• Title/Summary/Keyword: 신축성 소재

Search Result 66, Processing Time 0.024 seconds

A Comparative Study on the Subjective Sensation and Tactile Preferences for Casual Shirt Fabrics Compared by the Nationality of Female University Students (여대생의 국적에 따른 캐주얼 셔츠 소재의 주관적 감각과 촉감 선호도 비교)

  • Meng, Yu;Choi, Jongmyoung
    • Science of Emotion and Sensibility
    • /
    • v.24 no.1
    • /
    • pp.105-114
    • /
    • 2021
  • This study determines the differences between Korean female university students and their Chinese counterparts residing in Korea by evaluating the subjective sensation and tactile preference in fabrics for casual shirts. Seven types of white causal shirt fabrics were selected as specimens from those available in spring and autumn shirt collection. The fabrics were made from various fibers (cotton 100%, polyester 100%, flax 100%, polyester 80%/cotton 20%, polyester 65%/cotton 35%, polyester 50%/cotton 45%/spandex 5%, and polyester 50%/modal 50%). Forty Korean and Chinese female university students subjectively assessed the subjective sensation of fabrics used for casual shirts. Participants were asked to observe the seven types of fabrics and complete the questionnaire. The subjective sensation to be assessed for white casual shirt fabrics was classified into the following four factors: smoothness, lightness, softness, and stretchiness. Subjective sensation factors showed partially significant differences by nationality. Korean female students evaluated cotton fabric as being light, whereas their Chinese counterparts evaluated the polyester/cotton/spandex blended fabric as light. Korean female students evaluated polyester/modal blended fabric as being stretchable. The tactile preference for fiber composition of the fabrics showed partially significant differences by nationality. Korean female students preferred cotton 80%/polyester 20% blended fabric, polyester 50%/cotton 45%/spandex 5% blended fabric, and flax 100% fabric. The subjective sensation of the fabrics had different effects on preferences by nationality. Smoothness and softness had positive effects on preferences for the fabrics of Korean students. However, smoothness, softness, and stretchiness had positive effects on the preferences of Chinese students. The subjective sensation and tactile preference for casual shirt fabrics showed a difference between Korean female students and their Chinese counterparts. Therefore, when planning casual shirt fabrics for female university students, it is necessary to reflect on these differences in subjective sensation and tactile preference.

Development of bio-inspired hierarchically-structured skin-adhesive electronic patch for bio-signal monitoring (생체정보 진단을 위한 생체모사 계층구조 기반 피부 고점착 전자 패치 개발)

  • Kim, Da Wan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.749-754
    • /
    • 2022
  • High adhesion and water resistance of the skin surface are required for wearable and skin-attachable electronic patches in various medical applications. In this study, we report a stretchable electronic patch that mimics the drainable structure pattern of the hexagonal channels of frog's pads and the sucker of an octopus based on carbon-based conductive polymer composite materials. The hexagonal channel structure that mimics the pads of frogs drains water and improves adhesion through crack arresting effect, and the suction structure that mimics an octopus sucker shows high adhesion on wet surfaces. In addition, the high-adhesive electronic patch has excellent adhesion to various surfaces such as silicone wafer (max. 4.06 N/cm2) and skin replica surface (max. 1.84 N/cm2) in dry and wet conditions. The high skin-adhesive electronic patch made of a polymer composite material based on a polymer matrix and carbon particles can reliably detect electrocardiogram (ECG) in dry and humid environments. The proposed electronic patch presents potential applications for wearable and skin-attachable electronic devices for detecting various biosignals.

