• Title/Summary/Keyword: 심장팬텀

Search Result 26, Processing Time 0.027 seconds

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

An IMADF Algorithm for Adaptive Noise Cancelation of Biomedical Signal (생체신호의 적응잡음제거를 위한 비적적응필터 알고리즘)

  • Yoon, Dal-Hwan;Lin, Chi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.1
    • /
    • pp.59-67
    • /
    • 2009
  • In this paper, we have proposed the structure of the IMADF(improved modified multiplication-free adaptive filter) to cancel the adaptive noise in biomedical signals. The IMADF structure use the one-step predicted filter in the multiplication-free adaptive digital filter(MADF) structure using the DPCM and Sign algorithm. And then we use the heart phantom model based on the magnetocardiographic (MCG) to test the biomedical signals and analyze the signal of it. Their functions of the heart phantom occur from the multidipole current source. This can play role the same in the real function of the human heart to study it. In the experimental results, the IMADF algorithm has reduced the computational complexity by use of only the addition operation without a multiplier. Also, under the condition of identical stationary-state error, it could obtain the stabled convergence characteristics that the IMADF algorithm is almost same as the sign algorithm, but is better than the MADF algorithm. Here, this algorithm has effective characteristics when the correlation of the input signal is highly.

Convergence Comparison of Metal Artifact Reduction Rate for Pacemaker Insertion of CT Imaging Phantoms in the Raw Data with MAR Algorithm (심박조율기 삽입 팬텀의 CT영상 원시데이터에 금속인공물감소 알고리즘 적용 시 금속인공물 감소율의 융합적 비교)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2017
  • In the analyzed cardiac CT algorithm applied when comparing the MAR self-made metal artifact reduction in pacemaker inserted phantom degree. Result of comparing the energy value by CT showed a decrease in the CT value in the case of BKG 40 KeV in WSA maximum decreased to 663.2% in the case of 140 KeV BHA were increased a maximum of 56.2%. In addition, the maximum was decreased by approximately 145% based on a 70 KeV artifacts in CT value comparison by type WSA, BHA was to increase up to approximately 46.38%. MAR Algorithm is believed to provide a more quality cardiac CT image if the energy changes, or have the effect that by type and irrespective of reduced metal artifacts occurrence of artifacts applied to the pacemaker when tracking a heart CT scan after inserting MAR algorithm.

A study on the usefulness of a fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT of severely injured patient (중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구)

  • Seo, Sun-Youl;Han, Man-Seok;Kim, Chang-Gyu;Jeon, Min-Cheol;Kim, Yong-Kyun;Kim, Gab-Jung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.211-216
    • /
    • 2017
  • The purpose of this study is to evaluate the usefulness of a newly fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT(computed tomography) of severely injured patient. Radiation dose was measured in the heart, both axillary and thyroid areas using newly designed cloak shield and existing shield with head phantom and human phantom under the same conditions as brain vascular CT scan. The newly designed cloak shield was measured higher for radiation shielding rate than the existing shields, 61.9 % for heart, 46.2 % for left axillary, 69.8 % for right axillary and 71.1 % for thyroid gland, respectively. a newly developed fusion model of cloak shields are useful for reducing radiation exposure. It is expected to make a significant contribution to reduction of radiation exposure.

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF

Implementation of Nuclear Medicine Dynamic Cardiac Phantom for Clinical Application (임상적용을 위한 핵의학 동적 심장팬텀의 구현)

  • Lee, Joo-Young;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.53-59
    • /
    • 2019
  • In the field of nuclear medicine, the various static phantoms of international standards are used to assess the performance of the nuclear medicine equipment. However, we only reproduced a fixed situation in spite of the movement of the cardiac, and the demands for dynamic situations have been continuously raised. More research is necessary to address these challenges. This study used flexible materials to design the dynamic cardiac phantom, taking into account the various clinical situations. It also intended to reproduce the images through dynamic cardiac flow to confirm the usefulness of the proposed technique. The frame of dynamic cardiac phantom was produced based on the international standard phantom. A nuclear medicine dynamic cardiac phantom was produced rubber material and silicone implemented by 3D printing technique to reproduce endocardium and epicardium movement. Therefore we compared and evaluated the image of a cardiac phantom made of rubber material and a cardiac phantom made of silicone material by 3D printing technique. According to the results of this study, the analysis of the Summed Rest Score(SRS) showed abnormalities in the image of a cardiac phantom made of rubber material at 10, 20, and 30 stroke rates, but the image of a cardiac phantom made of silicone material by 3D printing technique showed normal levels. And the analysis of the Total Perfusion Deficit(TPD) showed that TPD in the image of a cardiac phantom made of rubber material was higher than that of the image of a cardiac phantom made of silicone material by 3D printing technique at 10, 20, and 30 stroke rates. The potential for clinical application of the proposed method was confirmed in the dynamic cardiac phantom implemented with 3D printing technique. It is believed that the objective information secures the reliability of inspection equipment and it contributes to improve the diagnostic value of nuclear medicine.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Assessment of Entrance Surface Dose and Image Distortion in Accordance with Abdominal Obesity in the Chest Radiography (흉부 X-선 검사에서 복부비만에 따른 입사표면선량과 영상 왜곡도 평가)

  • Kim, Boo Soon;Park, Jeong Kyu;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.473-478
    • /
    • 2015
  • Abdominal obesity is one of the most influential index to predict of insulin resistance syndrome/metabolic syndrome in social demographic characteristics. It is matter of fact that radiation dose are increasing with development of medical treatment and device. In this study, we estimated distortion between reference image and entrance surface dose when take a chest radiography forward chest phantom assumed abdominal obesity. When angle of chest phantom incline $5^{\circ}$ forward, thoracic transverse and longitudinal diameter increase 1.22% and 0.44% each. Also cardiac transverse diameter increase 1.01% and cardio-throracic ratio (CTR) decrease 0.27% in the same situation of incline to $5^{\circ}$ forward. Thoracic transverse diameter shows the largest increase, and CTR was decreased. But entrance surface dose to phantom increase significantly 6.12% when angle of chest phantom incline $5^{\circ}$ forward. In conclusion, we have to pay attention to accurate positioning, to prevent a distortion of image through incline, and make patients not to expose to additional radiation.

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF