Abstract
The longitudinal stiffener performs its role to increase the local buckling strength by making simple support upon compression flange. In the recent researches, it is investigated that compression flange with point supports on certain arrangement reveals the same strength with longitudinal stiffeners. From this results, it is predictable that shear stud could perform the role of longitudinal stiffener if shear stud embedded in concrete satisfies the requirement to point-support under yield stress of the compression flange. In this study, the researches were performed to investigate the optimally required arrangement space of longitudinal point-support for which the shear stud replacing the longitudinal stiffeners and simultaneously determine the required numbers and space of shear stud for completely composite behavior between compression bottom flange and bottom concrete on the double composite girder system.
종방향 보강재는 압축플랜지를 단순지지함으로써 국부좌굴강도를 증가시키는 역할을 수행한다. 최근 연구에 의하면, 종방향으로 적절한 간격을 두고 점지지 되었을 경우 그 선을 따라서 단순 지지된 경우와 동일한 좌굴강도를 보이는 것으로 밝혀졌다. 이 같은 연구결과로부터, 하부콘크리트에 부착된 전단연결재가 압축플랜지의 좌굴시 점지지 조건을 만족할 수 있다면 전단연결재가 단순지지의 역할도 수행할 수 있을 것이라는 예측이 가능하다. 이와 같은 사실이 입증이 된다면, 강박스거더 제작비에서 매우 큰 부분을 차지하는 종방향보강재를 생략할 수 있기 때문에 보다 경제적인 설계가 가능해 질 것이다. 본 연구에서는 하부압축플랜지에 종방향보강재를 대체할 전단연결재의 종방향 배치 시 최소간격 결정과 동시에 하부 콘크리트와 합성거동을 하기 위해 소요되는 전단연결재 소요 개수와 간격을 결정하기 위한 연구를 수행하였다.