• Title/Summary/Keyword: 안전 점검

Search Result 1,060, Processing Time 0.033 seconds

Monitoring of Restaurant Beef Labeling System (음식점 식육 원산지 표시 모니터링)

  • Hong, Jin;Leem, Dong-Gil;Kim, Mi-Gyeong;Park, Kyoung-Sik;Yoon, Tae-Hyung;No, Ki-Mi;Jeong, Ja-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.2
    • /
    • pp.162-169
    • /
    • 2010
  • The compulsory beef labelling system has launched from January 1st 2007 by the amended Food Hygiene Law, we were checked the actual conditions of beef origin with a nationwide scale by the Hanwoo differentiation specific test method which was developed by Korea FDA using 90 SNP biomarkers. The test method is useful tool to differentiate the beef origin carrying out the mission of KFDA's annual food safety management guidance. Also we have technically transferred the Hanwoo differentiation specific test method to other institutes as well regional KFDA and established the training program as a regular course in Korea Human Resource Development Institute for Health and Welfare. The beef used in this study were collected according to the 2009 Food safety guidance in roast beef restaurants where business site area greater than 100 $m^2$. Total 216 samples were consisted of 48 samples of the Seoul area and 168 of the region. The monitoring result from restaurants in all the region of Korea showed that 3 of 216 Hanwoo-labelled beefs were found out as a non-Hanwoo (1.3%). This results are gradually deceasing trend compared with 34.0% in 2005, 30.1% in 2006, 3.2% in 2007 and 5.14% in 2008. From these data, the Hanwoo differentiation specific test method on the settlement of the compulsory beef labelling system has an important role. As a outcome of this project, we might be considered the early settlement of the compulsory beef labelling system, technically transferred to other institutes and the establishment of regular training program of the test method.

Study on the Safety of Firefly Luciferase in Human as a Transient Reporter Gene of Oncolytic Virotherapy (항암 바이러스 치료제의 보고유전자로써 반딧불이 루시퍼레이즈의 인체 내 안전성에 대한 연구)

  • Hong, Young Mi;Yoon, Woong Hee;Lee, You Ra;Kim, Soo Ji;Ngabire, Daniel;Narayanasamy, Badrinath;Ornella, Mefotse Saha Cyrelle;Kim, Myunghee;Cho, Euna;Lee, Bora;Hwang, Tae-Ho
    • Journal of Life Science
    • /
    • v.31 no.11
    • /
    • pp.1028-1036
    • /
    • 2021
  • Firefly luciferase (FLuc) can function as an efficient marker in the gene and viral therapies. Nonetheless, its clinical translation has been unaccomplished with the concerns on its exogenous nature and the similarity with human fatty acyl-CoA synthetase. In this study, we aimed to show safety of FLuc by conducting a set of preclinical experiments and a human use. Initially, FLuc permeability across the plasma membrane was investigated by delivering the FLuc-carrying viral vector, OTS-412, or the FLuc recombinant protein. After in vitro infection of OTS-412 into different cancer cell lines, FLuc activity was detected only in the cell lysates, but not in culture media. In addition, recombinant FLuc protein further showed the impermeability against the plasma membrane. Similar result was also observed in the in vivo experiment. After being injected into the VX2 tumor-bearing rabbit, the FLuc exclusively resided within the tumor tissue without being detected in the blood plasma or other organs. Human cancer cell lines originated from various organs were lysed and treated to the FLuc, and none of the human substrates was reactive against the FLuc. As a final step, FLuc recombinant protein was intravenously injected into a human. The luciferase was degraded with the half-life of 20 to 30 minutes in blood, and was untraceable from 1.5 hr after the injection. In addition, the blood plasma was nonresponsive against the fatty acids. Hematological analysis was also comparable between the pre- and post-injection. Altogether, our study collectively demonstrates the safety of the firefly luciferase.

A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.

