• Title/Summary/Keyword: 악취관리

Search Result 139, Processing Time 0.03 seconds

Physicochemical Characteristics and Estimation of H2S Emission Rate from Municipal Solid Waste at the Environmental Facilities in Busan City (부산지역 환경기초시설에서 발생하는 폐기물의 물리, 화학적 특성 규명 및 황화수소 발생량 예측에 관한 연구)

  • Lee, Taeyoon;Kim, Doyong;Kim, Jaejin;Lee, Junki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.13-20
    • /
    • 2009
  • There have been increasing interests in the odor generation problems as concerns about the quality of life has been increased recently. Especially, approximately 67% of the odor complaints from environmental facilities are those from sewage treatment facilities and food waste treatment facilities. Moreover, sewage ocean dumping will be prohibited from 2012 by the international and domestic ocean laws, and thus, demand for alternative management plans is increasing. Therefore, it was first selected 5 sewage treatment facilities and 5 food waste treatment facilities where the amounts of waste are relatively immense in Busan, and collect their sludge samples. Then it was investigated the samples' physical and chemical characteristics through proximate analysis, elemental analysis, XRF analysis, and calorific value analysis. Finally, estimate the $H_2S$ emission rates were estimated in order to apply the results as the basic data for providing the fundamental solution for the oder complaints. As a result, the concentration of $H_2S$ in sewage sludge and in food waste treatment facility were 57.3 mg/kg and 19.7 mg/kg in average, respectively. Finally, the units of $H_2S$ in wastes stored in total 10 waste treatment facilities was estimated 16,017,910.0 mg/d.

  • PDF

Investigation on the Management of Livestock Wastes and VOCs Concentration of Farms in Daejeon Area (대전광역시 양축농가의 축분뇨 관리 실태 및 VOCs 농도 조사)

  • Lee, Bong-Duk;Lee, Soo-Kee;Oh, Hong-Rok;Heo, Jung-Min;Jung, Kie-Chul;Kim, Sung-Bok
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • This study was carried out to investigate the style of livestock house, concentration of malodorous substances of livestock feces and livestock houses in Daejeon area. Among the livestock houses investigated, as most of cow pens(94.5%) have sawdust or chaff on the bottom, there was no leakage of feces out of pen. Most pig pens adopted slury style, but some of them currently use buffering material on the bottom. It is thought that there will be no possible contamination leakage. When it comes to hen house, all the broiler house use litters on the bottom and all the layer house use scrapper. It is also thought that there will be no possible contamination leakage. 3 out of 12 deer pens used buffering material on the bottom, 10 places were maintained in a traditional method, and 7 places left possibility of contamination leakage considering whether the roof was installed or not. The contents of ammonia, amine and volatile fatty acid in fresh feces were lower compared to rotten feces, but the concentration of sulfur-containing matter - hydrogen sulfide, methylmercapthan and ethylmercapthan were higher compared to rotten feces. In the case of malodorous ingredient in livestock houses, only small amount of ammonia and hydrogen sulfide were detected in pig pen and hen house, and other ingredients were not detectable. And those who are engaged in animal husbandry reacted negatively to the use of feed additives for decreasing malodor. In conclusion, it is not worrisome that contamination can be leaked out of animal raising facilities. But if we take into consideration that the point of investigation time is wintry season, there should be more considerate attitude. And feed additives for decreasing malodor need establishing criteria in the manufacturing process.

  • PDF

열정! 건설현장을 찾아서 - 철저한 안전관리로 쾌적한 안전도시 춘천 조성, 코오롱글로벌 춘천시 하수관거정비 임대형민자사업현장

  • Yeon, Seul-Gi
    • The Safety technology
    • /
    • no.182
    • /
    • pp.16-18
    • /
    • 2013
  • 강원도 춘천시에 최근 새로운 변화의 바람이 불고 있다. 우 오수관로를 신설하고 재정비함으로써 하수관거의 기능을 개선하고 하수처리장의 운영효율을 증대시키는 공사가 대대적으로 펼쳐지고 있는 것이다. 2015년 1월, 이 사업이 완료되면 춘천시는 방류 수역 수질개선으로 악취가 저감되고 쾌적한 환경이 조성되는 등 지역주민의 생활환경이 크게 개선되는 효과를 얻을 수 있다. 더불어 효율적인 하수관 유지보수체계도 구축할 수 있게 된다. 사실상 더욱 살기 좋은 춘천시의 등장이 임박한 것이다. 이런 행복한 변화를 만들어내고 있는 주인공은 바로 '코오롱글로벌'이다. '코오롱글로벌 춘천시 하수관거정비 임대형민자사업현장'은 춘천시를 전국 제일의 행복도시로 만들겠다는 신념으로 시공에 임하고 있다. 때문에 공사의 품질을 좌우하는 '안전'에 만전을 기하고 있다. 철저한 안전관리를 통해 춘천을 최고의 주거환경을 갖춘 도시로 변화시키고 있는 이곳 현장을 찾아가 봤다.

