• Title/Summary/Keyword: 신뢰성 평가기준

Search Result 944, Processing Time 0.045 seconds

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

Reticulocyte hemoglobin content for the diagnosis of iron deficiency in young children with acute infection (급성 감염성 질환을 가진 영유아에서 철결핍 진단 지표로서의 망상적혈구혈색소량)

  • Kim, Jon Soo;Choi, Jun Seok;Choi, Doo Young;You, Chur Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.827-833
    • /
    • 2008
  • Purpose : Early identification of iron deficiency in young children is essential to prevent damaging long-term consequences. It is often difficult for the pediatrician to know which indices should be used when diagnosing these conditions especially in hospitalized young children. This study investigated the clinical significances of reticulocyte hemoglobin content in young children with acute infection. Methods : We studied 69 young children aged from 6 to 24 months admitted with acute infection in a single center. Venous blood was drawn to determine hemoglobin (Hb), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), hemoglobin content (CH), reticulocyte hemoglobin content (CHr), and red blood cell distribution width (RDW) using ADVIA 120 (Bayer Diagnostics, NY, USA). For evaluating iron status, iron, total iron binding capacity, ferritin and transferrin saturation (Tfsat) were determined. Iron deficiency was defined as Tfsat less than 20%, and iron deficiency anemia as Tfsat less than 20% and Hb level less than 11 g/dL. Results : In all, 47 were iron deficient; 17 of these had iron deficiency anemia. CHr was the only significant predictor of iron deficiency (likelihood ratio test=71.25; odds ratio=0.67; P<0.05). Plasma ferritin level had no predictive value (P=0.519). Subjects with CHr less than 27.4 pg had lower Hb level, MCH, CH, Tfsat, and iron levels than those with CHr 27.4 pg or more (P<0.05 for all). Conclusion : CHr level was a sensitive screening tool and the strongest predictor of iron deficiency in hospitalized infants with acute infection; it was cost saving and avoiding additional sampling. However its reference range should be established.

A Novel in Vitro Method for the Metabolism Studies of Radiotracers Using Mouse Liver S9 Fraction (생쥐 간 S9 분획을 이용한 방사성추적자 대사물질의 새로운 체외 측정방법)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Dong-Hyun;Lee, Sang-Yoon;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.325-329
    • /
    • 2004
  • Purpose: Usefulness of mouse liver S9 fraction was evaluated for the measurement of the metabolites in the in vitro metabolism study of $^{18}F$-labeled radiotracers. Materials and Methods: Mouse liver S9 fraction was isolated at au early step in the course of microsome preparation. The in vitro metabolism studies were tarried out by incubating a mixture containing the radiotracer, S9 fraction and NADPH at $37^{\ciirc}C$, and an aliquot of the mixture was analyzed at the indicated time points by radio-TLC. Metabolic defluorination was further confirmed by the incubation with calcium phosphate, a bone mimic. Results: The radiotracer $[^{18}F]1$ underwent metabolic defluorination within 15 min, which was consistent with the results of the in vivo method and the in vitro method using microsome. Radiotracer $[^{18}F]2$ was metabolized to three metabolites including $4-[^{18}F]fluorobenzoic$ acid within 60 min. It is likely that the one of these metabolites at the origin of radio-TLC was identical with the one that obtained from the in vivo and in vitro (microsome) method. Compared with the in vitro method using microsome, the method using S9 fraction gave a similar pattern of the metabolites but with a different ratio, which can be explained by the presence of cytosol in the S9 fraction. Conclusion: These results suggest that the findings of the in vitro metabolism studies using S9 fraction can reflect the in vivo metabolism of novel radiotracers in the liver. Moreover, this method can be used as a tool to determine metabolic defluorination along with calcium phosphate absorption method.

