• Title/Summary/Keyword: 안전해석

Search Result 4,389, Processing Time 0.039 seconds

Numerical Study on the Leakage Safety of O-rings for a LPG Cylinder Valve (LPG 용기 밸브용 O-링의 누설안전성에 관한 해석적 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.2 s.35
    • /
    • pp.37-42
    • /
    • 2007
  • This paper presents the leakage safety of two O-rings, which are located at the rectangular groove between a valve body and a valve stem. The leakage safety analysis of 0-ring seals has been computed as functions of a compression set and a liquefied petroleum gas pressure of a LPG cylinder using a FEM program, MARC. The FEM computed results indicate that the loads from the filling pressure of $8kg/cm^2$ to the upper limit of the safety valve, $24.8kg/cm^2$ work safely according to the pressure vessel code. But two O-rings should consider the aging effects for an increased safety of the o-ring.

  • PDF

A Comparative Study of Safe Factor of Slope according to Analysis Methods (해석 방법에 따른 비탈면 최소안전율 비교 연구)

  • Ryu, Hang Taek;Jang, Jeong Wook;Chung, Youn In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.5
    • /
    • pp.207-216
    • /
    • 2018
  • This research compared and analyzed safety ratio of slope with Talren97 and SoilWorks based on limit equilibrium analysis and Midas GTS based on finite element analysis. For the analysis variables, there are slope height, berm condition, soil parameter, groundwater level, slope inclination. All of slope stability analysis were performed by dividing into dry season and rainy season. As the result of the analysis of Talren97 and SoilWorks based on same theory, safety ratio of slope shows same value, so there was no difference between the programs. In comparison with limit equilibrium analysis, the result of finite element analysis showed somewhat high ratio of safety and it was higher by about 2.4% averagely. The difference between the result of limit equilibrium analysis and that of finite element analysis is in the range which can ignored in practical work.

고리 1호기 가압열충격 해석을 위란 계통 열수력 해석 연구

  • 김용수;김재학;홍순준;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.751-756
    • /
    • 1998
  • 고리 1호기 원전 수명 연장을 위한 가압열충격(Pressurized Thermal Shock : PTS) 해석은 확률론적 안전성 평가 방법에 따라 수행된다. 본 연구는 가압열충격 상세 해석 연구의 일환으로 가압열충격 해석을 위한 계통해석시 사용되는 최적 평가(Best Estimate) 방법과 기존의 PCT(Peak Cladding Temperature) 관점의 해석에 사용되는 결정론적 안전성 평가 방법간의 해석 방법론 차이에 의한 열수력 거동의 상이점을 평가하기 위함이다. 이를 위해 1998년 설치 예정인 고리 1호기 교체 증기발생기(Replacement Steam Generator ; RSG) 안전성 분석 보고서$^{[1]}$ 의 주증기관 파단사고 해석 결과와 동일한 파단 크기 및 운전 출력에 대해 최적 평가 방법론에 따라 해석된 본 연구의 해석 결과를 비교, 평가하였다. 해석 결과 전출력 소형 주증기관 파단 사고에서는 터빈 유량 모델링 및 반응도 계수, 고온 영출력 대형 파단 사고에서는 가압기 모델, 반응도 계수 및 정지여유도가 해석 방법론에 따른 열수력 거동의 차이에 영향이 큰 것으로 평가되었다

  • PDF

가압경수로 안전주입계통 최적화를 위한 SBLOCA 영향 고찰

  • 이남호;허재영;배규환;이상종;황순택
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.519-524
    • /
    • 1996
  • 울진 3,4호기 안전주입계통의 용량 변화가 가상적인 소형냉각재상실사고 거동에 미치는 민감도 해석을 수행하여 이를 System 80 설계발전소의 CESSAR-F 와 비교함으로써 후속호기 계통설계 및 사고해석을 위한 안전주입계통의 최적화에 활용코자 하였다. 본 논문에서 해석은 USNRC가 승인한 ABB-CE 평가 모델을 적용하여 수행하였으며, 이의 결과 소형 파단 사고시 안전주입탱크의 용량 및 고압 안전주입유량을 울진 3,4호기의 60% 까지 줄였을 때에도 경수로용 비상노심냉각계통 허용 기준$^{(1)}$ 을 만족함을 확인하였다.

  • PDF

A Study on Seismic Performance Evaluation of Road Tunnel according to Seismic Analysis Conditions (내진해석 조건에 따른 도로터널 내진성능평가에 관한 연구)

  • Choi, Byoung-Il;Kim, Chan-Hee;Noh, Eun-Cheol;Ha, Myung-Ho;Park, Si-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.127-134
    • /
    • 2021
  • When constructing a tunnel on a stable ground, stress is changed in the ground during excavation stage and installation of ground support materials. In the standards for safety evaluation of structures in use, it is suggested to perform numerical analysis reflecting the excavation stage. But method of seismic performance evaluation was not presented. Therefore, in this study, numerical analysis was performed with different analysis methods, and the results were compared and analyzed. As a result of the numerical analysis, seismic wave applied in the horizontal direction were no difference depending on the analysis methods. However, there was a big difference in the result according to the evaluation methods of tunnel member forces. When reviewing with the strength design method, the structure performance could be not satisfied depending on the existence or nonexistence of reinforcing bars. Based on these research results, it is suggested that the interpretation method should be clearly presented and reflected in the relevant standards.

