• Title/Summary/Keyword: 신호조절장치

Search Result 96, Processing Time 0.033 seconds

Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study (자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구)

  • Kim, Nam Young;Kim, Ju Hui;Lim, Jun;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Recently, magnetic resonance imaging (MRI), which can acquire images with good contrast without exposure to radiation, has been widely used for diagnosis. However, noise that reduces the accuracy of diagnosis is essentially generated when acquiring the MR images, and by adjusting the parameters, the noise problem can be solved to obtain an image with excellent characteristics. Among the parameters, the number of excitation (NEX) can acquire images with excellent characteristics without additional degradation of image characteristics. In contrast, appropriate NEX setting is required since the scan time increases and motion artifacts may occur. Therefore, in this study, after fixing all MRI parameters through the MRiLab simulation program, we tried to evaluate the tendency of image characteristics according to changing NEX through quantitative evaluation of brain T2 weighted images acquired by adjusting only NEX. To evaluate the noise level and similarity of the acquired image, signal to noise ratio (SNR), contrast to noise ratio (CNR), root mean square error (RMSE) and peak signal to noise ratio (PSNR) were calculated. As a result, both noise level and similarity evaluation factors showed improved values as NEX increased, while the increasing width gradually decreased. In conclusion, we demonstrated that an appropriate NEX setting is important because an excessively large NEX does not affect image characteristics improvement and cause motion artifacts due to a long scan.

Development of an UHF CW/FM Proximity Sensor System (UHF CW/FM 전파 근접 감지 시스템의 개발)

  • 최재현;임인성;한상철;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.4
    • /
    • pp.363-372
    • /
    • 1997
  • We have developed the UHF CW/FM proximity sensor system. The UHF CW/FM Proximity Sensor is the system which recognizes the distance from the antenna to the target using the UHF band signal. To adjust sensing distance, we must change modulation frequency parameter or modulation index parameter. When we select the modulation frequency paramter for adjusting sensing distance, new modulation frequency generator and new band pass filter will be required. It is so inefficient that we choose modulation index parameters for adjusting sensing distance. In this paper, theoretical principles of the UHF CW/FM Proximity Sensor are analyzed and doppler signals for the distance from the antenna to the target are measured as the modulation index($\beta$) being changed. Three systems of which moduation indices are 38, 50, and 61 are made. We concluded that the sensing distance will decrease as the modulation index($\beta$) increases. It is in accord with the theory of this UHF CW/FM Proximity Sensor System.

  • PDF

Embodiment of living body measure system modeling for Rehalibitation treatment of positive simulation for HRV algorithm analysis interface of Mobile base (모바일 기반의 HRV 알고리즘 분석 인터페이스에 대한 실증적 시뮬레이션의 재활치료용 생체계측 시스템 모델링의 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.4
    • /
    • pp.437-446
    • /
    • 2006
  • Mobilecomputer offers more fundamental role than role assistance enemy of modern technology equipment and new Information <중략> These main weakness puts in structural relation between elements that compose system. Therefore, dynamics research that time urea of systematic adjustment has selected method code Tuesday nerve dynamics enemy who groping of approach that become analysis point is proper and do with recycling bioelectricity signal. Nature model of do living body signal digital analysis chapter as research result could be developed and scientific foundation groping could apply HSS (Hardware-software system) by rehalibitation purpose. Special quality that is done radish form Tuesday of bioelectricity signal formation furthermore studied, and by the result, fundamental process of bodysignal in do structure circuit form of analog - digital water supply height modelling do can.

  • PDF

Study on Enhancements to Ultrasonic Data Imaging Using Full Matrix Capture Technique (Full Matrix Capture 기법을 통한 초음파신호 영상화 향상 연구)

  • Lee, Tae-Hun;Yoon, Byung-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.299-306
    • /
    • 2015
  • A conventional phased array system can control an ultrasonic beam electronically by adjusting the excitation time delay of individual elements in a multi-element probe and produce an ultrasonic image. In Contrast, full matrix capture (FMC) is a data acquisition process that allows receiving ultrasonic signals from one single shot of the phased array transducer element through all the other elements and captures the complete dataset from every possible transmit-receive combination. This FMC data can be used to create the ultrasonic image in post processing. It is possible to produce not only images equivalent to conventional phased array image but also total focusing method (TFM) images with improved resolution and sharpness, which is virtually focused at any point in a region of interest. In this paper, the system that can perform FMC by using a conventional phased array instrument is developed, and a study was conducted on the imaging algorithms to reconstruct sector B-scan and TFM images from FMC dataset.

A study on Power Quality Recognition System using Wavelet Transformation and Neural Networks (웨이블릿 변환과 신경회로망을 이용한 전력 품질 인식 시스템에 관한 연구)

  • Chong, Won-Yong;Gwon, Jin-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.169-176
    • /
    • 2010
  • Nonstationary power quality(PQ) signals which the Sag, Swell, Impulsive Transients, and Harmonics make sometimes the operations of the industrial power electronics equipment, speed and motion controller, plant process control systems in the undesired environments. So, this PQ problem might be critical issues between power suppliers and consumers. Therefore, We have studied the PQ recognition system in order to acquire, analyze, and recognize the PQ signals using the software, i.e, MATLAB, Simulink, and CCS, and the hardware. i.e., TMS320C6713DSK(TI), The algorithms of the PQ recognition system in the Wavelet transforms and Backpropagation algorithms of the neural networks. Also, in order to verify the real-time performances of the PQ recognition system under the environments of software and hardware systems, SIL(Software In the Loop) and PIL(Processor In the Loop) were carried out, resulting in the excellent recognition performances of average 99%.

Stable Standby-mode Implementation of Multi-output Power Supply using a New Load Current Estimation Technique with Linear Regulator (다중 출력 전원공급장치의 안정적 대기전력 구현을 위한 새로운 방식의 부하전류 측정기법 구현)

  • Lee, Jong-Hyun;Jung, An-Yeol;Kim, Dong-Joon;Park, Joung-Hu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.88-95
    • /
    • 2011
  • In this paper, a new standby-mode control method for multiple output switching-mode power-supply is suggested, which uses the control signal of the feedback compensator of the inner loop in the linear voltage regulator located at the transformer secondary side, as the load current information. Conventional method has a problem that standby mode occurs depending only on the load condition of the main controller output, which makes the other secondary side output very inaccurate by burst mode operation. The proposed method detects all the load current information and operates in burst mode only when the all of them are light load condition. Minimum of the additional components are required for the implementation of the proposed method because the load information is obtained from the existing feedback circuit of the post-stage linear regulator. In this paper, the operating principles of the proposed standby-mode circuit are presented with an numerical analysis, and are verified by 25W hardware prototype implementation.

Headspace-GC-MS에 의한 토양 중 MTBE와 BTEX의 동시분석법에 관한 연구

  • Sin Ho-Sang;An Hye-Sin;Ryu Sang-Hui;Kim Tae-Seung
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.31-35
    • /
    • 2005
  • 본 연구는 토양에 휘발유 첨가제인 MTBE와 휘발유의 주성분인 BTEX를 headspace 법에 의해 동시 분석하는 방법이다. 인산으로 pH를 2로 조절한 후 NaCl로 포화시킨 용액 5ml를 헤드스페이스 바이알에 보존제로 넣은 후 토양시료 약 2g을 이 용액에 침지시켜 시료 채취한 다음 헤드스페이스 장치에 넣고 $80^{\circ}C$에서 40분 가온하여 상부 기상의 일정량을 취해 GC-MS (SIM)으로 분석하였다. 본 분석법에 의한 검출한계는 methyl-tert-butyl ether(MTBE)와 benzene, toluene, ethylbenzene, o,m,p-xylene(BTEX)이 각각 0.1, 0.1, 0.1, 0.2, 0.1, 0.2 ng/g이었고, 직선성은 0.995이상이었으며, 재현성도 10%내외의 정밀한 값을 보였다. 실제 시료를 분석한 결과, MTBE가 3-6,993 ng/g의 농도분포를 보였고 total BTEX는 1 ng/g으로 검출되었다. 이 방법은 빠르고 정밀 정확한 분석법으로 공정시험법으로 활용가치가 높다.

  • PDF

Design of movable Tracking System using CDS Type Sensor (CDS센서를 이용한 이동 가능형 태양추적시스템 설계)

  • Sim, Myung-Gyu;Ji, Un-Ho;Chun, Soon-Yong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.6-11
    • /
    • 2010
  • Amount of power generated from solar photovoltaic can vary according to solar flux of sunlight due to nature of solar cell panel, and an angle that the sun and the surface of cell makes brings difference in amount of power generation. Solar flux is decided by location of surface of the Earth that is classified into longitude and latitude, but on the other hand, an angle that the sung and the surface of cell makes can be changed by changing the angle of a solar power generation device at the fixed location. A method of changing the angle of a solar power generation device as a measure for improving practical power generation efficiency. and studies about a solar tracking device for this are in active. This study conducted a research on a solar tracking system for improvement of solar power generation efficiency. A solar tracking system of this study is composed of a sensor part to confirm a location of the sun with a semiconductor photosensor using the photo conductive effect, and it analyzed output signal of a sensor by using microprocessor and it produced a control signal of driving part for tracking the sun. A solar power generator (25W) was produced to analyze performance of a solar tracking system and usefulness of a solar tracking device that was designed and produced in this study was confirmed through experiments.

Quantitative Evaluation of Image Quality using Automatic Exposure Control (AEC 사용 유무에 따른 영상의 화질평가)

  • Kim, Gwang-ho;Yoo, Gwan-ju;Kang, Ji-won;Ko, Bong-joo;Kim, Kyoun-lan;Kim, Min-hee;Yoon, Young-woo;Ye, Soo-young;Choi, Seok-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.86-89
    • /
    • 2015
  • Quantitative Evaluation of Image Quality using Automatic Exposure Control This it leads, the relationship of control and image between of photographing condition, DR proper use method proposing. Chest phantom acquires Chest PA images which it follows in conditional change, Image evaluation factor (SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), PSNR (Peak Signal to Ratio), RMS (Root Mean Square)). It excepted RMS price, SNR, CNR, PSNR the case which uses AEC it came out being high The fact that the quality of image is better there was a case which does not use AEC. but Price it was slight. Image qualitative it was deficient in AEC use presence. Through this, the overall situation and most efficient use of radiation workers is better suited. But Passive AEC use would be appropriate for use rather than proactive AEC.

  • PDF

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.