• Title/Summary/Keyword: 시험비용

Search Result 1,090, Processing Time 0.029 seconds

A Study on Information Collection and Idea Creation Using Drones (드론을 활용한 정보수집 및 아이디어 창출에 관한 연구)

  • Jo, Hwani;Yoo, Jaewon;Choi, Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.117-124
    • /
    • 2024
  • The objective of Value Engineering (VE) is to derive the optimal value at the most efficient life cycle cost, comprising three stages: Pre-Study, Study, and Post-Study. In this study, we propose a method for information collection and analysis during planned site visit surveys in the preparation stage of VE. The 3D spatial model, created using a drone, facilitated observation and analysis of the study area from various angles, both from the center and the outside. Additionally, through the utilization of drones, we conducted on-site investigations of the research area's 3D spatial model, enabling a macroscopic perspective previously only feasible through a microscopic viewpoint during planned site visits in the pre-study phase. Furthermore, the utilization of actual spatial data obtained from observations allowed for real-time information verification during Design VE workshops, enhancing the efficiency and reliability of the VE project.

Toxicity prediction of chemicals using OECD test guideline data with graph-based deep learning models (OECD TG데이터를 이용한 그래프 기반 딥러닝 모델 분자 특성 예측)

  • Daehwan Hwang;Changwon Lim
    • The Korean Journal of Applied Statistics
    • /
    • v.37 no.3
    • /
    • pp.355-380
    • /
    • 2024
  • In this paper, we compare the performance of graph-based deep learning models using OECD test guideline (TG) data. OECD TG are a unique tool for assessing the potential effects of chemicals on health and environment. but many guidelines include animal testing. Animal testing is time-consuming and expensive, and has ethical issues, so methods to find or minimize alternatives are being studied. Deep learning is used in various fields using chemicals including toxicity prediciton, and research on graph-based models is particularly active. Our goal is to compare the performance of graph-based deep learning models on OECD TG data to find the best performance model on there. We collected the results of OECD TG from the website eChemportal.org operated by the OECD, and chemicals that were impossible or inappropriate to learn were removed through pre-processing. The toxicity prediction performance of five graph-based models was compared using the collected OECD TG data and MoleculeNet data, a benchmark dataset for predicting chemical properties.

A Study on the System Management CSCI Software Modularization in Naval Combat Management System

  • Hyeon-Tae Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.8
    • /
    • pp.67-75
    • /
    • 2024
  • Frequently changeable functional requirements in System Management CSCI Software make it difficult to reuse an overall application, but only the partial class codes repeatedly as a new version of Naval Combat Management System is developed. This structural environment leads to increasing development time and expenses. This is why modularization for System Management CSCI Software is proposed as a solution, leveraging the advantages of proper standardization and functional expandability offered by Standard Interface Architecture. This paper outlines the comparisons of modified class ratios as well as software reliability test runtime results between before and after implementing the modularization for System Management CSCI Software. The findings demonstrate there is sufficient improvement in areas, such as higher maintenance and reusability, supporting the application of modularization for System Management CSCI Software with the implementation of Standard Interface Architecture.

A Simplified Method for Evaluating Damage of Caisson-Type Quay Wall During Earthquakes (지진시 케이슨식 안벽의 피해 예측을 위한 간편법 개발)

  • Hyeonsu Yun;Minje Back;Jiahao Sun;Seong-Kyu Yun;Gichun Kang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.3
    • /
    • pp.1-14
    • /
    • 2024
  • To better prepare for the increasing frequency of earthquakes, securing the seismic performance of coastal structures is more urgent than ever. Evaluating the stability of coastal structures precedes ensuring seismic performance. Methods for assessing stability during earthquakes include finite element analysis and model testing. However, these methods have the disadvantage of requiring significant cost and time. Therefore, this study aimed to propose a simplified method for quickly and easily predicting the horizontal displacement of caisson-type qual wall structures during earthquakes. Initially, existing simplified methods were compared and analyzed against numerical analysis. The results revealed limitations in predicting the displacement of caisson-type qual wall using existing simplified methods. To address this, correction coefficients related to the backfilled ground N value, velocity's PSI, and the W/H ratio were added to the existing simplified method. After the adjustments, a noticeable reduction in errors was observed, demonstrating high precision within the 200 gal range.

