• Title/Summary/Keyword: 시스템 사고 정의

Search Result 339, Processing Time 0.028 seconds

Detection of Illegal U-turn Vehicles by Optical Flow Analysis (옵티컬 플로우 분석을 통한 불법 유턴 차량 검지)

  • Song, Chang-Ho;Lee, Jaesung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.10
    • /
    • pp.948-956
    • /
    • 2014
  • Today, Intelligent Vehicle Detection System seeks to reduce the negative factors, such as accidents over to get the traffic information of existing system. This paper proposes detection algorithm for the illegal U-turn vehicles which can cause critical accident among violations of road traffic laws. We predicted that if calculated optical flow vectors were shown on the illegal U-turn path, they would be cause of the illegal U-turn vehicles. To reduce the high computational complexity, we use the algorithm of pyramid Lucas-Kanade. This algorithm only track the key-points likely corners. Because of the high computational complexity, we detect center lane first through the color information and progressive probabilistic hough transform and apply to the around of center lane. And then we select vectors on illegal U-turn path and calculate reliability to check whether vectors is cause of the illegal U-turn vehicles or not. Finally, In order to evaluate the algorithm, we calculate process time of the type of algorithm and prove that proposed algorithm is efficiently.

A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station (수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구)

  • Hwayoung, Lee;Hyeonwoo, Jang;Minkyung, Lee;Jeonghwan, Kim;Jaehun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.30-36
    • /
    • 2022
  • In commercial transactions of energy sources using hydrogen charging stations, high-accuracy flow meters are needed to prevent accidents such as overcharging due to inaccurate measurements and to ensure transparency in hydrogen commercial transactions through accurate measurements. This research developed a Corioli-type flowmeter prototype and conducted a risk assessment to prevent accidents during a process change comparison experiment for existing charging stations to verify the measurement performance. A process change section was defined for the installation of measurement facilities for empirical experiments and HAZOP was conducted. In addition, JSA was also conducted to secure the safety of experimenters, such as preventing valve mis-opening during empirical experiments. Measures were established to improve the risk factors derived through HAZOP, and work procedures were established to minimize human errors and ensure the safety of workers through JSA. The design change and system manufacturing for the installation of the metering system were completed by reflecting the risk assessment results, and safety could be confirmed through the performance comparison test of the developed meter prototype. The developed prototype flow meter showed a total of 30 flow measurements under the operating conditions of 70 MPa, and the average error was -1.58% to 3.96%. Such a metering error was analyzed to have the same performance as a flow meter installed and operated for commercial use.

Risk Assesment of Subsidence which utilized Fuzzy-FMEA (Fuzzy-FMEA를 활용한 지반함몰 위험도 평가)

  • Deacheon Kim;YoungMin Jung;Dongil Shin
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.313-325
    • /
    • 2023
  • Purpose: According to the recent occurrence statistics of ground accidents, ground subsidence and subsidence have become social problems as the frequency has increased centering around the downtown areas. This study tried to clarify risk of detailed factors which have an effect on subsidence. Method: For the study, detailed risk factors of 28 foundations were mainly drawn through the materials, precedent studies, and research reports shown by analyzing JIS' accident cases from 2016 to September 6, 2022 and by taking advice from an excavation expert. And risk was assessed by conducting a survey on 12 subsidence experts from the universities, research institutes, and industries and applying Fuzzy-FMEA to it. Result: It has found that damage of sewer pipes is 24.99% of overall risk, followed by excavation work (17.34%), water pipes (14.84%), and poor compaction (refill) (13.93%). And it has found that risk of damaging utilities (water pipes, sewer pipes, and other utilities) is highest, followed by poor construction works (excavation work, damage of sewer and water pipes, and other utility work) and poor compaction (refill). Conclusion: This shows that risk of subsidence factors judged by experts is similar with JIS' cases of ground subsidence.

Re-chlorination facility design to cope with virus intrusion in water distribution system (상수도 관망 내 바이러스 유입 대응을 위한 재염소 시설 설계)

  • Kim, Beomjin;Lee, Seungyub
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.4
    • /
    • pp.277-287
    • /
    • 2024
  • Water distribution system (WDS) is exposed to various water quality incidents during its operation. This study utilized Quantitative Microbial Risk Assessment (QMRA) to analyze the risk associated with potential virus intrusion in WDSs. Additionally, the study determined the location and operation of rechlorination facilities to minimize potential risk. In addition, water quality resilience was calculated to confirm that the chlorine concentration maintains within the target range (0.1-1.0 mg/L) during normal operation. Hydraulic analysis was performed using EPANET, while EPANET-MSX was linked to simulate the reactions between viruses and chlorine. The proposed methodology was applied to the Bellingham network in the United States, where rechlorination facilities capable of injecting chlorine concentrations ranging from 0.5 mg/L to 1.0 mg/L were considered. Results indicated that without rechlorination facilities, the Average risk was 0.0154. However, installing rechlorination facilities and injecting chlorine at a concentration of 1.0 mg/L could reduce the Average risk to 39.1%. It was observed that excessive chlorine injection through rechlorination facilities reduced water quality resilience. Consequently, a rechlorination facility with a concentration of 0.5 mg/L was selected, resulting in a reduction of approximately 20% in average risk. This study provides insights for designing rechlorination facilities to enhance preparedness against potential virus ingress in the future.

Integrated Automatic Salinity Monitoring System for the Reclaimed Land of Estuary With WCDMA (WCDMA를 이용한 간척지 하구의 염분 통합모니터링 시스템)

  • Jeong, Da-Woon;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.310-313
    • /
    • 2012
  • Recently, Land reclamation created agricultural land which is farming. Agricultural land which is farming have accident with frequency it is damage to crop of from brine. So, desalinization is the first priority prerequisite task in using the in reclaimed farm land. Vibrant research and technical development is working for reclaimed of desaliaization. But, Current technology is impossible desalinization of reclaimed land. As fast almost of people don't worry about concentration of salt in using the land reclamation of agricultural land irrigation water and river mouth of fountainhead of efforting from freshwater lake also ebb and flow of the tide land reclamation of agricultural land influnce from an increase of salt concentration by weather conditions and a malfunction of sea dike sluice In this paper, current is increased salt concentration in real time graphs were implemented to utilize external servers in using the WCDMA module. Inaddition it have to operate alarm in increase of salt concentration. besides, this program have implemented realtime concentration of salt monitoring system which save date in realtime the user can check again.

  • PDF

Assessment Method of Effective Data for Duplex TPMS Communications (TPMS 양방향 통신을 위한 유효 데이터 판정기법)

  • Kim, Seong-Min;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.499-505
    • /
    • 2012
  • TPMS(Tire Pressure Monitoring System) using the wireless communication technique is defined as the safety aid system to efficiently realize and manage the condition of tires in the vehicle. The wireless communication system of TPMS should suffers from various noise and interferences such as signals of each tire sensor or outside electrical equipments. In order to retain the data reliability of TPMS, we propose an assessment method of the data reliability based on signal-to-interference and noise ratio (SINR) of the received signal. The proposed technique can be widely applied to wireless duplex communication systems based on various sensors. We verify critical SINR values to satisfy data reliabilities of 95%, 97%, and 99% through computer simulation.

Suggestion of Secure Driver Authentication and Vehicle Control System based on NFC Communication and Biometric Information (보안성을 갖춘 NFC 통신 및 생체정보 기반의 운전자 인증 및 차량 제어 시스템 제안)

  • Park, Tae-hwan;Seo, Hwa-joeng;Lim, Ji-hwan;Kim, Ho-won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.4
    • /
    • pp.700-707
    • /
    • 2018
  • Vehicles are used in daily life as convenient transport, it is important to authenticate driver because vehicles are controlled by driver. Especially, in these days, there is a discussion on introduction of Driving Under the Influence car-starting locking device installation for preventing accidents caused by Driving Under the Influence of alcohol, these car-starting locking device installation requires a lot of money and time. Suitable user authentication for solving user's inconvenience during the disabled and men of national merit to receive discount benefits is needed. In this paper, For solving these problems, we propose the efficient vehicle control and user authentication system for preventing driving under the influence and providing the disabled and men of national merit benefit based on driver authentication by using user's smartphone NFC communication and user's biometric information.

Breakdown Characteristics of Mixtures of $SF_6$ and Dry air under Uniform and Nonuniform Electric Field ($SF_6$와 Dry air가 혼합된 가스의 평등/불평등 전계에 의한 절연파괴특성 연구)

  • Lee, Sang-Hwa;Jung, Hyun-Jae;Jeong, Seung-Young;Ryu, Cheol-Hwi;Bang, Hang-Kwon;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1502-1504
    • /
    • 2006
  • 본 연구는 $SF_6$와 Dry-air(건조공기)가 혼합된 절연매체의 절연 특성과 부분방전 특성 연구를 위하여 기초실험용 쳄버와 70kV급 GIS mock up 을 이용하여 교류전압을 인가하여 실험이 수행되었다. 전자의 경우, Sphere gap 및 Needle/Plate 전극시스템을 이용하여 순수 $SF_6$가스와 Dry-air의 절연내력을 비교하고, 챔버의 압력을 5기압으로 유지한 상태에서 Dry-air와 $SF_6$가스의 혼합비를 변화시키면서 절연내력이 측정되었다. 후자의 경우, 기초실험에서 도출된 $SF_6$가스와 Dry-air의 최적의 혼합비율을 선택한 후, 방전 개시전압과 부분방전 양상을 순수 $SF_6$가스의 결과와 비교 분석하기 위한 실험을 수행하였다. 이를 위하여 GIS 사고의 주요원인이 되는 결함들, 즉 Protrusion, Floating, Free moving particle 들을 인위적으로 모의하여 Mock up 내부에 설치하고 내부 압력을 5기압으로 유지한 상태에서 수행되었다. 전자의 경우, $0.5{\sim}5$ 기압 범위내 에서 Dry-air 압력을 변화시켰을 때 절연내력은 전극시스템에 무관하게 순수 $SF_6$가스의 결과치의 $40{\sim}50%$정도이다. 또한 챔버 압력이 5기압일 경우, Needle/Plate 전극을 이용했을 경우, Dry-air 가 80% 혼합된 절연매체는 순수 $SF_6$가스 절연내력의 80%정도이다. 후자의 경우, 인가전압을 고정 시켰을 때, 부분방전 패턴과 방전크기는, 순수 $SF_6$가스와 Dry-air 가 80% 혼합된 절연매체는 동일한 패턴과 방전크기를 나타내고 있다. 이러한 결과를 근거로, 가스 압력이 5기압에서 운전되는 전력기기의 절연 매체로서 혼합가스를 사용할 경우, $SF_6$가스와 Dry-air의 혼합비는 2:8정도가 적절한 것으로 제안한다.

  • PDF

Comparison of RSS Safety Distance for Safe Vehicle Following of Autonomous Vehicles (자율주행자동차의 안전한 차량 추종을 위한 RSS 모형의 안전거리 비교)

  • Park, Sungho;Park, Sangmin;Hong, YunSeog;Ryu, Seungkyu;Yun, Ilsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.6
    • /
    • pp.84-95
    • /
    • 2018
  • A mathematical model of responsibility-sensitive safety (RSS) has been proposed as a way to determine whether an autonomous driving accident has occurred. Autonomous vehicles related industry and academia have shown great interest in this model. However, this mathematical model lacks a comprehensive review on whether the model can be used to clarify responsibilities of autonomous vehicles in the event of a traffic accident. In this study, we analyzed the issues that need to be solved in order to apply the RSS model. In conclusion, there is a limit in the equation and the social acceptability of the RSS model. To use the RSS model practically, it is necessary to define the response time of the autonomous vehicle and to measure and control the reaction time value according to the appropriate technology level for each autonomous vehicle.

Development of S-SLA based on the Analyses of Security Functions for Anti-virus System (안티바이러스 시스템 보안기능 분석을 통한 보안SLA 등급화 지표 개발)

  • Yi, Wan-Suck;Lee, Dong-Bum;Won, Dong-Ho;Kwak, Jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.6
    • /
    • pp.237-249
    • /
    • 2010
  • If one analyzes recent cyber incidents including personal information infringement cases, it seems like actual attack is targeting Internet service providers but actually they are targeting Internet service users. For many users, all the services were not provided to them as they have signed for in the contract or personal informations, which users have provided to service providers when signing contracts, were disclosed to public without users' consent causing aftereffect. As a result, importance of S-SLA indexes, which is to be included in the SLA to be signed between a user and a service provider, is ever more increasing. Especially, if there is a S-SLA indexes for anti-virus services, service providers have to provide a high quality of service as they have signed in the SLA. However, there wasn't any researches in the S-SLA area domestically and there are only limited SLA indexes related to system or service maintenances at the moment. Therefore, this paper analyses security functions in anti-virus services and proposes S-SLA indexes for different security level.