Parents' Opinions on Foodservices in Daycare Centers of Korea's Compensation and Welfare Service Institute (근로복지공단 보육시설의 급식 운영현황과 학부모대상 품질 만족도)

  • Kim, Ji Hyeon;Lee, Young Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.1
    • /
    • pp.102-113
    • /
    • 2013
  • The purpose of this study was to examine parental perceptions on the importance, performance level, and satisfaction with foodservice quality at daycare centers in the Compensation and Welfare Service institute. The questionnaire was developed to measure thirty-two attributes of foodservice operations are administered to 598 parents and 23 foodservice supervisors from June 22, 2009 to July 10, 2009. The parents placed a high importance on the need for foodservices, earning 4.70 points out of 5 points. Their perceptions of foodservice quality menu, foodservice ingredients and effects, facilities, sanitation, and service scored even higher than performance. The overall satisfaction level for foodservice compared to performance was 4.33 and 4.03 points out of 5 points, respectively. Multiple regression analysis indicated that 98.6% of the variance in parents' overall satisfaction scores was explained by six dimensions.

An Evaluation for Structural Performance of Suspension Bridge by using the Natural Frequency of Hanger Member (행거의 고유진동수를 이용한 현수교의 구조적 성능 평가)

  • Wu, Sang Ik;Kim, Kyoung Nam;Lee, Seong Haeng;Jung, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.285-293
    • /
    • 2004
  • As a special infrastructure, it is important that the suspension bridges which were designed by using the cable are carefully maintained and safely inspected after their construction, more than what is done in other cases of bridge structures. However, the structural analysis for their design and maintenance has considered only the simplified geometric shape of the structure. Particularly, it is not easy to make the modeling analyze the bridge structure including detailed steel deck plates. In this paper, we evaluated the structural behaviors and performances of the completed earth-anchored suspension bridge that was in a completed state through both the tension of hanger member and their computational analysis. We considered the frame system and the detailed steel deck plates that were especially added into the modeling to take more precision analysis about it. We also applied hanger tensions converted by the natural frequency and the natural frequency of the bridge when in normal vibration. Results of the vehicle loading test were used in the analysis. We compared the results by using our modeling with the result of the loading test and the hanger tension. Our prediction on the behavior of the structure emulates the behavior of the real structure. In applying the data measured by the typhoon "Maemi" which arrived in-land last year, we confirmed our analysis model for the possibility of applying effectively into the preliminary design and maintenance plan.

Fidelity in Core Principles of Ayres Sensory Integration$^{(R)}$ Intervention: In Clinical Practice (Ayres의 감각통합중재 중심원리에 따른 치료사의 치료수행도 조사)

  • Hong, Eun-Kyoung;Kim, Kyeong-Mi;Chang, Moon-Young
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.9 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • Purpose : In this study, we tried to know that how the occupational therapists applied the core principles of Ayres's sensory integration(ASI) intervention for clients by using the method of self-assessment. Methods : The study period was from May 2010 to June 2010. The subjects were therapists who use a sensory integration intervention. We letted them to do self-assessment about degree of performing the treatment according to the core principles of ASI by using a questionnaire. Total 66 questionnaires were collected. SPSS for Windows version 15.0 was statistically analyzed. Results : There wasn't anybody without considering the 10 core principles of ASI interventions for children. Therapist's answer(more than 90%) was sometimes, often, always except for the guide self-organization in the 10 core principles of ASI intervention. On the basis of total average score of raw score of 10 core principles of ASI intervention, provide sensory opportunities, provide just-right challenges, collaborate on activity choice, maximize child's success, ensure physical safety, and foster therapeutic alliance showed more than 50 points(T value). The guide self-organization, support optimal arousal, create play context, and arrange room to engage child showed less than 50 points T value. Conclusion : The most effective interventions for sensory integration is the treatment based on the core principles of ASI intervention. According to core principle of ASI intervention, checking the quality of care and increasing the quality of care is needed through performing self-assessment.