Evaluation of Neoadjuvant Chemotherapy Effect in Osteosarcoma (골육종에서 술전 항암화학요법의 효과 판정)

  • Joo, Min Wook;Kang, Yong-Koo;Yoo, Ie Ryung;Choi, Woo Hee;Chung, Yang-Guk;Kim, Dong-Hyun;Kang, Jin-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.66-73
    • /
    • 2014
  • Purpose: Various diagnostic imaging modalities have been used to evaluate the effect of neoadjuvant chemotherapy for osteosarcoma early and noninvasively. We evaluated the effectiveness of imaging studies of plain radiographs and positron-emission tomography/computed tomography (PET/CT) in predicting neoadjuvant chemotherapy effect for osteosarcoma and tried to establish a general principle in interpretation of PET/CT parameters. Materials and Methods: Eighteen patients who underwent two cycles of neoadjuvant chemotherapy and surgical excision for osteosarcoma were enrolled. There were 13 males and 5 females, with a median age of 19 (11-63) years. Fifteen patients of 18 had the American Joint Committe on Cancer (AJCC) stage IIB. They had plain radiographs and PET/CT before and after neoadjuvant chemotherapy. The resected tumor specimens were pathologically examined to determine histological response grade using a conventional mapping method. Statistical analysis was performed to evaluate the correlation between histopathological necrosis rate, and radiographic finding category, post-chemotherapy maximum standardized uptake value (SUVmax), average standardized uptake value and metabolic tumor volume (MTV) as well as reduction rates of them. Results: Eight patients were good responders to neoadjuvant chemotherapy based on histological evaluation. Median SUVmax reduction rate was 73 (23-77) % in good responders and 42 (-32-76) % in poor responders. Median MTV reduction rate was 93.5 (62-99) % in good responders and 46 (-81-100) % in poor responders. While radiographic finding category was not different according to histological response (p=1.0), SUVmax reduction rate was significantly different (p=0.041). Difference in MTV reduction rates approached statistical significance as well (p=0.071). Conclusion: While radiographic finding category was not reliable to assess neoadjuvant chemotherapy effect for osteosarcoma, reduction rate of SUVmax was a useful indicator in this study. As parameters of PET/CT can be influenced by various factors of settings, different centers have to make an effort to establish their own standard of judgement with reference of previous studies.

A Study of Inter-observer Agreements of Spiral Chest Computed Tomography in Diagnosing Pulmonary Embolism (폐색전증에서 나선형 컴퓨터 전산화 단층촬영의 관찰자간의 일치도에 관한 연구)

  • Kim, Yang-Ki;Lee, Young Mok;Kim, Ki-up;Uh, Soo-taek;Kim, Yong Hoon;Park, Choon Sik;Hwang, Jung-Hwa;Kim, Dong Hun;Goo, Dong-Erk;Choi, Deuk-Lin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.473-479
    • /
    • 2005
  • Background : A pulmonary embolism often presents with nonspecific symptoms and signs. However, a delayed diagnosis can result in catastrophic outcome. The majority of preventable deaths associated with a pulmonary embolism can be ascribed to a missed diagnosis rather than to the failure of existing treatments. Therefore, accurate and rapid diagnostic methods are essential for the management of a pulmonary embolism. The recent generation of multidetector-row spiral CT scanners appears to outperform other imaging modalities in detecting a central and peripheral pulmonary embolism. However, there are some variations in the interpretations of the findings between observers. This study examined the inter-observer differences of the diagnoses in patients with a pulmonary embolism. Method : 64 patients who were diagnosed with a pulmonary embolism either clinically or with spiral chest CT from 2002 to 2004, were included. Two thoracic radiologists interpreted the multidetector-row spiral CT in terms of the diagnosis of a pulmonary embolism and the location of the thrombus independently. Among 64 patients, 14 patients were excluded because there was no evidence of a pulmonary embolism or there was different interpretation of the pulmonary embolism between radiologists. A clinical diagnosis was based on "Rules for predicting the probability of embolism". Results : The mean score of the patients according to the Wells method was $3.91{\pm}0.30$ (0-9). The accordance of the radiologists was 95% in the main, 85% in the lobar, 91.2% in the segmental, and 96% in the sub-segmental pulmonary arteries. After excluding the negative interpretation from both radiologists, their agreement was 76.2%(${\kappa}.$ 0.83) in the main, 57.6%(${\kappa}.$ 0.63) in the lobar, 51.5%(${\kappa}.$ 0.63) in the segmental, and 34.6%(${\kappa}.$ 0.49) in the sub-segmental pulmonary arteries. Conclusion : Chest CT has been recently applied to patients suspected of having a pulmonary embolism. It was found that spiral CT is a rapid test for diagnosing a thrombus, and there was reliable accordance between the observers from the area of the large pulmonary arteries. However, there was a lack of agreement between the observers in diagnosing thrombi located distal to the sub-segmental arteries.

