• Title/Summary/Keyword: 시설 설계

Search Result 3,149, Processing Time 0.039 seconds

The Case Study on Performance Measurement Weighting for Efficient Value Engineering Study of Sewage Treatment Facliity (하수처리시설의 효율적인 VE수행을 위한 다단계성능평가 분석)

  • Kim, Dongjin;Park, Jaeil;Lee, Jaehun;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.1
    • /
    • pp.40-47
    • /
    • 2016
  • Recently, the demand of sewage treatment facilities have increased by growing the population growth of city and industrialization. However, most of public sewage treatment facilities lack the preparations of design criteria by increasing sewage water amount in the future. In order to respond to this situation, the government has consistently promoted the sewage treatment construction project. This study conducted a survey targeting residents and sewage treatment facilities, civil engineering a VE project professionals for effectively operating the sewage treatment facilities and improving its value to be built in the future. Based on this survey, this study will introduce the list of performance measurements which can not only save cost but also reflect opinion of users and residents. In addition, using Multi-Level Performance Measurement and AHP analyzed the weights of performance measurement which is more objective than existing things for applying efficient VE process

A Study on Assesment of Aalidity of Introducing of Design·Construction·Supervision Register Criteria Measures for Hazardous Materials Facilities (위험물시설의 설계·시공·감리업 등록제 도입에 대한 타당성 검토에 관한 연구)

  • Cha, Jung-Min;Lee, Yong-Jae;Kim, In-Beom;Hyun, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.27-37
    • /
    • 2015
  • This study is to analyze current inadequate status of installing hazardous materials facilities, and to propose rational standards by researching validity for implementing registration for design, construction, supervision for installing fire safety facilities. By studying installation of registering designing, constructing, supervising industry on hazardous material facilities, professional and higher level of stability measures for national hazardous material facility was provided. For above reasons, necessity of institutionalizing of registering standards for construction and supervising industry became clear. Much more gradual institutionalization is needed for construction industry. Moreover, new national qualification should be reconsidered, in order to rebuttal the above and also to cultivate and acquire technical power.

Design and construction of verification complex that checks the efficiency on water permeability of permeable pavement parking lot LID (투수 주차장형 LID 투수효율성 검증실험단지 설계 및 구축)

  • Lee, Eun Ku;Shin, Hyun Shuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.317-317
    • /
    • 2016
  • 저영향개발(Low Impact Development, LID) 시설들은 미국 일본 등 선진국을 중심으로 관련법에 따라 개발 및 적용 되어왔으나 국내에서는 최근에서야 LID 시설을 적용할 수 있는 제도적인 틀을 구축하고 있는 실정이며, 국내 여건에 맞는 LID 시설을 개발하여 그 효용성을 검증하기 까지는 상당한 시간이 소요될 것으로 판단된다. 서울시는 2014년 '서울특별시 빗물관리에 관한 조례 전부개정조례'를 발표함으로써 한국형 LID 시설을 대단위로 적용 하고 검증 할 수 있는 발판을 마련하였다. 서울시의 2014년 전부개정조례에 따르면 시장 및 구청장은 저영향개발 계획 수립의 실효성 확보를 위하여 저영항개발 사전협의 제도를 마련하여 시행하여야 하며, 시장은 저영향개발 지구단위계획을 수립하여야 한다. 이에 따라, 본 연구에서는 실제로 적용 가능한 투수포장 주차장을 설계 할 수 있도록 투수 주차장형 LID 시설을 검증할 수 있는 투수효율성 검증실험단지를 설계 및 구축 하였다. 과거 도심의 우수배제는 중앙 집중형 시스템으로 단기간에 우수를 차집하여 배제하는 방식이었으나, 근래에는 집중형 우수배제 시스템의 위험성, 경제성 그리고 용량한계 등 여러 가지 문제점이 부각되면서 분산형 시스템으로의 전환이 이루어지고 있다. 물순환도시 및 지속가능한 도시 등이 분산형 우수배제 시스템의 예이며, 주차장, 도로, 건물 등 불투수 표면으로부터의 우수를 지면으로 침투 및 침루시키는 방법 등을 활용하여 건전한 물순환을 꾀하고 있다. 침투 및 침루 능력은 각각 포장체 및 포장면 하부구조의 재료와 밀접한 관련이 있으며 재료의 선정은 하부구조의 안정성 확보를 고려하여 선택되어야 한다. 또한 우수 배제를 위한 유공관은 접합점에서 강도를 유지하면서 효율적으로 유수를 배제할 수 있어야 하며, 저류조 설치는 강수의 활용목적에 맞게 선정되어야 한다. 이러한 투수 주차장형 LID 시설은 하나의 시스템으로서 포장체의 재료에 따른 공학적 성질, 하부구조 구축방법 및 재료 선정 그리고 유공관 배열 등에 따라 그 시스템의 거동이 변화하므로 기존에 행해왔던 단순 재료실험으로는 투수성 주차장의 우수배제 시스템을 평가할 수 없다. 따라서 본 연구에서는 이를 검증할 수 있는 투수효율성 검증실험단지 설계 및 구축하였다.