  • PDF

A Study on the Management of Landscape for Rural Sprawling Development (농촌 난개발요소 경관관리방안에 대한 연구 - 진안군을 사례로 -)

  • Yang, Hee Seung
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.5
    • /
    • pp.305-316
    • /
    • 2021
  • Sprawling development factors in rural areas are adversely affecting the rural landscape and furtherthreatening the safety of localresidents. Through the case of Jinan-gun, the government intends to promote sustainable preservation and improvement of beautiful rural landscapes by studying landscape management plans for sprawling development factors and suggesting landscape and environmental improvement plans. In order to analyze the problems of the target site, opinions were collected through analysis of the surrounding environment and resident interviews. As a result of the analysis, in case of Jinan-gun, odorreduction management in harmful facilities was the most urgent, and this study planned the relocation of harmful facilities and eco-friendly smart livestock districts.

A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities (폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.69-84
    • /
    • 2023
  • Despite the continuous installation and regular inspection of waste treatment facilities, complaints about excessive incineration and illegal dumping stench continue to occur at on-site treatment facilities. In addition, field surveys were conducted on the waste treatment facilities currently in operation (6 type) to understand the waste treatment process for each field, to grasp the main operating factors applied to the inspection. In addition, we calculated the material·energy balance for each main process and confirmed the proper operation of the waste disposal facility. As a result of the site survey, in the case of heat treatment facilities such as incineration, cement kilns, and incineration heat recovery facilities, the main factors are maintenance of the temperature of the incinerator required for incineration and treatment of the generated air pollutants, and in the case of landfill facilities Retaining wall stability, closed landfill leachate and emission control emerged as major factors. In the case of sterilization and crushing facilities, the most important factor is whether or not sterilization is possible (apobacterium inspection).In the case of food distribution waste treatment facilities, retention time and odor control during fermentation (digestion, decomposed) are major factors. Calculation results of material balance and energy resin for each waste treatment facility In the case of incineration facilities, it was confirmed that the amount of flooring materials generated is about 14 % and the amount of scattering materials is about 3 % of the amount of waste input, and that the facility is being operated properly. In addition, among foodwaste facilities, in the case of an anaerobic digestion facility, the amount of biogas generated relative to the amount of inflow is about 17 %, and the biogas conversion efficiency is about 81 %, in the case of composting facility, about 11 % composting of the inflow waste was produced, and it was comfirmend that all were properly operated. As a result, in order to improve the inspection method for waste treatment facilities, it is necessary not only to accumulate quantitative standards for detailed inspection methods, but also to collect operational data for one year at the time of regular inspections of each facility, Grasping the flow and judging whether or not the treatment facility is properly operated. It is then determined that the operation and management efficiency of the treatment facility will increase.

Application case of odor management applied direct olfactory method in Iksan (익산지역에서 직접관능법에 의한 악취관리 사례 연구)

  • Kim, Hwa-Ok;Park, Hui-Geun;Shin, Dae-Yewn;Kang, Gong-Unn
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.2
    • /
    • pp.17-30
    • /
    • 2009
  • In Iksan city, there have been a lot of complaints caused by offensive odor from residents living near the public environmental infrastructures and the Iksan industrial complex. To solve these problems, it is important to know the present condition of odor pollution level in these areas, the emission characteristics of malodorous gases in temporal and spatial variations in addition to meteorological components, and the facilities of major sources emitting malodorous compounds. The objectives of this study is to make the odor monitoring network for 20 people who lived and worked in areas where the environmental infrastructures and the Iksan industrial complex are located and their neighboring areas for six months from June 1st to October 31st in 2008 in Iksan and to monitor the temporal and regional frequency and characteristics of odor intensity using direct olfactory methods. As a result of odor monitoring, the highest frequency of sensed odor per month and 20 people for six months was found to be 107 in July, followed by 84 in September, 80 in August, 54 in June, 38 in October, respectively. Odor intensity trend showed a regional trend in the decreasing order of Dongsan-dong, Busong-dong, and Palbong-dong. Odor was widely perceived from night through next morning and considered as the sense of excreta, chemicals, sewage, compost, waste, etc. When high odor intensity was sensed, there were constant meteorological characteristics: relative humidity was 80~90%, wind speed was less than 0.5~1 m/sec, and main wind directions were from the east, the southeast, and the south.

A review of analytical method for volatile fatty acids as designated offensive odorants in Korea (악취성 유기지방산 성분의 분석기술)

  • Ahn, Ji-Won;Kim, Yong-Hyun;Kim, Ki-Hyun;Song, Hee-Nam
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.91-101
    • /
    • 2012
  • A list of volatile fatty acids (VFA) including propionic acid, butyric acid, isovaleric acid, valeric acid, etc. is well known for offensive odorants. The analysis of odorant VFA is a highly delicate task due to high reactivity and unstable recovery rate. At present, analytical methods of VFA are recommended to include alkali impregnation filter method and alkali absorption method by the malodor prevention law of the Korea Ministry of Environment (KMOE). In this review, a survey has been made to explore various approaches available for the analysis of VFA to include both official methods of the KMOE and others. In light of the unreliability of those established analytical methods, it is highly desirable to develop some substituting methods for VFA. Among such options, one may consider such option as sorbent tube (ST) sampling and cryogenic trapping-thermal desorption technique. Moreover, procedures used for standard preparation, sampling steps, and instrumental detection stage are also evaluated. Application of container sampling (like Tedlar bag) is however not recommendable due to significant (sorptive) loss in sampling and in storage stage. In the detection stage, the use of GC/MS is recommendable to replace GC/FID due to the presence of diverse interfering substances. Thus, it is essential to properly establish the basic quality assurance (QA) for VFA analysis in air.

