• Title/Summary/Keyword: 시스템비상전원

Search Result 61, Processing Time 0.031 seconds

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

A Study on the Static Var Compensator Application for the train garage in Korean National Railroad: Analysis of Harmonic Generation of SVC (전동차 사무소의 SVC 적용에 따른 고조파 발생에 관한 연구)

  • Lee, Seung-Hyuk;Lee, Jun-Kyong;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.101-108
    • /
    • 2004
  • AC electric railroad system receives its power from 3-phase transmission system, Since, trainloads are changing continuously, the voltages for the single-phase load fluctuate in the train garage, and moreover, the fluctuating voltages generate high-order harmonics. This means that there is the difficulty in maintaining power quality in the power system. Therefore, a Static Var Compensator(SVC), which in general compensates the reactive power, is used in order to balance the trainload. In this paper, PSCAD/EMTDC is used for the analysis of harmonic generation in the train garage using SVC. The Total Harmonic Distortion(THD) of voltages is calculated using PSCAD/EMTDC dynamic simulation. As a result, the train garage using SVC improves power quality.

A study on Parallel running Hydroelectric power Generation breakdown through Reactive Current (무효횡류에 의한 병렬 운전 수력발전소 고장에 관한 연구)

  • Ha, Sung-Jong;Kim, Ji-Chan;Ahn, Jae-Hu;Byeon, Gyu-Yong;Pi, In-Seop;Ye, Cheol-Hae;Jeong, Ho-Un
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.214-215
    • /
    • 2011
  • 2대의 교류발전기 G1과 G2가 병렬운전 중 일 때 내부 기전력 E1, E2는 같은 위상이지만, 크기가 E1>E2로 될 때 두 발전기 사이에는 전위차가 있으므로 횡류 Ic가 흐르게 된다. 남강수력발전소는 주변압기(15MVA, 3.45/66kV) 한대에 수차발전기(7MVA) 2대가 병렬로 운전 중인데, 남강수력 제1호 수차발전기 AVR 시스템의 고장(RS 1기판)으로 G1 발전기의 내부 유기전압과 G2 발전기의 내부 유기전압에 차가 생기고, 이 양자의 차 전압을 전원으로 하여 발전기 G1과 G2를 환류하는 전류가 발생하여 발전 기동 중 비상정지 하였다. 본 논문에서는 고장원인 분석과정 및 AVR 시스템 보수 전 후 파형 비교 및 사고원인을 논하고자 한다.

  • PDF

A Study on Standardization of UPS (Uninterruptible Power Supply) for Traffic Signal Controller (교통신호제어기용 무정전전원장치 용량기준 연구)

  • Ko, Kwang-Yong;Lee, Choul-Ki;Kim, Min-Sung;Heo, Nak-Won;Jeong, Jun-Ha
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.5
    • /
    • pp.1-6
    • /
    • 2012
  • Unlike the past, modern urban intersections have dramatic growth in size and utilizations. As a result, continual traffic signal control is essential. Hence the individual or regional electrical blackout may bring about uncontrollable traffic congestion. Late summer of 2011 a regional blackout brought about traffic nightmare not including time and revenue loss associated with this disaster. Due to this disaster our national police agency and other government agencies are in process of introducing an UPS (uninterruptible power supply) system into essential intersections. This study estimates the power consumption necessary to sustain at least 2 continuous hours for a standard four-legged intersection. Prototype was studied using these standards. The field experiment of prototype showed positive results and was able to meet standard guidelines set forth. Prototype tested was able to meet standards in medium to large capacity of traffic size.

The Research On the Energy Storage System Using SuperCapacitor (슈퍼커패시터를 적용한 에너지 저장시스템 설계에 관한 연구)

  • Kim, IL-Song
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.11
    • /
    • pp.215-222
    • /
    • 2018
  • In this paper, the research on the energy storage system adapting super-capacitor has been performed. The most advanced features compared to the conventional lead-acid battery systems is that it can obtain high power capability due to the super capacitor power characteristics. The suggested system can attain high power in short times and achieve high power quality improvements. The application areas are power quality improvement system, motor start power which requires high power during transient times. The energy conversion system consists of bi-directional converter and inverter and advantages of high speed, high power charging and discharging performances. The design steps for the two loop controller of the bi-directional inverter are suggested and verified by the experiment and manufacturing. The two loop controller design starts from linearized transfer function which is calculated from the state averaging model including state decoupling method. The current controller requirements are 20% overshoot and settling time and voltage controller are no overshoot and settling time which is 10 times longer than current controller. The design is verified from the step input response. The designed controllers have unity power factor characteristics and thus can improve the power quality of the grid. It also has fast response time and zero steady state error.

Standardization to ensure Interoperability and Reliability of Campus Microgrid (캠퍼스 마이크로그리드의 상호운용성 및 신뢰성 확보를 위한 표준화)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.277-282
    • /
    • 2020
  • The construction of medium-and large-sized microgrid systems by unit area, which is being promoted worldwide, is being developed and expanded in the form of efficient operation of electric grids and independent operation in preparation for power emergencies. Therefore, for the development of the domestic electricity industry, it is urgent to analyze the current status and technology of relevant international standardization, and to make international standardization of domestic standard (draft) on the matters that need to be enacted and newly established. Campus microgrid implements smart grid element technologies such as Integrated Energy Management System(EMS), Distributed Power(DG), Energy Storage System(ESS), Demand Response(DR), and Electric Vehicle(EV) in a university campus. As a system that reduces energy use and improves energy use efficiency and energy independence, standardization is established to secure interoperability and reliability of such systems.

Study of a Photovoltaic System as an Emergency Power Supply for Offshore Plant Facilities (해양플랜트 설비의 비상전원공급을 위한 태양광 발전시스템 연구)

  • Choi, Gun Hwan;Lee, Byung Ho;Jung, Rho-Taek;Shin, Kyubo
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.279-286
    • /
    • 2018
  • The use of eco-friendly energy in the offshore plant system is expanding because conventional generators are operated by fossil fuel or natural gas. Eco-friendly energy, which replaces existing power generation methods, should be capable of generating the power for lighting protection equipment, airborne fault indication, parameter measurement, and others. Most of the eco-friendly energy used in offshore plant facilities is solar and wind power. In the case of using photovoltaic power, because the structure must be constructed based as flat solar panels, it can be damaged easily by the wind. Therefore, there is a need for a new generation system composed of a spherical structure that does not require a separate structure and is less influenced by the wind. Considering these characteristics, in this study we designed, fabricated, and tested a unit that could provide the most efficient spherical photovoltaic power generation considering wind direction and wind pressure. Our test results indicated that the proposed system reduced costs because it did not require any separate structure, used eco-friendly energy, reduced carbon dioxide emissions, and expanded the proportion of eco-friendly energy use by offshore plant facilities.

Low price type inspection and monitoring system of lithium ion batteries for hybrid vessels (하이브리드 선박용 리튬 배터리의 저가형 감시시스템 구현)

  • Kwon, Hyuk-joo;Kim, Min-kwon;Lee, Sung-geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.28-33
    • /
    • 2016
  • Batteries are used for main power engine in the fields such as mobiles, electric vehicles and unmanned submarines, for starter and lamp driver in general automotive, for emergency electric source in ship. These days, lead-acid and the lithium ion batteries are increasingly used in the fields of the secondary battery, and the lead-acid battery has a low price and safety comparatively, The lithium ion battery has a high energy density, excellent output characteristics and long life, whereas it has the risk of explosion by reacting with moisture in the air. But Recently, due to the development of waterproof, fireproof, dustproof technology, lithium batteries are widely used, particularly, because their usages are getting wider enough to be used as a power source for hybrid ship and electric propulsion ship, it is necessary to manage more strictly. Hybrid ship has power supply units connected to the packets to produce more than 500kWh large power source, and therefore, A number of the communication modules and wires need to implement the wire inspection and monitor system(WIIMS) that allows monitoring server to transmit detecting voltage, current and temperature data, which is required for the management of the batteries. This paper implements a low price type wireless inspection and monitoring system(WILIMS) of the lithium ion battery for hybrid vessels using BLE wireless communication modules and power line modem( PLM), which have the advantages of low price, no electric lines compared to serial communication inspection systems(SCIS). There are state of charge(SOC), state of health(SOH) in inspection parts of batteries, and proposed system will be able to prevent safety accidents because it allows us to predict life time and make a preventive maintenance by checking them at regular intervals.

Cellular Automata Simulation System for Emergency Response to the Dispersion of Accidental Chemical Releases (사고로 인한 유해화학물질 누출확산의 대응을 위한 Cellular Automata기반의 시뮬레이션 시스템)

  • Shin, Insup Paul;Kim, Chang Won;Kwak, Dongho;Yoon, En Sup;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • Cellular automata have been applied to simulations in many fields such as astrophysics, social phenomena, fire spread, and evacuation. Using cellular automata, this study develops a model for consequence analysis of the dispersion of hazardous chemicals, which is required for risk assessments of and emergency responses for frequent chemical accidents. Unlike in cases of detailed plant safety design, real-time accident responses require fast and iterative calculations to reduce the uncertainty of the distribution of damage within the affected area. EPA ALOHA and KORA of National Institute of Chemical Safety have been popular choices for these analyses. However, this study proposes an initiative to supplement the model and code continuously and is different in its development of free software, specialized for small and medium enterprises. Compared to the full-scale computational fluid dynamics (CFD), which requires large amounts of computation time, the relative accuracy loss is compromised, and the convenience of the general user is improved. Using Python open-source libraries as well as meteorological information linkage, it is made possible to expand and update the functions continuously. Users can easily obtain the results by simply inputting the layout of the plant and the materials used. Accuracy is verified against full-scale CFD simulations, and it will be distributed as open source software, supporting GPU-accelerated computing for fast computation.

A Study on Effect of B/L's Exemption Clauses Relating to the Governing Law of English Law (영국법의 준거법과 관련한 선하증권 면책약관의 효력에 관한 연구)

  • Han, Nak-Hyun;Jung, Jun-Sik
    • Journal of Korea Port Economic Association
    • /
    • v.22 no.4
    • /
    • pp.1-17
    • /
    • 2006
  • In the Bill of Lading of The Irbenskiy Proliv is not subject to the Hague-Visby Rules in accordance with paragraphs (A) and/or (E) of cl.1 or to the Hague Rules in accordance with paragraphs (B) and/or (D) of cl.1. The Irbenskiy Proliv is very rare case that is effective to exempt the carrier as literal words of Bill of Lading. The action concerns cargoes of perishable goods shipped from Brazil to Japan, under Bills of Lading each of which contained an extensive carrier's exemption clause. A preliminary issue was ordered to be determined on the question whether c1.4 is effective to exempt the ralliers from any potential liability for the claims in this case. The court held that there is no reason to reject c1.4 as part of each of the contracts contained in or evidenced by the bills of lading; and it protects the carrier where damage to the goods shipped results from such causes. It is therefore effective to exempt the carriers from any potential liability for those claims.

  • PDF