• Title/Summary/Keyword: 안전주입

Search Result 382, Processing Time 0.036 seconds

Secure RSA with CRT Protected Against Fault Attacks without using Checking Procedure (비교연산을 사용하지 않는 오류주입 공격에 안전한 CRT 기반의 RSA)

  • Kim, Sung-Kyoung;Kim, Tae-Hyun;Han, Dong-Guk;Park, Young-Ho;Hong, Seok-Hie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.4
    • /
    • pp.17-25
    • /
    • 2008
  • Because Chinese Remainder Theorem based RSA (RSA CRT) offers a faster version of modular exponentiation than ordinary repeated squaring, it is promoting with standard. Unfortunately there are major security issues associated with RSA CRT, since Bellcore announced a fault-based cryptanalysis against RSA CRT in 1996. In 1997, Shamir developed a countermeasure using error free immune checking procedure. And soon it became known that the this checking procedure can not effect as the countermeasures. Recently Yen proposed two hardware fault immune protocols for RSA CRT, and this two protocols do not assume the existence of checking procedure. However, in FDTC 2006, the method of attack against the Yen's two protocols was introduced. In this paper, the main purpose is to present a countermeasure against the method of attack from FDTC 2006 for CRT-RSA. The proposed countermeasure use a characteristic bit operation and dose not consider an additional operation.

한강하저 터널에서의 지반상태에 따른 보강공법 -그라우팅을 중심으로-

  • 박남서
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 1995.03a
    • /
    • pp.27-40
    • /
    • 1995
  • 한강하저의 지질은 수많은 대ㆍ소 단층들로 인해 심하게 교란되어 있어 지질상황의 변화가 매우 심하며, 터널을 굴착함에 있어 지하수의 유입을 차단하는 것이 안전시공을 위한 필수 과제로 직면한다. 본 고에서는 기 시공실적을 바탕으로 암반상태에 따른 차수그라우딩의 패턴을 비교ㆍ검토하였다. 본 구간에서는 암반상태에 따라 5가지 패턴이 적용되었으며, 경암 암반일 경우는 상부반단면만을 주입범위(주입범위 : 3.5m, 28공)로 하고 암반의 전단강도증진을 위해 강관보강을 시행하였다. 연암 암반 내지 파쇄대가 부분적으로 협재된 경우는 상부반단면만을 주입하되 주입범위 및 그라우팅 공수를 늘리는 방식(주입범위 : 5∼7, 42∼56공)으로 보강하였다. 풍화암 암반의 경우는 전단면을 주입범위로 하여 그라우팅 공수를 늘림(주입범위 : 7m, 81공)으로서 차수효과를 증진시켰다. 또한 본 공사구간 중 가장 난제였던 연약지반대(잔류토 내지 풍화토) 85m 구간은 자문회의 등을 거쳐 주입범위, 주입길이 및 주입공수, bulk head 구간을 늘려 시공하고, 굴착하면서 차수효과를 확인하는 방식을 취하였다.

  • PDF

Harmonic Reduction of Electric Propulsion System by Current Injection (전류주입에 의한 전기추진시스템의 고조파 저감)

  • Kim, Jong-Su;Han, Won-Hui;Seo, Dong-Hoan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.4
    • /
    • pp.360-364
    • /
    • 2012
  • AC to DC converter that consists of relatively simple diode rectifier devices has been widely used in the field of the electric propulsion system. Also, since this rectifier includes large harmonics in the input current, a variety of researches have been developed to reduce the harmonics. The proposed method of this paper is to reduce the harmonics included in the input current of rectifiers and propulsion motor by injecting the output current of diode rectifier into the input of them. In addition, the proposed method ensures electrical safety through the respective isolation of the injection current, the source, and the loads using the Wye-Delta insulating transformer applied in current injection device that is installed in the input circuit of rectifiers and propulsion motor. The proposed method is simulated by applying to the electric propulsion ship that is currently operating. We confirm the validity of the proposed method compared with conventional power conversion system.

