• Title/Summary/Keyword: 압력측정시스템

Search Result 508, Processing Time 0.028 seconds

A Comparative Study of Frequency Response Models for Pressure Transmission System (압력전달시스템을 위한 주파수응답모델들의 비교 연구)

  • Kim, Hyeonjun;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.2
    • /
    • pp.83-93
    • /
    • 2020
  • Dynamic pressure transducer needs to be flush-mounted on hardware due to frequency response characteristics of pressure transmission system. However, it is sometimes necessary to be mounted in recessed configuration due to insufficient space for sensor installation and for protection of sensor from thermal damage. Dynamic response characteristics should be considered due to distortion of original dynamic pressure signal in the pressure transmission system. In this study, small perturbation model and 2nd order reduced model were compared with experiments and a guideline for selecting a frequency response model was suggested.

New calibration apparatus for a precise barometer (초정밀 기압계 교정을 위한 새로운 압력계 교정장치 개발)

  • 우삼용;이용재;최인묵;김부식;최종운
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.3
    • /
    • pp.157-161
    • /
    • 2003
  • Nowadays there are increasing demands for more accurate measurement of atmospheric pressure according to the development of environmental industries. One of the most important pressure gauges for satisfying these demands is a quartz resonance barometer. In order to calibrate such an accurate barometer, laser/ultrasonic mercury manometers have been used. However, complexity and cost of mercury manometers made it out of use gradually. As a substitute, a gas-operated pressure balance is used for calibration of precise barometers. In such a case, commercially available pressure balances cannot be entirely suitable because consequent exposure of the piston, cylinder and masses to the atmosphere causes the problem of contamination. In this paper a device for changing the masses in situ without breaking the vacuum is described. This device made it possible to add or remove weights in the absolute mode, thereby greatly reducing the time between observations. At the same time, we investigated the characteristics of a commercial precise barometer using this new apparatus.

An Implementation of Spirometry System Based Differential Pressure Method (차동 압력 방식을 이용한 호흡측정 시스템 구현)

  • 김요한;신창민;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.440-447
    • /
    • 2002
  • This paper considerated about exact flow volume calculation method from factors having an influence on measurement and introduced in anesthesia ventilator realized spirometry system. System used differential pressure sensing method with factors, that is temperature, pressure, gas density, humidity and mucus etc. System optimized for low power system for mobile system. System composed analog interface part, signal processing part, display part. Analog interface part have differential pressure flow sensor and defferential pressure sensor. Signal processing part have AVR processor for low power system display part use serial port (RS232, SPT). so it display at pc monitor or send to anesthesia ventilator. System is stable by linearizing 2th characteristics of flow-differential pressure, auto correction of sensor. Noise reduced by algorithm with analog filter and digital processing. Small, light, low power system is good at mobile system and applied to patient in emergency or mobile. and, System is useful at anesthesia ventilator by using flow sensor.

  • PDF

Implementation of The Drug Infuser with Active Pressure Control Method (능동적 압력조절이 가능한 약물주입기 구현)

  • Cho, Seong-Beom;Noh, Yun-Hong;Moon, Chang-Su;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.817-818
    • /
    • 2012
  • 본 연구에서는 치과에서 마취 시 환자들의 고통을 최소화 하기위하여 무통마취를 위한 치과용 약물주입기를 구현하였다. 약물의 주입 시 통증을 최소화하기 위해서 온도를 $36{\pm}2^{\circ}C$ 범위로 제어하여 체온과 유사한 온도로 유지하였다. 이를 위하여 필름히터 방식을 이용한 치과범용국소약물(36mg, 2% 리도카인) 앰플 가열부를 설계하였다. 또한 약물이 주입되는 양을 능동적으로 제어하기 위하여 약물주입 환부의 환자별 흡수 속도 차이에 차등 주입을 위한 압력 측정 시스템을 구현하였다. 필름 형태의 압력 센서를 통하여 전달 압력을 측정하였으며 측정된 압력을 바탕으로 능동적으로 모터의 동작을 제어함으로써 약물주입시 환자의 고통을 최소화 할 수 있도록 구현하고자 하였다.