  • PDF

Construction of Faster R-CNN Deep Learning Model for Surface Damage Detection of Blade Systems (블레이드의 표면 결함 검출을 위한 Faster R-CNN 딥러닝 모델 구축)

  • Jang, Jiwon;An, Hyojoon;Lee, Jong-Han;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.80-86
    • /
    • 2019
  • As computer performance improves, research using deep learning are being actively carried out in various fields. Recently, deep learning technology has been applying to the safety evaluation for structures. In particular, the internal blades of a turbine structure requires experienced experts and considerable time to detect surface damages because of the difficulty of separation of the blades from the structure and the dark environmental condition. This study proposes a Faster R-CNN deep learning model that can detect surface damages on the internal blades, which is one of the primary elements of the turbine structure. The deep learning model was trained using image data with dent and punch damages. The image data was also expanded using image filtering and image data generator techniques. As a result, the deep learning model showed 96.1% accuracy, 95.3% recall, and 96% precision. The value of the recall means that the proposed deep learning model could not detect the blade damages for 4.7%. The performance of the proposed damage detection system can be further improved by collecting and extending damage images in various environments, and finally it can be applicable for turbine engine maintenance.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

The Analysis of the Process Elements and the Characteristics of Biologists' and Gifted Students' Designing Experiment Activities (생물학자와 과학영재의 실험설계활동에서 나타나는 과정요소 및 특성 분석)

  • Yang, Il-Ho;Ryu, Seol-Jin;Lim, Sung-Man
    • Journal of Science Education
    • /
    • v.33 no.2
    • /
    • pp.271-289
    • /
    • 2009
  • The purpose of the research was to analyze the characteristics and the process elements which appeared to the process of designing experiment for biologists and gifted students in science. Four biologists and thirty-two gifted students were participated in this study. The findings indicated that (a) the researcher figured out the process elements could constructed in fifteen elements such as confirming questions, arrange materials, consideration for experimental subjects, searching variables, eliminating variables, selecting variables, planning operation of variables, planning control environmental variables, planning control biological variables, planning the methods of observation and assessment, planning the methods of collecting data, planning the interpretation of data, planning the repetition of experiments, planning the repetition of assessment, safety regulations as well. The biologists concentrated in the particular process elements related with variables, since the science-gifted students concerned the performance whole process elements themselves without deeper consideration, (b) the characteristics of biologists and science-gifted students in the process of designing experiment were as follows; 1) biologists and students showed the process elements which include the domain specific process skills as well, 2) biologists accurately conducted the designing experiments processes with repetition of specific process, since students designed experiments conventionally, and 3) biologists possessed the domain specific skills and know-how about their experiments, but students did not. The results show that the programs of designing experiment activity should be constructed with the process elements which were concentrated by biologists, should provide feedbacks to design experiment more accurately, and should be developed with concern of the process skills and know-hows of biologists.

  • PDF

Nondestructive Evaluation of Remanent Life of Turbine Rotor Steel by Measuring Reversible Magnetic Permeability (가역투자율 측정에 의한 터빈로터강의 비파괴적 잔여수명 평가)

  • Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Yong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.315-321
    • /
    • 2003
  • The integrity of the turbine rotors can be assessed by measuring the material properties at service temperature. In order to evaluate the remanent life of turbine rotor steel nondestructively, a measurement system of reversible magnetic permeability using an alternating perturbing magnetic field was constructed. We present a new non-destructive method to evaluate the remanent life of 1Cr-1Mo-0.25V steel using the value of reversible magnetic permeability. This method is based on the existence of reversible magnetic permeability in the differential magnetization around the coercive field strength. We measured the first harmonics voltage induced in a coil using a lock-in amplifier tuned to an exciting frequency. The Results of reversible magnetic Permeability and Wickers hardness on the aged samples show that the peak interval of reversible magnetic permeability (PIRMP) and Vickers hardness decreases as aging time increases. A softening curve is obtained from the correlation between Vickers hardness and the PIRMP. This curve can be used as a non-destructive method to evaluate the remanent life of turbine rotor steel.