The surface modification research of Polypropylene by plasma discharge (플라즈마 처리에 의한 Polypropylene 섬유의 표면개질 연구)

  • Lee, Chang-Seok;Kwon, Young-Mi;Ryu, Sun-A;Jo, Jang-Hoon;Jo, Hang-Sung
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.34-34
    • /
    • 2012
  • Polypropylene 섬유는 세계적으로 큰 관심을 모으고 있는 섬유 소재로 환경친화성, 경량성, 신축성 등 다양한 기능성을 보유하여 미국, 일본 등의 선진국에서 의류 및 인테리어용으로 채택하여 널리 사용되고 있다. 그러나, polypropylene 섬유는 다른 섬유에 비해 융점이 매우 낮아 내열성이 약하여 가공 공정시 고온을 피해야 하고, 곁가지가 거의 없고 섬유 분자 구조가 매우 조밀하며 탄소와 수소로만 이루어진 분자구조에 의한 극소수성 성질 때문에 다른 종류의 물질들과 접착력이 없어 사용에 제약을 주어 다양한 용도로의 활용이 제한되고 있는 실정이다. 본 연구에서는 Polypropylene 섬유의 제품화에 필요한 요소 기술의 기초를 마련하고자 대기압 플라즈마를 적용하여 소수성 표면을 지니는 표면을 친수화 함으로써 polypropylene 섬유에 후가공이 가능하도록 한다. 따라서 Plasma 표면 처리에 의해 polypropylene 섬유에 미치는 영향에 대하여 조사하고, 표면을 친수화 함으로써 습윤성, 접착성 등 다양한 가공 기술을 적용하여 PP 섬유의 기능성을 향상시키고자 한다. 플라즈마 처리에 의한 폴리프로필렌 섬유의 모폴로지 변화는 주사전자현미경 (FE-SEM)으로 확인하였으며 표면개질 효과는 Wicking Test로 평가하였다.

  • PDF

Development of Epoxy Based Stretchable Conductive Adhesive (신축 가능한 에폭시 베이스 전도성 접착제 개발)

  • Nam, Hyun Jin;Lim, Ji Yeon;Lee, Chang Hoon;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.3
    • /
    • pp.49-54
    • /
    • 2020
  • To attach a stretchable/flexible electrode to something or something to on electrode, conductive adhesives must be stretchable/flexible to suit the properties of the electrode. In particular, conductive adhesive require durability and heat resistance, and unlike conventional adhesives, they should also have conductivity. To this end, Epoxy, which has good strength and adhesion, was selected as an adhesive, and a plasticizer and a reinforcement were mixed instead of a two-liquid material consisting of a conventional theme and a hardener, and a four-liquid material was used to give stretchability/flexibility to high molecules. The conductive filler was selected as silver, a material with low resistance, and for high conductivity, three shapes of Ag particles were used to increase packing density. Conductivity was compared with these developed conductive adhesives and two epoxy-based conductive adhesives being sold in practice, and about 10 times better conductivity results were obtained than products being actually sold. In addition, conductivity, mechanical properties, adhesion and strength were evaluated according to the presence of plasticizers and reinforcement agent. There was also no problem with 60% tensile after 5 minutes of curing at 120℃, and pencil hardness was excellently measured at 6H. As a result of checking the adhesion of electrodes through 3M tape test, all of them showed excellent results regardless of the mixing ratio of binders. After attaching the Cu sheet on top of the electrode through conductive adhesive, the contact resistance was checked and showed excellent performance with 0.3 Ω.

Development of 2D Patterns for Cycling Pants using 3D Data of Human Movement and Stretch Fabric (동작시 3D 정보를 이용한 2D 패턴 전개 및 신축성 원단의 신장률을 고려한 사이클 팬츠 개발)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.19 no.3
    • /
    • pp.555-563
    • /
    • 2010
  • With recent advances in 3D scanning technology, three-dimensional (3D) patternmaking is becoming a powerful way to develop garments pattern. This technology is now applicable to the made to measure (MTM) system of both ordinary and tightly fitting garments. Although the pattern of fitted clothing has been developed using 3D human data, it is still interesting to develop cycling pants by considering while-cycling body posture and fabric elasticity. This study adopted the Garland's triangle simplification method in order to simplify data without distorting the original 3D scan. Next, the Runge-Kutta method (2C-AN program) was used to develop a 2D pattern from the triangular pixels in the 3D scanned data. The 3D scanned data of four male, university students aged from 21 to 25, was obtained using Whole body scanner (Model WB4, Cyberware, Inc., USA). Results showed the average error of measurement was $4.58cm^2$ (0.19%) for area and 0~0.61cm for the length between the 3D body scanned data and the 2D developed pattern data. This is an acceptable range of error for garment manufacture. Additionally, the 2D pattern developed, based on the 3D body scanned data, did not need ease for comfort or ease of movement when cycling. This study thus provides insights into how garment patterns may be developed for ergonomic comfort in certain special environments.

A Survey on the Ease of Jacket and Lining Fabrics that made of Stretchable Fabrics (국내 여성복 브랜드의 신축성 직물 재킷 및 안감 여유분 실태조사)

  • Kim, Myoung-Ok;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.15 no.2 s.67
    • /
    • pp.265-275
    • /
    • 2007
  • The purpose of this study is to analyze the ease of stretchable jackets which has been common since the mid-1990s and the whole actual conditions in making the lining fabrics. This can be done by investigating the actual conditions of domestic clothes businesses about the consumers. The outcomes of this study are as follows; The result of the survey in the differences of the ease between regular and stretchable fabrics shows that the pattern of designing stretchable fabrics needs diminishing the width of shoulder is 0.42cm, the whole girth chest is 1.83cm, the whole girth of waist is 0.88cm. It also shows that designing the ease of the whole girth of chest is 1.91cm to 2.54cm in the regular lining fabrics and is from 0 to 1.27cm in the stretchable fabrics more than the right side of fabrics. The ease of the whole girth of waist is similar to the round chest, in which the bottom sweep for garment is almost equal to the right side of fabrics in both regular lining fabrics and stretchable fabrics. The result of investigating the actual conditions of making the lining fabrics of stretchable jacket fabrics shows that 80% of a woman's wear brand produces and gives the pattern of the lining fabrics only for the special designing to the cooperative clothes manufactures. The business which always provides the patterns for the lining fabrics in the main office is only limited to 20%. Also, it shows that using the lining fabrics of stretchable jacket fabrics and regular lining fabrics together is 46.7%, the stretchable lining fabrics is 40% and the regular lining fabrics is 13.3% only.

  • PDF

Flexible Carbon/PDMS Composite for the Application of Sensor (신축성을 가진 Carbon/PDMS 복합체의 센서 응용 연구)

  • Lee, Junho;Park, Kyoung Ryeol;Mhin, Sungwook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.73-77
    • /
    • 2021
  • Flexible electrodes for wearable devices have been actively studied in not only achieving mechanical/electrical stability, but also providing various functionalities for extending its industrial application. In this study, a flexible carbon/PDMS composite is prepared by addition of carbon black (CB) as a conductive filler, and effect of CB with different contents on electrical properties of the composite was investigated for the application of flexible electrodes, temperature sensor and heater. With increase of CB contents, resistivity of the carbon/PDMS was increased, and excellent durability was observed, confirmed by repetitive stretching deformation test. Resistance increase of the carbon/PDMS with temperature reveals the property of positive temperature coefficient, which can be applied for temperature sensor. Also, joule heating on the carbon/PDMS was observed when electrical potential was applied, indicating the applicability of the carbon/PDMS for heater.

A Study on the Design of Smart Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing- (생체신호 모니터링 스마트 의류의 디자인 연구 -심전도 센싱 의류를 중심으로-)

  • Jo, Ha-Gyeong;Jo, Hyeon-Seung;Gu, Su-Min;Song, Ha-Yeong;Gang, Da-Hye;Lee, Ju-Hyeon;Lee, Jeong-Hwan;Lee, Yeong-Jae
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.05a
    • /
    • pp.123-126
    • /
    • 2009
  • 최근 생체 신호 센싱 기능의 의류가 연구 개발되어 왔으나, 생체 신호 측정 시 착용자의 동작에 의한 치명적인 잡음이 발생하는 문제가 지속적으로 보고되어 왔다. 이에 본 연구는 심전도 센싱 의류를 기반으로 생체 신호 측정의 정확성을 향상시키기 위하여 착용자의 동작에 의한 영향을 최소화할 수 있는 심전도 센싱 스마트 의류의 모형을 개발하고자 하였다. '일자형 절개 타입', '십자형 절개 타입', '엑스형 절개 타입', '곡선 엑스형 절개 타입'의 총 네 가지 타입의 생체신호 센싱 스마트 의류의 시안을 설계하고 제작하였다. 디자인 시안은 민소매 형태의 남성용 티셔츠로 신축성 있는 소재를 사용하여 인체 굴곡을 따라 의복과 전극이 밀착될 수 있도록 하였으며, 트랜스미터를 이용하여 메인 컴퓨터로 데이터가 무선 전송되게 하였다. 본 연구에서는 개발된 4 가지 의류 타임을 기반으로 인체의 정지 및 동작 상태에서의 심전도 센싱 성능을 평가하기 위해 동작에 따른 전극의 변위를 측정하고, 심전도 측정 평가를 실시하여 SNR을 분석하였다. 본 실험 곁과를 반영하여 의류 디자인 시안의 수정 및 보완 과정을 거친 후, 최종적으로 동작 잡음을 최소화하는 생체신호 센싱 스마트 의류 디자인 모형을 제시하였다.

  • PDF

Analysis of Physical Performance, Hygiene and Safety of Silicone-Laminated Stretch Material (실리콘이 라미네이팅된 신축성 소재의 위생 및 안전성과 역학적 성능)

  • Kwon, Myoung-Sook;Jung, Gi-Soo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.1 s.160
    • /
    • pp.77-84
    • /
    • 2007
  • The purpose of this study was to investigate and to compare the performances of silicone laminated materials sold for swimming cap in market, to get the basic data for product development. We selected 4 specimens and tested their air permeability, waterproofness and breathability. We also tested the physical and mechanical properties of the specimens using KES system. Silicone-laminated material was not bursted on high hydraulic pressure since silicone membrane gave waterproofness while PU/Polyester substrate gave elasticity. It didn't have air permeability and breathability at all. Any toxic materials such as Formaldehyde, Deldrin, PCP, Amin, TDBPP were not detected in silicone-laminated material and other materials. Silicone-laminated material had higher stretchability with the low force but it had lower elastic recovery and shape stability comparing to PU laminated material. It had lower flexibility than PU laminated material. It had lower unrecoverable amount in shearing direction. Friction coefficient was higher in silicone-laminated material than PU laminated material due to its surface stickiness. It was compressed easily and its compression resiliency was higher with compared to PU laminated material.

Study for the Liquid Metals Enabled Stretchable Electronics (액체금속을 활용한 신축성 전자소재 개발 동향)

  • Joo Hyung Lee;Yoon Su Lee;Jin Yoo;Seoyeon Won;Taehwan Lim
    • Journal of Industrial Technology
    • /
    • v.43 no.1
    • /
    • pp.25-31
    • /
    • 2023
  • Stretchable and flexible electronics that comply with dynamic movements and micromotion of the human tissues can enable real-time monitoring of physiologic signals onto the human skin and in the brain, respectively. Especially, gallium based liquid metal stretchable electronics can offer human-interactive biosensors to monitor various physiologic parameters. However, the liquid-like nature, surface oxidation and contamination by organic materials, and low biostability of the liquid metals have still limited the long-term use as bioelectronics. Here we introduced electrochemical deposition without oxidation pathways to overcome these practical challenges in liquid metal bioelectronics. CNT/PDDA composite with reduction way and PEDOT:BF4 with oxidation way under organic solvent are suggested as rationally designed material engineering approaches. We confirmed that the structures with the soft, flexible, and stretchable liquid metal platform can successfully detect dopamine with a high sensitivity and selectivity, record neural signals including action potentials without scar formation, and monitor physiologic signals such as EMG and ECG.