  • PDF

Mass balance equation을 이용한 대형 진공용기의 진공도 계산과 측정

  • Kim, Se-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.356-356
    • /
    • 2011
  • 챔버 내부의 압력은 gauge가 달려 있는 몇몇 지점에만 국한되어 읽을 수 있었기 때문에 gauge를 이용한 압력 측정을 통해 보다 상세한 진공도를 구하기란 쉽지 않다. 챔버 내부의 압력은 빔 운전에 적합한 초고진공을 유지하여야 하고, 균일하여야 하므로 신뢰 할 수 있는 방법으로 진공도를 정확히 계산해 볼 필요가 있다. 그리하여 압력에 영향을 미치는 여러 가지 진공 시스템 내부의 요소인 Outgassing, 배기속도, 컨덕턴스, 압력 등을 mass balance equation을 이용해 수식화 하여 정리한다. 이 수식을 가지고 FEA(Finite element analysis)프로그래밍을 이용해 진공도를 계산한다. FEA 프로그래밍에 쓰이는 프로그램은 Matlab, excel을 이용하였다. 이 프로그래밍 결과에 따라 Pressure Profile을 작성 하고, 시간이 변함에 따라 진공도가 어떻게 변하는지 실제로 계산하여 time constant를 구한다. 이 값들을 챔버를 가지고 측정한 데이터와 비교하여본다.

  • PDF

A Development Of The Portable Spirometry System Of Pressure Method Using Static Pressure In Pitot Tube (개구관에서의 정체압을 이용한 차동 압력 방식의 휴대형 호흡측정 시스템 개발)

  • 이종수;신창민;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.479-486
    • /
    • 2001
  • Spirometer is a medical equipment which diagnoses respiratory function by measuring 9as volume across Patient's lunes through airway. Because a little overdose of anesthesia medicine can take away Patient's life in the ventilator for a surgical operation. an exact measurement of respiring volume is very important. This Paper Presented an exact flow volume calculation method from factors having an influence on measurement and introduced a spirometry system for an anesthesia ventilato. This system, using differential Pressure sensor measured flow by mutual relation with Pressure. temperature. gas density and linearization from the 2nd order characteristics of differential pressure with flow.

  • PDF

Development of Pressure Monitoring System and Pressure Changes during Kimchi Fermentation (김치발효 중 가스압력 변화와 압력측정시스템의 개발)

  • Lee, Young-Jin;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.686-689
    • /
    • 1990
  • For the monitoring of kimchi fermentation states, pressure detecting sensor and monitoring device were designed and fabricated. The system was consisted of an air tight fermenting tube(31.5 ml), strain gauge type pressure sensor and signal processing device built with operational amplifier and A/D converter, and interfaced to personal computer. Chiness cabbage kimchi was fermented in the plastic container($150{\times}220{\times}160mm$) at $25^{\circ}C\;and\;30^{\circ}C$. The fermentation was monitored with fermenting tubes containing kimchi. The pressure based kimchi fermentation curve was constructed and showed a typical kimchi curing curve having 2 stepwise pressure increasing pattern.

  • PDF

Effects on Injection Time. Filling Pressure, and holding Time on Injection-molded Lens Pats (렌즈 성형품에 대한 사출시간, 충진 압력, 그리고 보강시간의 영향)