원자로 정지 관련 동적보상기의 응답시간 평가

  • 주운표;황희수;우숭웅;김건중
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.309-314
    • /
    • 1996
  • 가압 경수로형 원전 안전정지/ 안전 주입 변수와 관련된 계기는 관련 기술 기준에 따라 정기 보수시 교정이 이루어지면, 정지 신호를 모의 주입하여 물리량 검출기로 부터 원자로 정지집계 권선의 풀림시간까지의 총 응답 시간이 사고해석시 가정된 계통의 응답 지연시간이내에 들어 있는 지를 확인한다. 이 정지 신호에 응답하는 동적 보상기의 특성과 관련하여 설계과정에서 삽입된 근사화 오차에 대한 정략적인 평가가 이미 알려진 바 있고, 시간 응답 측정시 삽입되는 지연 요소로 인한 오차도 이에 포함시켜 분석한 바 있어 실제 교정시 정밀도 향상을 위하여 활용하고 있다. 이 논문을 통하여 원자로 정지계통의 응답시간 측정시 노 냉각수 평균 온도 변화율 동적 보상 미분-지연 카드에 모의입력으로 스텝신호를 주입할 경우, 이를 과도하게 큰 신호로 인식하여 매우 짧은 시간(1초 이내)에 응답되고, 스텝신호대신 1%P.U./초로 평균온도 변화율만을 주입할 경우, 보다 늦게 응답됨을 밝혔다. 따라서 모의 시험 방범에 있어서 입력 선택을 적합하게 하여야만 계통의 건전성을 응답시간으로 확인한 수 있는 데, 이에 적합한 모의 입력 방법을 제안하였다.

  • PDF

Secure CRT-RSA against SPA and FA (SPA와 FA에 안전한 CRT를 사용하는 RSA 알고리즘)

  • Kim, Sung-Kyoung;Kim, Hee-Seok;Kim, Tae-Hyun;Han, Dong-Guk;Hong, Seok-Hui;Ryoo, Jeong-Choon;Lim, Jong-in
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.02a
    • /
    • pp.89-93
    • /
    • 2008
  • 본 논문에서는 단순전력 분석(SPA)과 오류주입공격(FA)에 안전한 중국인의 나머지 정리를 이용한 RSA 암호 시스템(CRT-RSA)에 대하여 논한다. CRT-RSA를 이용한 서명 알고리즘은 스마트카드와 같은 내장형 장치(embedded device)에서 널리 사용된다. 하지만 이러한 장치들은 전력분석 공격과 오류주입 공격에 취약하다. 2005년 Giraud가 처음으로 단순전력분석과 오류주입공격에 모두 안전한 대응 방법을 제안하였다. 본 논문에서는 Giraud의 대응 방법에 대한 다른 공격방법을 소개하고, 제시한 공격 방법에도 안전한 대응 방법을 제안한다. 본 논문에서 제안하는 대응 방법은 세 개의 메모리와 덧셈과 뺄셈연산을 추가적으로 요구한다. 추가적으로 요구되는 연산량은 모듈러 지수승 연산에 필요한 연산량에 비교하면 크게 고려하지 않아도 될 연산량이다. 그러므로 본 논문에서 제안하는 대응 방법은 내장형 장치와 같은 환경에서 안전하고 효율적으로 이용될 수 있다.

  • PDF

월성원자력발전소 비상노심냉각계통의 수격현상 해석

  • 이중섭;오광석;김선철;오종필;김도현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.67-72
    • /
    • 1996
  • 수격현상(Waterhammer)으로 인한 과도압력하중은 월성원자력발전소 비상노심냉각계통 (Emergency Core Cooling System : ECCS) 설계의 주요 고려사항이다. 비상노심냉각계통은 특수안전계통으로서 냉각재상실사고(Loss of Coolant Accident : LOCA)후 일차열수송계통을 다시 채워주고 핵연료 손상을 막기위해 노심으로부터 잔열 및 붕괴열을 제거한다. 일차열수송계통으로의 비상냉각수 주입은 고압주입, 중압주입, 저압주입 3 단계로 주입된다. 과도압력이 발생될 것으로 예상되는 고압주입과 중압주입에 대한 6가지 사례들이 ECCS의 배관과 지지대 설계를 위해 고려되었다. 모든 사례에 대한 비상노심냉각계통의 과도압력 현상은 PTRAN 코드에 의해 해석 되었고 해석된 최고과도압력은 설계압력보다 작음을 알게 되었다. 모든 사례의 최고압력과 최고차압은 비상노심냉각계통 배관 및 지지대 설계를 위한 응력해석 자료로서 사용될 것이다.

  • PDF