Performance Evaluation of Water Vapour Adsorption/Desorption Property for a Building Material by Mock up Test (실물시험을 통한 흡방습 건축자재의 성능평가)

  • Kim, Hea Jeong;Song, Kyoo Dong;Lee, Yun Gyu
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.53-58
    • /
    • 2009
  • There are increasing developments and uses of functional building materials are recently developed and introduced to the test method for the materials. Especially, moisture problem has a major role are also being established in indoor air quality problems. The purpose of this study is to evaluate the water vapour adsorption/desorption property of a ceiling material. The variation of the temperature and moisture were measured with the application materials by mock up test based on JIS 1470-1. The result shows that water vapour adsorption/desorption property of ceiling material is appeared in changes of moisture adsorption and desorption in comparison with that of a general ceiling material. Therefore, in case of decreasing and increasing in humidity, these materials can be used as an finishing material to sustain comfort condition.

Hoop Ring Test Method to Evaluate the Fiber Material Properties of Composite Motor Case (Hoop ring 시험방법을 이용한 복합재연소관의 섬유방향 물성 평가)

  • Hwang, Tae-Kyung;Park, Jae-Byum;Kim, Hyung-Kun;Lee, Sang-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.429-432
    • /
    • 2009
  • The deformation and burst pressure of composite motor case highly depends on fiber material properties. Therefore, measuring exact fiber material properties is a priority item to develop a advanced composite motor case. However, the fiber material properties in composite motor case is very sensitive on the various processing variables (equipment, operator and environmental condition etc..)and size effect, so the fiber material properties can't be measured exactly from the existing specimen test method. This paper suggests a newly developed test method, hoop ring test, that is capable of pressure testing with ring specimens extracted from real composite motor case. The results of hoop ring test showed excellent agreement with measured fiber material properties from hydro-burst test with full scale composite motor cases.

  • PDF

The Structural Characteristics of Non-slip Device in Connecting Method Between Steel Pipe Pile and Footing (미끌림 방지턱을 이용한 강관말뚝 머리 결합부의 구조특성에 관한 실험적 연구)

  • 박영호;김낙영
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.227-243
    • /
    • 2003
  • To find the structural characteristics of non-slip device in connecting method B between steel pipe pile and concrete footing, compression and uplift test was performed for full sized specimens not having non-slip device, those having non-slip device with two curved steel plate bars welded inside the steel pipe pile(standard method), and those having non-slip device with serveral curved steel plate bars bolted inside the steel pipe pile(new method). As a result, specimens not having non-slip device had chemical debonding failure at 15.6tonf of peak uplift load and 27.57tonf of peak compression load. And the standard method and the new method showed about 8.9 times of peak uplift load and 6.2 times of peak compression load higher than specimens not having non-slip device. The load transfers of lower non-slip devices of the standard method and the new method were similar in behavior, while the higher non-slip device of the new method showed higher ratio of load transfer than that of the standard method. And these two methods had nearly the same composite action and structural capacity caused by non-slip devices.

원지점 차넣기 모타 적용 잠입노즐 기초 기술 개발

  • 노태호;황종선;조인현
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.32-32
    • /
    • 2000
  • 잠입노즐은 로케트 추진기관의 길이 및 중량을 감소시켜 체계설계의 관점에서 볼 때 많은 이점을 제공한다. 본 연구에서는 3단형 과학로케트 원지점 차넣기 모타(apogee kick motor)에 적용하기위한 잠입노즐의 기초기술 개발에 주안점을 두었다. 고고도에서 저속으로 회전하며 비행하는 원지점 차넣기 모타를 제작하기위해서 체계 요구성능에 의해 예상된 실물형의 50% 크기에 해당하는 축소형 잠입노즐을 제작하였다. 잠입노즐은 잠입부의 내외부가 고온의 추진제 연소가스에 노출된 상태에서 노즐 내부 압력 외에 연소실압에 의한 외부압력이 작용하므로 이를 고려한 열 및 구조설계가 중요하다. 본 연구에서는 노즐 수렴부와 목부에 일체형 그라파이트 소재를 적용하고 확장부 내열재 및 잠입부 배면내열재에 탄소/페놀 복합재를 노즐 내열재로 사용하였다. 그리고 이들의 구조적 지지를 위해 스틸구조물을 적용하였다. 적용된 스틸구조물에는 K형 열전쌍을 이용해 내열재와 구조물 온도를 측정할 수 있는 관통구멍 및 나사부를 구조물 외변에 가공하였다. 열전쌍은 노즐 목직경의 2, 4배 되는 확장부 내열재 단면위치의 2mm와 4mm 깊이와 구조물 내면 및 외면의 4개소에 열전쌍을 부착하여 지상연소시험시 노즐 내열재와 구조물의 온도분포를 관찰한다. 그리고 노즐 조립시 확장부 내열재와 구조물에 각 각 반원형 홈을 내어 여분의 접착제가 원형 홈에 밀려들어가 경화되어 노즐 기밀유지와 체결력을 향상시킬 수 있는 원형공간 접착제 충전 공법을 적용하여 실제모타에 대한 적용가능성을 지상연소시험을 통해 확인한다.