Sudies on the Effect of a New Compound Fertilizer for Application for Barely (대맥(大麥)에 대(對)한 맥기비용(麥基肥用) 신개발(新開發) 복합비료(複合肥料)의 비효에 관(關)한 연구(硏究))

  • Kim, Kwang Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 1978
  • A field experiment was conducted on a recently reclaimed hillside land to investigate the effectiveness of newly formulated compound fertilizer (10-14-11) containing fused phosphate as phosphorus source. Winter barley was adopted as a crop and commercial compound fertilizer (22-22-11), triple superphosphate, and ordinary fused phosphate were compared with the new compound fertilizer. The result of present study is summarized as follows. 1. When viewed from the plant hight and dry matter yield observed at different growth stages, it was indicated that newly formulated compound fertilizer seemed to be more effective in late stage than early stage. 2. Grain yields were higher in the compound fertilizer plots compared to the triple superphosphate and fused phosphate plots. The yield was specially high in the newly formulated compound fertilizer plot. In this plot, the number of grain per panicle and the rate of maturity were higher than the other plots. 3. The amount of phosphorus uptake by plant in the newly formulated compound fertilizer was lower in early stage and higher in late stage. In this experiment, the magnesium and silica contained in fused phosphate did not influence the growth and yield of barley because the soil was relatively high in these components. 4. Because of the unprecedented severity of winter weather during the experiment, the result obtained in present study may not be generalized until some studies confirm present findings.

  • PDF

Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile (대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석)

  • Park, Sangwoo;Sung, Chihun;Lee, Dongseop;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.5-21
    • /
    • 2015
  • An energy pile is a novel type of ground heat exchangers (GHEX's) which sets up heat exchange pipes inside a pile foundation, and allows to circulate a working fluid through the pipe for exchanging thermal energy with the surrounding ground stratum. Using existing foundation structure, the energy pile can function not only as a structural foundation but also as a GHEX. In this paper, six full-scale energy piles were constructed in a test bed with various configurations of the heat exchange pipe inside large-diameter cast-in-place piles, that is, three parallel U-type heat exchangers (5, 8 and 10 pairs), two coil type heat exchangers (with a 500 mm and 200 mm pitch), and one S-type heat exchanger. During constructing the energy piles, the constructability of each energy pile was evaluated with consideration of the installation time, the number of workers and any difficulty for installing. In order to evaluate the thermal performance of energy piles, the thermal performance tests were carried out by applying intermittent (8 hours operating-16 hours pause) artificial cooling operation to simulate a cooling load for commercial buildings. Through the thermal performance tests, the heat exchange rates of the six energy piles were evaluated in terms of the heat exchange amount normalized with the length of energy pile and/or the length of heat exchange pipe. Finally, the economic feasibility of energy pile was evaluated according to the various types of heat exchange pipe by calculating demanded expenses per 1 W/m based on the thermal performance test results along with the market value of heat exchange pipes and labor cost.

Characterization of Cement Solidification for Enhancement of Cesium Leaching Resistance (세슘 침출 저항성 증진 시멘트 고화체의 제조 및 특성 평가)

  • Kim, Gi Yong;Jang, Won-Hyuk;Jang, Sung-Chan;Im, Junhyuck;Hong, Dae Seok;Seo, Chel Gyo;Shon, Jong Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.183-193
    • /
    • 2018
  • Currently, the Korea Atomic Energy Research Institute (KAERI) is planning to build the Ki-Jang Research Reactor (KJRR) in Ki-Jang, Busan. It is important to safely dispose of low-level radioactive waste from the operation of the reactor. The most efficient way to treat radioactive waste is cement solidification. For a radioactive waste disposal facility, cement solidification is performed based on specific waste acceptance criteria such as compressive strength, free-standing water, immersion and leaching tests. Above all, the leaching test is important to final disposal. The leakage of radioactive waste such as $^{137}Cs$ causes not only regional problems but also serious global ones. The cement solidification method is simple, and cheaper than other solidification methods, but has a lower leaching resistance. Thus, this study was focused on the development of cement solidification for an enhancement of cesium leaching resistance. We used Zeolite and Loess to improve the cesium leaching resistance of KJRR cement solidification containing simulated KJRR liquid waste. Based on an SEM-EDS spectrum analysis, we confirmed that Zeolite and Loess successfully isolated KJRR cement solidification. A leaching test was carried out according to the ANS 16.1 test method. The ANS 16.1 test is performed to analyze cesium ion concentration in leachate of KJRR cement for 90 days. Thus, a leaching test was carried out using simulated KJRR liquid waste containing $3000mg{\cdot}L^{-1}$ of cesium for 90 days. KJRR cement solidification with Zeolite and Loess led to cesium leaching resistance values that were 27.90% and 21.08% higher than the control values. In addition, in several tests such as free-standing water, compressive strength, immersion, and leaching tests, all KJRR cement solidification met the waste acceptance or satisfied the waste acceptance criteria for final disposal.

