• Title/Summary/Keyword: 압축인장강도

Search Result 769, Processing Time 0.021 seconds

Effects of CR Contents on Rubber Vulcanization and Mechanical Properties of NR/CR Blends (NR/CR 고무블랜드에서의 CR조성비가 가황 및 물성에 미치는 영향)

  • Ahn, Won-Sool;Park, Dong-Ryul
    • Elastomers and Composites
    • /
    • v.46 no.2
    • /
    • pp.152-157
    • /
    • 2011
  • Effects of CR contents in NR/CR blends on the vulcanization kinetics and miscibility were studied by dynamic DSC and TGA, as well as the mechanical properties. While the vulcanization activation energy showed a constant value of $77.5{\pm}2.5$ kcal/mol regardless of CR contents, reaction rate, however, was observed to be somewhat lowered at increased CR contents. Partial miscibility was found between NR and CR phases at lower CR content of 3 wt%, but immiscibility was observed at higher CR content of 21 wt%. Mechanical properties were also affected by this miscibility, showing linear increase of compression set but decrease of tensile strength with CR contents in the blends.

Characterization of Cast-Forging Process in Hypereutectic Al-15wt.%Si alloy

  • Kim, Eok-Soo;Lim, Kyung-Mook;Hong, Young-Myung;Han, Yoon-Sung;Lee, Kwang-Hak
    • Journal of Korea Foundry Society
    • /
    • v.27 no.5
    • /
    • pp.212-216
    • /
    • 2007
  • 과공정 Al-15wt.%Si 합금의 주단조 공정의 적용을 위해 주조 예비성형체를 제작하는 과정에서 P와 Sr을 첨가하여 과공정 Al-Si 합금의 응고과정에서 발생하는 초정 Si과 공정 Si의 미세화 개량처리를 행하였다. 미세화 조직의 변화에 따른 기계적성질 및 단조성을 조사하였으며, 미세화제로 첨가된 0.075wt.% Sr과 0.1wt.% P의 첨가에서 가장 효과적인 미세한 조직을 얻을 수 있었고, 인장강도와 연신율은 이들 첨가원가의 증가에 따라 향상되는 결과를 보였으나 일정 이상의 첨가에서는 더 이상의 향상은 없었다. 단조성 평가를 위한 열간가공 재현실험에서는 $450^{\circ}C$에서 약60N/mm2의 하중이 필요함을 알 수 있었다. 열간단조 및 열처리 후의 인장강도와 연신율은 보다 많은 향상을 가져왔으며, 이는 압축가공에 의한 주조 예비성형체 내부에 잔존하던 주조결함의 제어와 열처리에 의한 조직의 개량 및 균질화 효과에 의한 것으로 판단된다.

Study on Plastic Fiber Coating Materials (플라스틱 직물 코팅재료에 관한 연구)

  • 김동학;김태완
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Liquid PVC, which is used widely as fiber coating, has brilliant non-luster effect, but it decreases flexibility of coated fiber surface. We used liquid silicone rubber in elastomer series as a coating material to alleviate this problem. We have conducted the former liquid PVC processing and used pressure of roller and preliminary hardening of processing. In this experiment, We measured 70 degree of hardness, 10.3 MPa of tensile strength and 200fs of tensile elongation of Liquid PVC-coated plastic fiber. We measured 40 degree of hardness, 5.1 MPa of tensile strength and 460% of tensile elongation of Liquid silicone PVC-coated plastic fiber. Therefore, Without the second process, Liquid silicone rubber coating increased non-luster effect and flexibility of plastic fiber surface more than Liquid PVC coating.

  • PDF

The Influence of Mechanical Properties with the Number of Recycling of Fiber-reinforced Thermoplastic Composites Damaged by Impact (충격에 의해 손상된 섬유강화 열가소성 수지 복합재료의 재활용 횟수에 따른 물성의 변화)

  • Bae, Kwak Jin;Lee, Joon Seok
    • Composites Research
    • /
    • v.35 no.2
    • /
    • pp.75-79
    • /
    • 2022
  • In this study, the effect of mechanical and chemical properties of glass fiber reinforced thermoplastic (GFRTPs) according to the number of recycling was confirmed. The composite materials were manufactured through a hot press compression molding process using an E-glass chopped strand mat and a polypropylene film. Four specimens were named according to the number of recycled test repeat: First manufacture, 1st Recycle, 2nd Recycle, and 3rd Recycle. To investigate the mechanical properties of the prepared specimen, tensile test, flexural test, drop-weight impact test, differential scanning calorimetry (DSC), and field emission electron gun-scanning electron microscope (FE-SEM) was performed. As a result, as the number of recycling steps repeat, the degree of crystallization, tensile strength, elastic modulus, and flexural strength were increased, but the impact properties were greatly reduced.

Evaluation of weld joint properties with length of inserted short pipe at the time of pipeline welding (배관용접시 단관삽입길이에 따른 용접부 특성 평가)

  • Kim Cheol-man;Kim Woo-sik;Kim Young-seob;Kwon Jeong-rock
    • 한국가스학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.53-58
    • /
    • 2003
  • API 5L X65 배관에 50mm이상의 단관을 삽입하여 용접하였을 경우, 삽입된 단관 길이 변화에 따른 용접부 기계적 특성 평가 결과를 요약하면 다음과 같다. 1. 단관삽입 용접부위의 거시적 조직관찰, 미소경도측정, 인장시험, 굽힘시험을 수행한 결과, 단관삽입 용접부의 건전성에는 문제가 없는 것으로 평가되었다. 2. 단관삽입 용접부의 원주방향 최대 인장 잔류응력의 크기는 단관 삽입 길이에 관계없이 약 150MPa로서 그리고 최대 압축 잔류응축은 약 300MPa로 측정되었다. 모재의 항복강도가 492MPa인 것과 비교하여보면 단관 삽입 용접에 의한 잔류응력의 영향은 매우 작은 것으로 평가되었다.

  • PDF

Material Properties and Structural Characteristics on Flexure of Steel Fiber-Reinforced Ultra-High-Performance Concrete (강섬유 보강 초고성능 콘크리트의 재료특성 및 휨 거동 역학적 특성)

  • Kim, Kyoung-Chul;Yang, In-Hwan;Joh, Chang-Bin
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 2016
  • This paper concerns the flexural behavior of steel fiber-reinforced ultra-high-performance concrete (UHPC) beams with compressive strength of 150 MPa. It presents experimental research results of hybrid steel fiber-reinforced UHPC beams with steel fiber content of 1.5% by volume and steel reinforcement ratio of less than 0.02. This study aims at investigating of compressive and tensile behavior of UHPC to perform a reasonable prediction for flexural capacity of UHPC beams. Tensile behavior modeling was performed using load-crack mouth opening displacement relationship obtained from bending test. The experimental results show that steel fiber-reinforced UHPC is in favor of cracking resistance and ductility of beams. The ductility indices range from 1.6 to 3.0, which means high ductility of hybrid steel fiber-reinforced UHPC. Test results and numerical analysis results for the moment-curvature relationship are compared. Though the numerical analysis results for the bending capacity of the UHPC beam without rebar is larger than test result, the overall comparative results show that the bending capacity of steel fiber-reinforced UHPC beams with compressive strength of 150 MPa can be predicted by using the established method in this paper.

A Study on Microstructure and Mechanical Properties of TiC/Steel Composites Fabricated by Powder Metallurgy Process (분말야금공정으로 제조된 TiC/steel 금속복합재료의 미세조직 및 기계적 물성 연구)

  • Lee, Jihye;Cho, Seungchan;Kwon, Hansang;Lee, Sang-Kwan;Lee, Sang-Bok;Kim, Daeha;Kim, Junghwan
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.311-316
    • /
    • 2021
  • In this study, TiC/steel metal matrix composites were fabricated by powder metallurgy process using Fealloy powders with 3 wt.% Cr and 10 wt.% Cr, respectively, as matrix material. Subsequently, the composite samples were heat treated by the annealing and quenching-tempering(Q-T), respectively, to understand the effect of heat treatment on the mechanical properties of the composites. The correlation between microstructure and structural strength depending on the chromium content and the heat treatment conditions was studied through tensile, compressive, and transverse rupture test and microstructural analysis. In the case of TiC/steel composite containing 10 wt.% Cr, the tensile strength and transverse rupture strength at room temperature were significantly lowered by the influence of coarse chromium carbide formed at the TiC/steel interface. On the other hand, both TiC/steel composites containing 3 wt.% Cr and 10 wt.% Cr showed much higher compressive strength of about 4 GP after quenching-tempering compared to the annealed specimens regardless of the presence of the chromium carbide.

Improvement of strength and prevention of twist strain in sewer pipe using glass fiber and twist prevention band (유리 섬유와 뒤틀림 방지 밴드를 이용한 하수관거의 강도 및 뒤틀림 개선 방안 연구)

  • Hong, Seok In;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • Maintenance of sewer pipe process sewer pipe repairing process is necessary for deterioration of sewer pipe. In this research, analysis on performance (strength and twist strain) of eco-friendly and even expanded liner process using glass fiber and twist prevention band. As a results, tensile strength, bending strength and failure load is increased after the sewer pipe repairing process than advanced research results. And sewer pipe after the this process obtained advantage of prevention of twist strain and economic. After the this research, sewer pipe repairing process using glass fiber and twist prevention band could be suggest the eco-friendly and effective sewer pipe repairing process.

Evaluation of Properties of Polymer-Modified Mortar with CSA (CSA를 혼입한 폴리머 시멘트 모르타르의 성능평가)

  • Joo, Myung-Ki;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.35-44
    • /
    • 2015
  • Two main parameters were examined such as CSA content and polymer-binder ratio to find effects on the strength, water absorption, chloride ion penetration depth, carbonation depth, length change and chemical resistance of polymer-modified mortar with CSA and EVA polymer powder (EVAPP). As results, compressive, flexural, tensile, adhesive strengths, and length change of the polymer-modified mortar with CSA and EVAPP increases with increasing CSA content and polymer-binder ratio, although the water absorption, chloride ion penetration depth, and carbonation depth decrease with increasing polymer-binder ratio and CSA content, and also the chemical resistance decreases. Such strength and durability development is attributed to the high tensile strength of EVA polymer and the improved bond between cement hydrates and aggregates because of the addition of EVAPP and CSA.

A Comparison Study on Strength of Stainless Steel Tube and Steel Tube Stub-columns (스테인리스강관과 일반구조용강관 단주내력 비교에 관한 연구)

  • Jang, Ho Ju;Yu, Jea Hee;Yang, Young Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.561-570
    • /
    • 2003
  • This study evaluate the characteristics of stainless steel for the use of stainless steel tubes as structural members. The strength of stainless steel tube was compared with that of steel tube stub-columns through tensile experiment and compressed experiment. The selected experimental parameters were diameter (width)-thickness and section shape. The results of tests showed that stainless steel tubes could be predicted as superior to steel tubes in terms of tensile strength, yield ratio, elongation percentage, and absorption ability of energy. The yield strength of stainless steel tubes were found to be higher than the Korean Standards ($Fy=2.1tf/cm^2$) and the design strength of SIJ-ASD($Fy=2.4tf/cm^2$). It was also higher then the yield strength of steel tubes. The plastic deformation of stainless steel tubes was found to beto that of steel tubes.