Estimation for Red Pepper(Capsicum annum L.) Biomass by Reflectance Indices with Ground-Based Remote Sensor (지상부 원격탐사 센서의 반사율지수에 의한 고추 생체량 추정)

  • Kim, Hyun-Gu;Kang, Seong-Soo;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.2
    • /
    • pp.79-87
    • /
    • 2009
  • Pot experiments using sand culture were conducted in 2004 under greenhouse conditions to evaluate the effect of nitrogen deficiency on red pepper biomass. Nitrogen stress was imposed by implementing 6 levels (40% to 140%) of N in Hoagland's nutrient solution for red pepper. Canopy reflectance measurements were made with hand held spectral sensors including $GreenSeeker^{TM}$, $Crop\;Circle^{TM}$, and $Field\;Scout^{TM}$ Chlorophyll meter, and a spectroradiometer as well as Minolta SPAD-502 chlorophyll meter. Canopy reflectance and dry weight of red pepper were measured at five growth stages, the 30th, 40th, 50th, 80th and 120th day after planting(DAT). Dry weight of red pepper affected by nitrogen stress showed large differences between maximum and minimum values at the 120th DAT ranged from 48.2 to $196.6g\;plant^{-1}$, respectively. Several reflectance indices obtained from $GreenSeeker^{TM}$, $Crop\;Circle^{TM}$ and Spectroradiometer including chlorophyll readings were compared for evaluation of red pepper biomass. The reflectance indices such as rNDVI, aNDVI and gNDVI by the $Crop\;Circle^{TM}$ sensor showed the highest correlation coefficient with dry weight of red pepper at the 40th, 50th, and 80th DAT, respectively. Also these reflectance indices at the same growth station was closely correlated with dry weight, yield, and nitrogen uptake of red pepper at the 120th DAT, especially showing the best correlation coefficient at the 80th DAT. From these result, the aNDVI at the 80th DAT can significantly explain for dry weight of red pepper at the 120th DAT as well as for application level of nitrogen fertilizer. Consequently ground remote sensing as a non-destructive real-time assessment of plant nitrogen status was thought to be a useful tool for in season nitrogen management for red pepper providing both spatial and temporal information.

Bioequivalence Evaluation of Two Cefquinome 2.5% Injectable Products in Piglets (돼지에서 두 가지 Cefquinome 2.5% 제제의 생물학적 동등성 평가)

  • Song, In-Bae;Kim, Tae-Won;Lee, Hong-Gee;Kim, Myoung-Seok;Hwang, Youn-Hwan;Park, Byung-Kwon;Lim, Jong-Hwan;Yun, Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.233-236
    • /
    • 2012
  • Cefquinome, a fourth generation cephalosporin, has been solely used for veterinary medicine and has a broad antibacterial spectrum against gram-negatives and gram-positives being very stable to ${\beta}$-lactamases. This study was conducted to evaluate the bioequivalence of two cefquinome 2.5% products in piglets. Plasma cefquinome concentrations were analyzed by liquid chromatography-mass spectrometry (LC/MS). Mean maximum concentration ($C_{max}$) of test product ($Cequus^{(R)}$) and reference product ($Cobactan^{(R)}$) were $4.34{\pm}0.58$ and $4.22{\pm}0.47{\mu}g/mL$, and mean area under the concentration time curve ($AUC_{0{\rightarrow}{\infty}}$) values were $10.43{\pm}1.96$ and $10.25{\pm}2.98{\mu}g{\cdot}h/mL$, respectively. The 90% confidence intervals for the ratio of $C_{max}$ (0.941-1.115), and $AUC_{0{\rightarrow}{\infty}}$ (0.927-1.172) values for the test and reference products were within the acceptable bioequivalence limit of 0.80-1.25. It is concluded that two commercial cefquinome injectable solutions are bioequivalent in their extent of drug absorption in piglets.