  • 송영현
    • The Korean Journal of Rheology
    • /
    • v.4 no.2
    • /
    • pp.116-126
    • /
    • 1992
  • 본 연구에서는 형내압 파형제어 시스템, 초고속, 사출성형, 그리고 금형진공 시스템 등을 갖춘 사출 성형기를 이용하여 정밀 구면렌즈를 성형하기 위한 실험을 수행하였다. 이 러한 목적을 위해 성형공정 변수인 사출시간 충전압력 그리고 보압시간이 성형품에 미치는 영향을 중량과 곡률반경 구면 정밀도 그리고 구면오차의 간접무늬를 측정하여 연구하였다. 그결과로서 성형품의 중량(칫수)과 곡률반경에 지대한 영향력을 행사하는 변수는 충전압력 이며 사출시간과 보압시간은 곡률반경과는 무관해 보이고 중량의 증가에는 기여하지만 공정 사이클 시간을 증가시키는 문제가 지적된다. 구면정밀도 측정실험 결과 길지도 짧지도 않는 15∼20초 사이의 보압시간 4초이내의 빠른 사출시간 그리고 860kg/cm2 이상의 높은 충전압 력에서 우수한 결과를 보여주었다, 마지막으로 구면의 형상에 대한 간접무늬 측정결과는 성 형공정을 이해하는데 강력한 도구가 됨을 발견하였다.

  • PDF

Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers (접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향)

  • Choi, Ik-Hwang;Lee, Jae-Ik;Kwon, Goo-Do;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.358-363
    • /
    • 2008
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Thus, in this study, we investigate the effects of such experimental system dependent factors in the measurement of ultrasonic nonlinear parameter by using contact PZT transducer. Experimental results showed that the effect of system dependent nonlinearity is reduced when the contact pressure and transducer input voltage are sufficiently large. These results will be very useful to find out the proper experiment condition to measure rather accurate nonlinear parameter.

진공펌프 배기속도 측정 방식에 따른 구조적 오차 및 보정

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.169-169
    • /
    • 2011
  • 진공펌프의 성능을 나타내는 여러 파라미터가 있지만 가장 중요한 성능지표는 역시 배기속도라고 할 수 있다. 배기속도는 물리적으로 체적유량(volume flow rate, L/s 또는 m3/hr) 즉 단위시간당 펌프 흡기구에 들어오는 기체의 체적을 가리킨다. 펌프 흡기구 단면을 지나가는 체적을 직접 측정하는 것은 거의 불가능하므로 진공 전문가들은 흡기구로 들어가는 기체 유량(flow rate, mbar${\cdot}$L/s 또는 Pa${\cdot}$m3/s)과 흡기구 압력(mbar 또는 Pa)을 측정한 후 유량을 압력으로 나누어 주는 방식으로 배기속도를 측정한다. 유량은 표면 기체 방출을 고려하더라도 실용적인 측면에서 보면 위치에 상관없이 불변하는 값으로 볼 수 있어서 유량을 어떻게 정밀하게 잴 것인가 하는 방법만 있으면 편리한 위치에서 측정하면 된다. 반면에 압력을 정밀하게 측정하는 방식은 확립되어 있지만 막상 어디서 측정하는 것이 옳은가 하는 것은 의외로 쉽지 않다. 펌프의 배기속도를 측정하는 상황을 몇 가지로 가정해 보면, 규격에 입각한 표준용기에 달아 정식으로 재는 것, 게이지가 부착된 마구리판을 달고 간이로 재는 것, 펌프가 사용되고 있는 시스템 현장에서 재는 것이 있을 수 있고 펌프가 달려 있는 상태도 직접 용기에 달거나, 도관 또는 어댑터 및 밸브를 통해 달리는 경우가 있다. 앞에서 펌프 배기속도 계산 시 사용하는 흡기구 압력이란 엄밀히 말하면 흡기구를 바라보는 방향으로 가해지는 압력을 말하는데 이는 진공 게이지를 펌프 흡기구 면에서 상류를 향하도록 놓을 때 얻을 수 있는 값으로 막상 실행하는 것은 어렵다. 표준용기의 구조는 진공 게이지를 특정 위치에 달 때 마치 흡기구 면에 놓인 게이지처럼 흡기구 압력을 정확하게 측정할 수 있도록 고안된 것이지만 때에 따라서는 여러 변형된 측정 방식을 사용할 수밖에 없는 상황이 만들어지므로 어떤 보정을 거치면 올바른 배기속도 값을 구할 수 있는지 살펴볼 필요가 있다.

  • PDF