비선형 균열배관 해석 방법을 이용한 배관 안전성 평가

  • 김태순;박치용;김진원;박재학
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.169-174
    • /
    • 2001
  • 원자력발전소 배관계통에 존재하는 균열을 해석하는 방법으로, 이제까지는 균열을 고려하지 않은 상태에서 지진하중을 고려한 탄성 배관해석을 수행하여, 배관에 작용하는 하중을 구한 후, 다음 단계에서 파괴해석 방법으로 균열을 가정한 탄소성 균열해석을 수행하는 2단계의 해석을 통해 균열안정성을 평가해 왔다. 이러한 방법은 전체 배관의 거동과 배관 내에 존재하는 균열의 거동을 서로 독립적인 것으로 고려하고 있으며 재료물성치로는 설계값을 사용하는 등의 보수적인 가정들을 포함하고 있어 배관에 작용하는 하중 또는 응력을 과도하게 계산하는 결과를 초래하고 있다 특히, 지진하중과 같은 반복적인 외부 동적하중이 작용하는 경우, 배관에 국부적인 소성변형이 발생함에도 이를 단지 탄성거동으로 간주하게 되는 것이다. 이러한 몇몇 보수적 가정들을 포함하고 있는 기존의 해석방법은 지나친 보수성을 가질 뿐만 아니라, 균열에 의한 실제 배관의 파단하중과 계산에 의한 파단하중의 비교로서 배관의 안전여유도를 예측하는 방법으로는 적절하지 못하다.(중략)

  • PDF

직교이방성 판 내에서의 균열전파 해석

  • 김만원;박재학
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.251-256
    • /
    • 2000
  • 이방성 재료에서 균열의 성장을 예측하는 것은 실제 구조물의 안전성을 정확하게 해석하기 위한 중요한 문제이다. 이방성 재료 내에서의 균열의 거동은 등방성 재료의 경우와는 다르기 때문에 이방성 재료 내의 균열 해석 문제가 중요한 관심을 끌게 되었다. 비등방성 재료에 대한 지금까지의 연구는 대부분 직선균열의 해석, 직선균열의 초기 전파 각도에 대한 해석에 대하여 이루어져 왔고 곡선 균열에 대한 연구[1-4]는 많이 이루어지지 않았다.(중략)

  • PDF

Analysis of Loss of Condenser Vacuum Accident using a Conservative Approach with a Best-Estimate Code (최적코드를 이용한 복수기진공상실 사고의 보수적 해석)

  • Jeong, Hae-Yong
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.175-182
    • /
    • 2015
  • A methodology to determine the most conservative initial condition based on random sampling of operation parameters is established, in which a best-estimate computer code is adopted to minimize the conservatism in code models. To validate the applicability of the suggested method, safety evaluation for a transient of loss of condenser vacuum in a pressurized water reactor is performed. One-hundred different initial conditions are generated by MOSAIQUE program automatically and the peak pressure for the most conservative case is determined from transient analyses. The safety margin obtained with the new approach is almost equivalent to the values determined with the existing methodologies. It is found that the time and human resources required for the safety evaluation could be reduced with the suggested approach.

Flow Safety Assessment by CFD Analysis in One-touch Insertion Type Pipe Joint for Refrigerant (CFD 해석을 이용한 냉매용 원터치 삽입식 파이프 조인트의 안전성 평가)

  • Kim Eun-Yonung;Park Dong-sam;Kim, Hong-Yong
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.303-304
    • /
    • 2022
  • 파이프는 기계, 전자, 전기, 플랜트 등 많은 산업 분야에서 응용기기로 널리 사용되고 있으며, 소방, 화학 등 안전 관련 분야에서도 널리 사용되고 있다. 제품의 다양화에 따라 배관 분야에서도 기술의 중요성이 높아지고 있다. 특히 기존 동관을 스테인리스강으로 변경하는 경우 구조해석이나 유동 해석을 통해 안전성과 유동특성을 평가할 필요가 있다. 자체 개발한 일체형 인서트형 커넥터인 6.35 소켓 모델의 유동 안전성은 CFD 해석을 이용하여 유동유발진동(FIV)평가 과정의 4단계를 통해 진행하였다. 배관계 벽면에 작용하는 압력변동의 진폭은 3,780Pa이하의 수준으로 형성되며, 이는 냉매 배관의 운전압력이나 설계응력과 비교했을 때 매우 작은 수준의 압력으로, 난류에 의한 진동이 배관의 구조안전성에 미치는 영향은 미미한 수준인 것으로 나타났다.

  • PDF