Development of VOCs Treatment Technology using High Efficiency Hybrid System with Multi-Scrone (멀티 선회류식 세정장치를 이용한 고효율 하이브리드 VOCs 습식처리 SYSTEM 개발)

  • Lim, Seong-Il;Kim, Nor-Jung;Kim, Sun-Mi;Lee, Seong-Hun;Kim, Sun-Uk;Chang, Won-Seok;Park, Dae-Won;Kim, Lae-Hyun;Kim, Jae-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.491-498
    • /
    • 2009
  • We studied to develop high-efficiency removal system of odor and VOCs(Volatile Organic Compounds) from environmental infrastructure facilities and oil refineries, painting facilities and so on. It can replace RTO and RCO. We tried an removal experiment for VOCs (toluene, xylene, benzene, MEK(methyl ethyl ketone), ethanol, formalin etc. and odor compounds (hydrogen sulfide, etc.). In process, as pre-treatment we used the scrubber with vortex flow (Multi-scrone) to remove the hydrophilic VOCs and as post-treatment, used fibrous bio-filter to remove the hydrophobic VOCs. This hybrid system remove with high efficiency both the hydrophilic VOCs and hydrophobic VOCs. And we tried to make this system to be compact. In experiment using Multi-scrone, contact time is 2~3 seconds and absorption scrubbing water is diaphragm-type electrolysis water. hydrophilic VOCs like ethanol and relatively hydrophilic odor compounds like hydrogen sulfide is excellent, these substances has been removed almost completely, respectively 95~99%, 93~97%. And for MEK, formalin also Showed a high removal efficiency, respectively 78~90%, 72~85%. But in experiment using Multi-scrone, the hydrophobic VOCs like BTX showed a low removal efficiency, respectively 16~22%, 12~18%, 8~16%. In hydrophobic VOCs, toluene removal experiment using fibrous bio-filter, early efficiency was low but after 10days, adaptation period showed high efficiency 85~95%. but in the mixed phase, toluene and MEK efficiency reduced 5~10%. this show microorganism treat first MEK easy to remove. The removal efficiency for MEK using the fibrous biofilter was stable, 80~92%. This hybrid system is also high economical efficiency for RTO. This system reduce more than 50% the cost of equipment and maintenance. As a result, we expect this technology is in the limelight as high efficiency treatment of VOCs in mid-low price.

A study on inspection methods for waste treatment facilities(II): Derivation of problems and improvement direction in inspection methods (폐기물처리시설의 세부검사방법 마련연구(II): 세부검사방법 문제점도출 및 개선방향 설정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.85-100
    • /
    • 2023
  • In this study, in order to improve the installation periodical inspection method of waste treatment facilities, we conducted on-site surveys of waste treatment facilities classified into six fields, grasped the problems of inspection methods, and made improvements accordingly. And revised the inspection method for waste treatment facilities. As a result, in the field of incineration and incineration heat recovery, inspection methods such as total temperature measurement and one-year TMS data comparison using a thermal imaging camera were established. And for the safety of the inspected person, it was applied so that the waste can be replaced with a document without opening it. In the case of landfill facilities, the details regarding the use of video information processing equipment and the management of facilities covering the upper part of the landfill facility are presented in the law, but the items that do not have a inspection methods were applied to the inspection method. In the case of Food Waste Treatment Facility, inspection methods were put in place to ensure compliance with standards for foul-smelling fish in odor control, a major cause of complaints. As a result, 10 out of 18 improvement proposals were reflected in the incineration and sterilization grinding, cement kiln, and incineration heat recovery facilities, and 11 out of 12 improvement proposals were reflected in the landfill facility. In the case of food distribution waste treatment facilities, 10 out of 12 improvement proposals were reflected, and a total of 31 inspection methods were improved.

Development of a Prototype for Access Control in ICT Monitoring System Using Plasma (플라즈마를 이용한 ICT 모니터링 축사 출입관리 시제품 개발)

  • Kim, Jin-Ha;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1221-1226
    • /
    • 2019
  • The importance of livestock production of agriculture in Korea is very large. Investments in sanitation facilities and environmental factors such as animal health and odor have been relatively crude, and over the past few years animal disease has emerged as the leading cause of domestic livestock farmers' income stability. There is a need for an access control system that can be purchased and installed by small and medium-sized farmers who are suffering from pollutants and small farmers who can not afford to install costly sterilization on an economical basis. In this paper, based on the plasma access control system proposed previously, we developed an ICT surveillance access control prototype system that can ensure safety and security through access control and integrated control system that introduces a sterilization system using plasma required by farmers affected by pollutants.