• Title/Summary/Keyword: 신축 아파트

Search Result 85, Processing Time 0.024 seconds

Study on the Crack Control Effect of Moist Curing Equipment in Side Wall of Building (습윤양생 장치를 이용한 아파트 측벽 균열제어에 관한 연구)

  • Kim, Dae-Geon;Lee, Dong-Woon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.127-134
    • /
    • 2017
  • In this study, moist curing equipment was used in the exist gang-form system. By achieving sufficient spray curing, the quality of the concrete was improved and the cracking occurred in building's side wall was decreased. The following results could be made as the conclusion. For the compressive strength, all zones showed the similar results. Comparing with the zone without using moist curing equipment, the zone used moist curing equipment showed higher rebound hardness results. For the cracking, the zone utilized moist curing equipment showed the cracking averaged as 6.6 m and the zone without using moist curing equipment showed the cracking averaged as 10.3m. The effectof reducing cracking by utilizing moist curing equipment is about 36 %. Using moist curing equipment is considered as a good solution to reduce the cracking in the structure. Considering all the factors analysed, using moist curing equipment improved the quality of the concrete and decreased the cracking. When this equipment was used in the construction site, it is expected that the construction periodcan be shrunk and the ratio of defect caused by drying shrinkage can be decreased. In this research conditions, The 0.3mm sized moist curing equipment provided the most desirable results on concrete quality and preventing cracking.

Analysis of Sunshine Amount for Education Environment according to Installation of Apartment Structures (아파트 구조물 설치에 따른 교육환경 일조량 분석)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • Due to recent urban maintenance project for the aged towns, the reconstruction of apartments into super-high-rise and high-rise apartment structures has been approved for concentrated use of land, and accordingly the infringement on sunshine for nearby residential area is rising as a social issue. Especially the educational environment conditions according to infringement on sunshine in educational facilities are posing many problems. Accordingly in this study, for such sunshine analysis of educational environment, Auto $CAD^{(R)}$ software has been used to construct the 3D model for the educational facility structures. And with the simulation technique, the windows and the schoolyard of the education facility were set to be the lighting standard surface to take measurements for the sunshine environment of the educational facilities by the minute from 8:00AM until 4:00PM for the sunshine amount by true solar time according to the movement of the sun. Also, the sunshine environment of the education facility according to the damage before/after new construction of apartments was charted, and through comparison with the video produced by sun shadow projection method, the sunshine amount of the educational environment could be verified. In future, it is expected to be efficiently used in the sunshine analysis of education environment utilizing such simulation techniques.

A Study on Sale revitalization Video Phone Market - The Case of Seoul City - (영상전화기(비디오폰) 판매 활성화방안 연구 - 서울시를 중심으로 -)

  • Kim, Dae-youn;Lee, Sang-youn
    • Journal of Distribution Science
    • /
    • v.7 no.1
    • /
    • pp.35-53
    • /
    • 2009
  • Sees the market where home appliance and network equipment, the communication service enterprises are new recently the home network market of the most which has an interest in the home network is being activated the newly-built high-class apartment in the center. The company building leads because not being option of the case last customer of newly-built market and must do a business . marketing. So newly-built market the demand grasp which is individual leads sale activation with difficult and that to creates a benefit there is a limit judges and axis market in the object hereafter demand at even the popular house the function to prepare in being magnified is simple and there is a possibility of saying that a more effort is demanded in supply style video phone market opening up where the price is cheap. Saw with like this reason from, analyzes the concept and a market trend of the video phone, grasps distribution channel forms and A/S handling systems and there is the goal finds the video phone sale revitalization plan which is suitable in all market.

  • PDF

Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments (신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석)

  • Choi, Yoon-Jung;Kang, Mi-Ra;Lee, Hye-Min;An, Hye-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments (신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응)

  • Choi Yoon-Jung;An Hye-Jung;Kang Mi-Ra;Lee Hye-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

A Study on the Flow Changes around Building Construction Area Using a GIS Data (GIS 자료를 활용한 신축 건물 주변 지역의 흐름 변화 연구)

  • Mun, Da-Som;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.879-891
    • /
    • 2018
  • In this study, the effects of urban redevelopment and building construction on the change of the detailed flows around the Pukyong National University (PKNU) campus located in the building-congested area was investigated using a CFD (computational fluid dynamics) model and GIS (geographic information system). For the analysis of the detailed flows before and after the constructions of the buildings around and within the campus, numerical simulations for the 16 inflow directions were performed before and after the construction. We used, as reference wind speeds at the inflow boundaries, the averaged wind speeds observed at the Gwangan light beacon (962) where there is no surrounding obstacle (i.e., building and terrain) acting as friction. We analyzed the area fractions in which wind speeds at z = 2.5 m changed after the construction for 16 inflow directions. The area fractions were relatively large in the east-south-easterly and southerly cases, because of the high-rise buildings constructed at the east and the apartment complex and the Engineering buildings constructed at the south of the PKNU campus. In the case of the easterly of which frequency is highest among the wind directions observed at the Daeyeon AWS (AWS 942) located inside the PKNU campus, the wind-speed change was not significant even after the constructions. It is shown that the building construction has affected the detailed flows around as well as even in the far downwind region of the constructed buildings. Also, it is shown that the GIS and CFD model are useful for analyzing the detailed flows in planning the urban redevelopment and/or building construction.