Studies on the Evaluation of Kenaf as a Bulking Agent in Livestock Composting (가축 분뇨의 퇴비화 수분 조절제로서 Kenaf의 유용성 평가)

  • Lim, Jeong-Ju;Kim, Dong-Hyeok;Lee, Jin-Ju;Kim, Dae-Geun;Lee, Hu-Jang;Min, Wongi;Park, Dongjin;Huh, Moo-Ryong;Chang, Hong-Hee;Kim, Pil-Joo;Kim, Suk
    • Journal of agriculture & life science
    • /
    • v.45 no.2
    • /
    • pp.21-28
    • /
    • 2011
  • Hibiscus cannabinus L is a plant in the Malvaceae family. Kenaf was seeded at June 1st in 2010 and harvested at November 18th and dried and evaluated worth as a bulking agent for livestock composting. Harvested and dried Kenaf was divided into the bast, core and leaf. All materials were grinded by hammer mill and the moisture absorption, moisture evaporation, pH, volume weight and C/N ratio were measured. Kenaf was higher water absorption and evaporation ability than those of sawdust and chaff. The pH values of Kenaf were pH $2.8{\pm}0.01$ - $4.34{\pm}0.02$, which is lower pH value than those of sawdust (pH $5.28{\pm}0.01$) and chaff (pH $6.3{\pm}0.02$). The C/N ratio of Kenaf showed 649 of core, 204 of bast and 70 of leaf, which were lower than sawdust (789.1) but higher than chaff (132). In volume weight test, the materials were divided by particle size of Kenaf, named as group A(${\geq}4cm$), B(${\leq}4cm$, ${\geq}0.25cm$) and C(${\leq}0.25cm$). The volume of weight of group A and B for core, bast and leaf showed similar, but group C showed higher than those of sawdust and chaff. Especially, the volume weight of group C for leaf was 5 times higher than those of sawdust and chaff. This study suggested the possibility of using Kenaf as a bulk agent for composting of livestock manure. This is considered that strengthen the competitiveness of farmers through reducing the cost, prevention of environmental pollution caused by livestock manure and environmentally friendly processing of livestock manure.

Studies on sterile filters in the preparation of N-13 ammonia injection (N-13 암모니아 주사액 제조 시 멸균필터의 흡착율 차이에 관한 비교 평가)

  • Oh, Chang Bum;Kim, Si Hwal;Cha, Min Jung;Shin, Jin;Ji, Yong Gi;Choi, Sung Ook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.64-68
    • /
    • 2019
  • Purpose In the preparation process for N-13 Ammonia injections, there were radioactive medicines adsorbed on filters remarkably. Hereby, we have compared the adsorption rate and quality test on Millex GS filter and Satorious Minisart filter, both representatively hydrophilic sterilizing filters, also evaluated which filter is more accommodative for N-13 Ammonia injection. Materials and Methods The filters used for sterilization of N-13 Ammonia injections were Millex GS filter($0.22{\mu}m$) mand Satorious Minisart filter ($0.2{\mu}m$), which are generally used to strain aqueous solutions. After the N-13 Ammonia passes through each sterilization filter, the adsorption rate of the filter (n=10) is determined by measuring not only the radioactivity through the filter also the amount of radioactivity remaining in it using a Dose Calibrator. The N-13 Ammonia injections after each filter is tested by the quality control test to conform to the Samsung Medical Center standard. Results The ratio of radioactivity passed through Millex GS indicated $29.0{\pm}17.6%$. Satorious Minisart filters output was $80.9{\pm}3.2%$, respectively. Each ratio of radioactivity adsorbed on the sterile filter was $71.0{\pm}17.6%$ for Millex GS and $19.1{\pm}3.2%$ for the Satorious Minisart filters, respectively. Furthermore, on the ratio of filtered radioactivity, Using Satorious Minisart filter showed about 2.8 times higher than using Millex GS filter. The quality testing of N-13 Ammonia injections through each filter met the Samsung Medical Center standard. Conclusion The Millex GS filter is composed of cellulose acetate and cellulose nitrate, whereas the Satorious Minisart filter if composed only of cellulose acetate. Therefore, the presence of cellulose nitrate in the membrane seems to have made differences. Therefore, the use of Satorious Minisart filter in the preparation of N-13 Ammonia injection solution minimized the loss of radioactive medicines due to filter adsorption, thereby improving the synthesis yield.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF