LiBr are widely used in liquid desiccant systems due to their excellent thermo-physical properties. In this study, dehumidification tests were conducted with Celdek elements using LiCl and LiBr. During the tests, the dry and wet-bulb air temperatures were maintained at $35^{\circ}C$ and $28^{\circ}C$, respectively. The solution temperature was $20^{\circ}C$, the solution concentration was 50%, the solution circulation rate was 50 kg/h, and the frontal air velocity was varied from 2.0 to 4.0 m/s. The results show that the amount of dehumidification increased as the frontal velocity increased. On average, LiCl showed 27% higher dehumidification performance than LiBr, which was probably due to the lower saturation of the absolute humidity of LiCl compared with that of LiBr. On the other hand, LiBr yielded 12% larger pressure drop than LiCl. In general, the Sherwood numbers of LiCl and LiBr were approximately the same, showing that the effect of the desiccant on the Sherwood number was insignificant. Existing correlations highly overpredicted the present Sherwood numbers.

Design and fabrication of a RFID Reader Antenna in 900MHz Band (900MHz 대역 RFID 리더기 안테나 설계 및 제작)

  • Kim, Chan-Baek;Park, Seong-Il;Ko, Young-Hyuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.125-128
    • /
    • 2008
  • In this paper, a stand-type planar antenna of 900MHz RFID band is designed and fabricated. As the proposed antenna is stand-type use of air permittivity, Bandwidth used ground height at rectangle patch structure and coaxial feed line is widen. Also wideband width can solve problem that RFID tag attached to things happens frequency shift keying phenomenon by liquid, special metal, temperature, humidity etc. Bandwidth of fabricated antenna to VSWR less than 2 is satisfied 11.9% at $890MHz{\sim}1000MHz$. And proposed antenna is circular polarization antenna of operating characteristics that axial ratio is less than 2 and gain is 6dBi.

  • PDF

A Study on the Radial Spray Performance of a Plaint-Jet Twin-Fluid Nozzle (액주형 이류체노즐의 반경반향 분무특성에 관한 연구)

  • 최진철;노병준;강신재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.662-669
    • /
    • 1994
  • In the combustion system, the optimum spray conditions reduce the pollutant emission of exhaust gas and enhance the fuel efficiency. The spray characteristics-the drop size, the drop velocity, the number density and the mass flux, become increasingly important in the design of combustor and in testifying numerical simulation of spray flow in the combustor. The purposes of this study are to clarify the spray characteristics of twin-fluid nozzle and to offer the data for combustor design and the numerical simulation of a spray flow. Spatial drop diameter was measured by immersion sampling method. The mean diameter, size distribution and uniformity of drop were analyzed with variations of air/liquid mass flow ratio. The results show that the SMD increases with the liquid supply flow rate and decreases with the air supply velocity. The radial distribution of SMD shows the larger drops can diffuse farther to the boundary of spray. And the drop size range is found to be wider close to the spray boundary where the maximum SMD locates.

Ignition Characteristics of JP-7 as a Scramjet Fuel (스크램제트 연료로써 JP-7 의 점화 특성)

  • Choi Jeong-Yeol;Puri Puneesh;Ma Fuhua;Yang Vigor
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.377-380
    • /
    • 2005
  • A study of ignition characteristics of cracked JP-7 fuel with both oxygen and air has been conducted over a wide range of pressures (1-20 atm), temperatures (1200-2000 K), and equivalence ratios (0.5-1.5). Correlations of ignition delay, of the form, $\tau=Aexp(E/RT)[F]^{a}[O_2]^{b}$ are established using the Chemkin-II package and least square analysis. The effect of $C_3$ hydrocarbons in cracked JP-7 fuel is examined by comparing the ignition delays for two different cracked compositions. A comparison for ignition delay is also made with the experimental results obtained by injecting liquid JP-7 fuel in air using a shock tube apparatus.

  • PDF