A Case of Sprinkler Non-Working by Programming Error (프로그래밍 오류에 의한 스프링클러 미작동 사례)

  • Seo, Young-Il;Cho, Young-Jin;Moon, Byung-Seon;Park, Jong-Jin;Park, Jong-Chan;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.116-120
    • /
    • 2008
  • According to the Fire Services Act revised in 2005, it has been required to set up sprinkler systems to all floors to the newly builded apartments having above 11 floors. But, according to the Fire Services Act before 2005, it had been required to set up sprinkler systems from 16 floors to the top floors to the apartments having above 16 floors. This case is the accident that a victim was dead by the fire which is inferred as an accidental fire by a cigarette butt in a 17th floor apartment unit in an apartment having 17th floors and that the bereaved family called in question why the sprinklers non worked at the fire. Through the field investigation, we checked that the sprinklers worked well when the fire detectors at the 16th floor of the apartment were operated and that the sprinklers non worked when the fire detectors at the 17th floor of the apartment were operated. We made clear that the cause of the sprinkler non-working at the 17th floor is the programming error of the sprinkler controller.

Study on the Characteristic of Floor Sound and Vibration Transfer and the Blocking Function of Floor Sound for Newly Built Apartment House (신축공동주택의 상하층간 소음 및 진동전달 특성과 층간소음 차단성능에 관한 연구)

  • Ham, Jin-Sik
    • Journal of the Korean housing association
    • /
    • v.24 no.2
    • /
    • pp.97-104
    • /
    • 2013
  • This study involves 2 newly built apartment houses which are A with 23 floors as 150 mm slab width and B with 16 floors as 180 mm slab width. The impact was added by tapping and bang machine at the middle floor level of these 2 apartments and the test was arranged in terms of the characteristic of vibration and sound level which transferred to upper or down floors. As a result, impact floor shows the highest value in terms of both sound and vibration level and followed was at down floor of the Impact floor. Also, blocking function for the lightweight and heavyweight floor impact sound level was tested for each room of the apartment A and B including living room, main room, room 1 and 2. As a result, sound blocking function of B apartment was better than that of A and the function was getting worse when the room size is getting smaller.

Analysis of on-site conditions of grounding methods installed in new buildings (신축 건물에 시설된 접지방식의 현장 실태 분석)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2208-2209
    • /
    • 2008
  • 최근 국제 표준 및 규격의 국내 도입에 따라 다양한 접지 방식에 대한 안전성과 신뢰성이 요구되고 있으나, 현재 국내 규정은 국제 규격과 부합되지 않는 측면이 있다. 따라서, 국내 건축물의 접지시스템에 대한 정확한 현장 실태를 바탕으로 국내 실정에 맞는 접지시스템의 개발이 요구되고 있다. 본 논문에서는 아파트, 공장, 상가, 학교 등의 신축 건물에 시설된 접지방식 및 등전위 본딩 실태 등을 현장 조사를 중심으로 분석하였다. 접지실태조사는 접지방식, 접지단자의 접속방식, 공결방식, 접지요소간의 접속방식 등을 분석하였으며, 등전위 본딩 실태조사는 IEC 60364에 규정된 방법을 근거로 계통외 도전성 부분과 기기외함의 연속성을 평가하였다.

  • PDF

Investigation of Shrinkage around Small Box of Short Span Slab (단경간 슬래브 중앙 소형박스(개구부)주변의 건조수축 거동 조사 연구)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.323-328
    • /
    • 2016
  • There are small box opening for inserting of electric lamp box in the slab of apartment. Around this box opening, we normally use the detailing of WWF or plastic ring strengthening to protect cracks induced by shrinkage. The shrinkage amount of slab box around was measured and analysed in order to consider validity of these strengthening methods and to find out economical alternative. Alternative of strengthening methods are normally used strengthening methods in construction companies, which are WWF strengthening, plastic ring strengthening and no strengthening methods. The shrinkage amount was measured using contact guage at the spot of tip attached around the box on slab of small area unit apartment which have small exclusive area below $59m^2$. Measured data shows that there are no big differences between all the 3 strengthening methods and Measure data range is $-264{\mu}{\varepsilon}{\sim}+216{\mu}{\varepsilon}$. Measured shrinkage is on trend slightly increase till 3~5weeks after removal of forms and then decrease. But amount of shrinkage are very low for all the slabs and there are no probabilities of concrete crack by shrinkage.