• Title/Summary/Keyword: 압축성 간격재

Search Result 18, Processing Time 0.02 seconds

Resisting Behavior of Fully-Grouted Rock Bolts with Compressible Spacers (압축성 간격재를 설치한 전면접착식 볼트의 인발저항 거동)

  • Hwang, Yong-Sub;Lee, Sang-Duk
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.377-385
    • /
    • 2011
  • In order to prove the applicability of rock bolts with compressible spacers, laboratory model tests and large scale model tests were conducted. Laboratory model tests were performed in various distance of compressible spacers to determine the optimal distance of compressible spacers. The optimal distance of compressible spacers was found that is 1/4 of rock bolts unit length. Large scale model tests that the size was 0.6 m (diameter) ${\times}$ 4.45 m (length) were conducted. Test results showed that pull out resistance could be increased up to 15% larger than that of unused case by using compressible spacers.

Applicability Evaluation and Development of High Strength Spacer with Plastic Fiber and Slag Cement (플라스틱 섬유재와 슬래그 시멘트를 이용한 고강도 간격재의 개발 및 적용성 평가)

  • Kwon, Seung-Jun;Jo, Hong-Jun;Park, Sang-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.92-98
    • /
    • 2014
  • Spacer is a construction material for maintaining cover depth and steel installation, however several problems like staining, leakage, and cracking are currently issued due to performance degradation and unsatisfactory dimensional stability of spacer. Plastic composite is widely used for prevention of brittle failure in cement based material, which yields improvement of crack resistance and ductile failure. This study is for development and applicability evaluation of high strength spacer with slag cement for environmental load reduction and plastic composite like polypropylene fiber, nylon fiber, and glass fiber. For this work, unit weight of 4 different plastic fibers are evaluated through preliminary tests. Physical tests including compressive, flexural, and tensile strength and durability tests including absorption, permeability, length change, crack resistance, carbonation, and freezing and thawing are performed. Through various tests, optimum plastic fiber is selected and manufacturing system for high strength spacer with the selected fiber is developed. Dimensional stability of the developed spacer is evaluated through field applicability evaluation.

A Study on the Consolidation Analysis of Hydraulic Fills Applying Lateral Vacuum Consolidation Method (수평진공배수공법이 적용된 준설매립지반의 압밀 해석에 관한 연구)

  • Lee, Song;Kang, Myoung-Chan;Kim, Heung-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.209-220
    • /
    • 2001
  • 준설매립지반 표층강도증진을 위한 수평진공배수공법 적용시의 압밀현상 예측을 위한 연구를 수행하였다. 초연약지반에 수평배수재와 진공압을 이용하여 수평진공배수 공법을 적용할 경우, 배수재 부근에서 3차원적 배수특성과 넓은 범위의 유효응력의 변화, 지반의 압축성 및 투수성이 크게 변화하게 된다. 이를 위하여 3차원 배수특성과 다양한 경계조건, 부의 간극수압 발생을 통한 유효응력의 증가, 유효응력에 따른 압축성과 투수성의 비선형성을 포함할 수 있도록 기존의 3차원 압밀 지배방정식을 확장 유도하였고, 유효응력-간극비-투수계수의 관계를 누승형태의 함수로 표현하여 사용하였다. 해석기법의 타당성을 검증하기 위하여 실내에서 수행된 대형 토조실험 결과를 모델링하여 좋은 일치를 확인하였고, 이를 바탕으로 수평진공배수공법 적용시의 압밀효과에 대한 분석결과 드레인이 타설된 상부지반에서는 균등한 개량효과의 결과를, 하부의 미개량 지반에서는 자중압밀에 의한 압밀효과를 확인할 수 있었으며 배수재의 수평타설 간격에 따른 압밀효과 분석을 통하여 적정 배수재 설치간격의 범위를 확인하였다.

  • PDF

Nonlinear Analysis of Compressive Flange Based on Folded Plate Theory (Folded Plate Theory에 의한 압축플랜지의 비선형 해석)

  • Jung, Soo-Hyung;Shim, Jae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.169-178
    • /
    • 2008
  • Compressive flanges of steel box girder is designed based on the ultimate strength behavior of sub-panel which is enclosed with longitudinal stiffeners and transverse stiffeners on appropriate safety factor. However, it is rational that the ultimate strength is calculated considering the various factors such as number and stiffness of longitudinal stiffener, spacing of transverse stiffener, initial deformation and residual stress distribution. In this study, an analysis program based on Folded Plate theory is developed considering the geometric effects and the material nonlinearity. The analysis program is applicated to the steel box girder bridges which is really constructed in domestic.

Ultimate Behavior of Compression Flange Stiffened by Shear Stud on Double Composite Steel Box Girder (이중합성 강박스거더에서 전단연결재에 의해 보강된 압축플랜지의 극한거동에 관한 연구)

  • Lee, Doo Sung;Lee, Sung Chul;Suh, Suk Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.457-463
    • /
    • 2008
  • The longitudinal stiffener performs its role to increase the local buckling strength by making simple support upon compression flange. In the recent researches, it is investigated that compression flange with point supports on certain arrangement reveals the same strength with longitudinal stiffeners. From this results, it is predictable that shear stud could perform the role of longitudinal stiffener if shear stud embedded in concrete satisfies the requirement to point-support under yield stress of the compression flange. In this study, the researches were performed to investigate the optimally required arrangement space of longitudinal point-support for which the shear stud replacing the longitudinal stiffeners and simultaneously determine the required numbers and space of shear stud for completely composite behavior between compression bottom flange and bottom concrete on the double composite girder system.

The Compressive Strength of Thin-Walled Cold-Formed Steel Studs with Slits in the Web (복부에 슬릿이 있는 박판냉간성형형강 스터드의 압축강도)

  • Kwon, Young-Bong;Soe, Eung-Kyu;Lim, Duk-Man;Kim, Gap-Deuk;Kwon, In-Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.2
    • /
    • pp.189-197
    • /
    • 2012
  • The cold-formed steel stud, which has been used as a load-bearing member of wall panels for steel houses, poses a significant problem in insulation due to heat bridging of the web. Therefore, some additional thermal insulating materials are required. In order to solve this problem, the cold-formed steel thermal stud with slits in the web was developed. However, estimating the structural strength of thermal studs is very difficult because of the arrangement of perforations. In this paper, an analytical and experimental research on thermal studs is described. Three types of studs with different length, pitch and arrangement of slits were tested to failure. A simple design approach was proposed based on the test results. The proposed method adopted the direct strength method, based on the elastic local and distortional buckling stress of plain studs with equivalent thickness in the web instead of thermal studs. The predictions using the proposed method were compared with test results for verification and the adequacy of the proposed method was confirmed.

An Evaluation of Empirical Prediction Equation for Deformation Modulus of Rock Masses by Field Measurements (암반변형계수의 현장시험을 통한 경험적 추정식의 적정성 평가)

  • Chun Byung-Sik;Lee Yong-Jae;Ahn Kyung-Chul;Shin Jae-Keun;Jung Sang-Hoon
    • Tunnel and Underground Space
    • /
    • v.16 no.3 s.62
    • /
    • pp.251-258
    • /
    • 2006
  • In this paper, the applicability to the Korean rock condition of using the deformation moduli based on Rock Mass Rating (RMR) and Pressuremeter Test (PMT) is evaluated. The correlations among deformation moduli and various rock properties were also analyzed. It appears that the existing correlations using RMR overestimate the deformation moduli and wide variation was found between predicted moduli using these correlations and measured values. As for the correlations among the deformation moduli and various rock properties, Rock Quality Designation (RQD) and unconfined compressive strength (UCS) were found to correlate to deformation moduli reasonably well, but joint spacing and joint conditions appear to correlate poorly to RQD and UCS. Additionally, groundwater can not be correlated with the modulus values. While the depth has very little contribution to deformation modulus, it should be factored in the simple regression analyses with various rock mass properties, especially with the correlations made with UCS, RQD etc. With the deficiencies of these correlations, more in depth analysis techniques such as multivariate correlations may be to reliably estimate deformation modulus of rock mass.

Parameter Study of Buckling Behavior of Steel Built-up Column (강재 조립 기둥의 좌굴 거동에 대한 매개변수 해석)

  • Kim, Jinyong;Kim, Sung Bo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.79-87
    • /
    • 2011
  • The parameter study of buckling behavior of steel built-up column under compression force is presented in this study. The shear deformation effects due to the bending moment and shear forces are considered for the H-shaped main members along the entire built-up column and batten member connecting double H-shaped main members. The parametric study is performed according to the length of the built-up column, the distance of the H-shaped main members and the number and type of cover plate for battens, respectively. The applicability of AISC design specification of normal and high tension bolted built-up column is investigated. The buckling loads for built-up columns are compared with those obtained from the analytic solution developed in this study, AISC specification, and finite element method based on the beam and plate element, respectively.

Fundamental Study on the Strength and Heat Transferring Charcteristic of Cement Composite with Waste CNT (폐CNT를 혼입한 시멘트 복합체의 강도 및 열전달 특성에 대한 기초적 연구)

  • Koo, Hounchul;Kim, Woon-Hak;Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.66-73
    • /
    • 2022
  • The purpose of this study was to develop self-heating concrete by utilizing the conduction resistance of concrete in order to reduce the risk of occurrence of black ice in the concrete pavement in winter and to prevent damage caused by freez-thawing effect. For this purpose, it was attempted to evaluate the strength and temperature exothermic characteristics using powder and liquid waste CNTs and a waste cathode agent as a conduction promotion. It was analyzed that liquid waste CNT had an effective dispersion degree in the mortar and a small decrease in strength occurred. In addition, DC 24 V was supplied by applying steel mesh, copper foil and copper wire to the mortar as electrodes, and the temperature change characteristics according to the mixing ratio of spent CNTs, anodes and carbon fibers were evaluated. In addition, by evaluating the temperature characteristics according to the electrode spacing from the selected optimal mixture, it was confirmed that it had sufficient heating characteristics up to an electrode spacing of 100 mm up to AC 50 V.

Thermohydromechanical Stability Study on the Joint Characteristics and Depth Variations in the Region of an Underground Radwaste Repository (절리 발달 특성 및 심도 변화에 의한 방사성폐기물 처분장 주변영역에서의 열수리역학적 안정성 연구)

  • Kim, Jhinwung;Daeseok Bae;Park, Chongwon
    • Tunnel and Underground Space
    • /
    • v.13 no.2
    • /
    • pp.153-168
    • /
    • 2003
  • The objective of this present study is to understand long term(500 years) thermohydromechanical interaction behavior in the vicinity of a repository cavern on the joint location and repository depth variations. The model includes a saturated discontinuous granitic rock mass, PWR spent nuclear fuel in a disposal canister surrounded with compacted bentonite inside a deposition hole, and mixed bentonite backfilled in the rest of the space within a repository cavern. It is assumed that two joint sets exist within the model. Joint set 1 includes joints of 56$^{\circ}$ dip angle, spaced at 20 m, and joint set 2 is in the perpendicular direction to joint set 1 and includes joints of 34$^{\circ}$ dip angle, spaced at 20 m. In order to understand the behavior change on the joint location variations, 5 different models of 500m in depth are analyzed, and additional 3 different models of 1000 m in depth are analyzed to understand the effect of depth variation.