  • PDF

Design, Manufacture and Test of Subscale Solid Rocket Motor with Pulse Separation Device (펄스분리장치를 적용한 소형 추진기관의 설계, 제작 및 시험평가)

  • Ryu, Jung-Hun;Lee, Won-Bok;Suh, Hyuk;Kim, Won-Hoon;Oh, Jong-Yun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.133-137
    • /
    • 2010
  • A dual pulse solid rocket motor has several advantages compared to the single one. The range and the terminal velocity of the guided missile can be remarkably increased by the application of the pulse separation device(PSD) to the solid rocket motor which resulted in appropriate thrust distribution. In this study, the subscale dual pulse solid rocket motor with the bulkhead type PSD was designed, manufactured, and fire-tested. The bursting pressure, thermal characteristics, and the structural safety of the PSD were obtained by the tests and the results will be applied to the design of full-scale dual pulse rocket motor.

  • PDF

Bursting Performance Analysis of a Pulse Separation Device for a Rocket Motor (추진기관 적용 펄스분리장치의 파열특성 분석)

  • Lee, Dong-Won;Lee, Won-Bok;Kim, In-Sik;Kim, Won-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.245-248
    • /
    • 2011
  • A multi pulse rocket motor(MPRM) has several advantages compared to the single one. The range and the terminal velocity of the guided missile can be remarkably increased by the application of the pulse separation device(PSD) to the solid rocket motor which resulted in appropriate thrust distribution. In this study, the full scale heavy type dual pulse rocket motor with the bulkhead type PSD was designed, manufactured, and fire-tested. The bursting time and pressure of PSD were analyzed by the pressure, thrust and vibration results of static fire tests. As a result, the design requirement was verified that bursting pressure is lower than 30% of 2nd pulse operating pressure.

  • PDF

Performance Assessment for Rockfall Protection Systems II: Performance Assessment (낙석방지울타리의 성능평가 II: 성능평가)

  • Kim, Kee Dong;Ko, Man Gi;Kim, Dal Sung;Han, Ki Jang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.49-61
    • /
    • 2015
  • This is the second of two companion papers that describe the performance assessment for flexible rockfall protection systems. Described in a companion paper is the criteria to assess the performance of flexible rockfall protection systems. In this study the performance assessment of domestic rockfall protection fences was implemented using the criteria suggested in the companion paper. It was investigated that the rockfall protection fences for express highways performed well to resist the rockfall energy of 50kJ and the deformed rockfall protection fences right after impacting would not obstruct the vehicle traffic. However, to dissipate the rockfall energy of 50kJ with the level of European standards constantly, the spacing of wireropes was adjusted to be 200mm up to the 8th wirerope from the bottom and spacing-maintainers should be extended to the 8th wirerope. It was figured out that the rockfall protection fences for general highways were required to install spacing-maintainers as those for express highways because they, which did not have spacing-maintenance members, were very prone to the penetration of rockfall even for the very small rockfall impact energies.

A Comparison of Concrete Median Barriers in terms of Safety Performance using Computer Simulation (컴퓨터 모의층돌시험을 통한 콘크리트 중앙분리대 방호울타리 형식별 성능비교 연구)

  • 정봉조;장명순
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.1
    • /
    • pp.115-125
    • /
    • 2003
  • The concrete median barriers are the most popular safety appurtenance that can be installed on narrow medians and are effective in keeping uncontrolled vehicles from crossing into opposing lanes of traffic. It is necessary to install and maintain median barriers because it is very difficult to reserve enough room required for medians in KOREA. Also, concrete median barriers are accepted as the actual alternatives for median barriers, mostly because they require almost no maintenance even after serious collisions. Typical concrete median barriers are 810mm high and have 596mm high glare screens on top of them. However we have experienced a number of "climb" and "roll-over" accidents of heavy vehicles and most of all, there have been some serious accidents caused by the part of broken glare screens. So the improvement study of concrete median barriers started. Prior to this study, a new type of concrete median barrier was suggested which is 1,270mm high and has no glare screens on top of it. So it was required to compare the properties of various types of concrete median barriers including the new type to find the optimal type of concrete median barrier. In this study, we have evaluated the characteristics of four types of concrete median barriers (New Jersey type, F type, constant slope type, and wall type). We have performed many computer simulations for the evaluation of the crashworthiness of them, and through the simulations we have tried to find a proper type of concrete median barrier. Through the computer simulations, we evaluated the structural stability and safety of the four types of concrete median barriers. We confirmed the structural stability and safety of them But in regard to the probability of "roll-over" of heavy vehicles, the higher concrete median barriers showed better performances than the lower. As the result of this study a new type of concrete median barrier was recommended.

Evaluation on Shear Behaviors of the Dapped Ends of Domestic Composite Double Tee Slabs under the Short-Term Loading (단기하중하의 국내 합성 더블티 슬래브 댑단부 전단거동 평가)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.774-781
    • /
    • 2002
  • Shear behaviors of eight dapped ends of four full-scale domestic single-tee slabs were evaluated. The dapped ends with 10cm topping concrete were designed based on live load requirements for the domestic parking lot of m 500kgf/㎡ and for the large market of 1,200 kgf/㎡. All specimens were designed by the ACI 318-99 design. The variations of the experiment were the shape of hanger reinforcements as followings: 1) general PCI design method(currently used in domestic), 2) 90 degree bent-up, 3) 60 degree bent-up. All experiments were conducted with 1.2 m shear span. The results obtained in this study were 1) all specimens fully complied with the shear strength requirements as specified by ACI 318-99 except for one strand bond slip specimen, 2)a specimen with the 60 degree bent up hanger reinforcing detail showed the best shear behaviors under full service and ultimate load, and 3)a specimen with the 90 degree bent up hanger reinforcing detail resulted in the worst shear behaviors.

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.