Evaluation of the behavior and quality in soil moisture data: A case study of Yongdam study watershed (토양수분 데이터의 거동 및 품질 평가: 용담시험유역 사례연구)

  • Lee, Seulchan;Baik, Jongjin;Choi, Minha;Cho, Younghyun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.12
    • /
    • pp.951-962
    • /
    • 2019
  • Producing consistent, accurate soil moisture data to be utilized as a reference dataset for researches related to hydrological cycle and natural disaster is being critical, but such techniques (e.g. quality control) are still limited to improve reliability of soil moisture data. In this study, analyses of soil moisture's behavior and quality control based on International Soil Moisture Network's (ISMN's) criteria were carried out in Yongdam study watershed, which is UNESCO-IHP' representative examination area in South Korea, to suggest a direction to improve the quality of soil moisture data. The results of the behavior analysis showed normal increasing/decreasing patterns following precipitation events in all stations except two (i.e. Bugui, Ancheon). As a result of applying quality flagging technique, there were no observation recordings in abnormal range, and freezing of soil moisture occurred within general range (~20%). Soil moisture rise without prior rainfall appeared about 4% and there were less than 0.01% for spike and 5% for plateau. Producing more reliable reference data will be possible if site-specific criteria for quality control are considered enough in the future.

Use and Perception of Environmentally-Friendly Ingredients by Dietitians in Chungbuk (충북지역 학교급식 영양(교)사의 친환경 식재료에 대한 이용실태 및 인식)

  • Jung, Sang Hee;Lee, Young Eun;Park, Eun Hye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1567-1582
    • /
    • 2015
  • The purpose of this study was to examine the status of environmentally-friendly ingredients and dietitians' perceptions toward them in order to find for improvement. Data was collected from questionnaires completed by 202 school dietitians and nutrition teachers in Chungbuk, and this data was analyzed utilizing the SPSS 20.0 program. The results obtained from this study were as follows: 'mixed grains (58.9%)' and 'eggs (36.6%)' were found to be the most used environmentally-friendly ingredients. 81.7% of the respondents said they 'never used' marine products, whereas 'fruits (43.6%)', 'pork (40.8%)', and 'fish (54.5%)' were the most preferred ingredients. Dietitians and nutrition teachers used environmentally-friendly marine products less than other ingredients, had a poor understanding about environmentally-friendly marine products, and demonstrated low reliability and belief in the necessity of the system. In order to verify the environmentally-friendly status of the ingredients, marks on the product and documents of certification were mostly used. In order to improve the supply system, a more strict tracking system in the distribution process by securing more reliable suppliers is required.

Asbestos Exposure and Health Risk Assessment for the Residents Near the Abandoned Mining Area in Chungbuk, Korea (충북지역 폐석면광산 인근주민의 석면노출과 건강위해도 평가)

  • Shin, Jin-Ho;Oh, Seok-Ryul;Hwang, Soon-Yong;Chung, Sook-Nye;Kim, Ji-Hui;Nam, Eun-Jung;Lee, Jin-Hyo;Choi, Hee-Jin;Eom, Seok-Won;Chae, Young-Zoo;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.345-350
    • /
    • 2012
  • To investigate the exposure and health risk assessment for the residents near the D-asbestos mine in Chungbuk, Korea. We analyzed asbestos in the 20 ambient air and 23 activity based samples near the mine. The airborne sample results are showed that 8 of 20 samples ranged between 0.0025 to 0.0029 f/cc (fiber per cubic centimeter) and the others were below the detection limit by phase contrast microscopy (PCM). In addition, asbestos fibers were under the detection limit or not being by transmission electron microscopy (TEM). Based on interview and survey targeting the local residents, we made the activity based sampling (ABS) scenarios fit to the conditions of field. At the same time, we calculated the excess lifetime cancer risk (ELCR) of these ABS scenarios according to the ELCR average value and 95% upper confidence limit (UCL). At the case of weed whacking, soil digging and sweeping yard scenario, 95% UCL of ELCR exceeded the $1{\times}10^{-4}$, acceptable risk range for exposure. Based on our study results, it is necessary safety measures such as risk communication, abatement or management of naturally occurring asbestos (NOA).