  • PDF

A Estimation and Analysis of Characteristics for Hazen-Williams C Value of Water Pipe System (상수관로 유속계수 산정 및 특성 분석)

  • Kim, Kyoung Oh;Kim, Se Min;Park, Yung Ki
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.239-239
    • /
    • 2019
  • 상수도시설 중 배수관망시설은 해당 지역의 영향을 민감하게 받는 시설이므로 설계시 해당시설의 특성을 충분히 고려해야 한다. 배수시설은 설치된 해당지역에 따라 그 특성이 매우 다르기 때문에, 설계지표 또한 해당 도시마다 다르게 설정될 수 있다. 도시의 규모가 크거나, 그 특성이 해당 구역에 따라 다른 경우에는 같은 도시의 경우라도 대상구역에 따라 다른 지표를 사용하는 경우도 있다. 따라서 이런 상수도관망의 설계 및 관리를 위해서는 장기간 현장여건에 맞는 관측자료를 통한 정밀한 수리분석이 요구되며 국내의 경우 일반적으로 Hazen-Williams 공식을 사용하고, 이때 관내면의 마찰손실계수 C는 유속계수라 한다. 이러한 유속계수는 상수관로의 물리적 특성을 나타내며 관로 내의 흐름해석, 펌프 및 관로의 설계, 최적 운영 방안, 통수능력 및 관 노후도 평가 등에 사용되거나 영향을 미치는 중요한 요소라 평가되고 있다. 또한 다수의 현장 관측 자료를 확보하여도 분기 구간과 펌프 및 밸브 등으로 인한 손실 등의 오차가 발생하므로 유속계수 산정 시 발생되는 많은 오차들을 줄여 보다 신뢰성 있는 유속계수를 산정해야 하고, 현장 관측 자료를 이용하여 유속계수를 산정하기 어려운 구간에 대해서는 관망해석 모델링을 통하여 결정하고 있다. 본 연구에서는 전주권 광역상수도의 계통 특성에 맞는 관로의 유속계수를 결정하기 위해 관리주체에서 기존에 설치한 수압계와 유량계 및 관망도를 이용하여 기초자료를 수집하고 Hazen-Williams 공식을 이용하여 유속계수를 산정하였다. 계산된 상수관로 유속계수는 전주시의 10개 계통에서 최소 107.06, 최대 145.02, 평균 127로 계산되었으며, 유속계수에 영향을 미치는 물리적 요소들의 관계를 파악하고자 상관성 분석 실행하였다. 그 결과 관경과 경과년수의 상관계수 R은 0.011 관경과 유속계수의 상관계수는 -0.009로 두변수간의 상관성이 거의 없고, 경과년수와 유속계수의 상관계수는 -0.776로 음의 상관성을 갖는 것으로 분석되었다. 이와 같이 제시한 유속계수는 해당 지역의 참고자료나 기준으로서 활용할 수 있을 것으로 판단되며 비 대상 지역에서도 현장자료가 부족한 곳의 유속계수를 산정할 경우 보다 신뢰성 있게 유속계수를 산정할 수 있는 방법을 제시하고자 한다.

  • PDF

Analysis of area-based optimal capacity design method in vegetation type LID (식생형 LID 시설에서 면적 기반의 적정 용량 설계 방법 연구)

  • Park, Seowon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.383-389
    • /
    • 2018
  • Recently, it has been reported that water pollution due to non-point pollutants continues. Studies have been actively carried out to prevent such non-point pollutants from flowing into the water system and to prevent water pollution. In this study, to evaluate the adequate design of the LID facilities the rainfall corresponding to 80% of the cumulative rainfall of Yongin city was applied to an SA / CA graph obtained from the analysis of monitoring results of the vegetation type LID facility. As a result, the appropriate SA/CA ratio was 0.6% for stormwater sustain efficiency 80% and the appropriate SA/CA ratio was 0.5% for TSS removal efficiency 80%. The appropriate SA/CA ratio of the vegetation type LID proposed in this study can be used as a basis. for the future vegetation type LID design. If more data of vegetation type LID are added through continuous research, it will be more accurate.

Study on the Operation and Status of Private Sewage Treatment Facilities (개인하수처리시설 운영 및 실태 연구)

  • Lee, Jang-Hown;SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.2
    • /
    • pp.31-40
    • /
    • 2020
  • As private sewage treatment facilities in Korea are constantly concerned about the distribution and poor construction of defective products, minimum standards for each unit process applicable to the planning and design of sewage treatment facilities are deemed necessary. The problems and requirements of the analysis results of the operation status discussed in this study are as follows. 1) Strengthening education of supervisor of private sewage treatment facility. 2) Poor operation and management of Sewage treatment facilities. 3) A mandatory review of sewage treatment facilities for less than 2 ㎥/day of facilities other than sewage treatment zones. 4) Necessity of management of sewage treatment facility in feedstocks. 5) As a result of the technical review, Improvement plans for Ineligible facility are needed. It is also necessary to prepare a guidebook for design construction and maintenance by investigating and analyzing guidelines and data related to domestic and foreign private sewage treatment facilities.

Study on the Applicability of Standard Design Response Spectrum Analysis Method for Pile-type Mooring Facilities (말뚝식 계류시설의 표준설계응답스펙트럼 해석법 적용성 연구)

  • Oh, Jeong-Keun;Jeong, Yeong-Seok;Kwon, Min-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.27-36
    • /
    • 2020
  • The purpose of this paper is to study on the applicability of the standard design response spectrum from the response spectrum analysis method, mainly applied to pile mooring facilities. To this end, after performing the ProShake 1-dimensional site response considering various geological conditions, the current standard design response spectrum was compared, and the ground-pile model in time history and two-dimensional site response analysis using Abaqus were performed to analyze the dynamic behavior of the ground-pile and to examine the selection method of the reference surface of the response spectrum on the installed slope, respectively. As a result, it was confirmed that no problems were found in the applicability of the current standard design response spectrum and no improvements are needed as well when considering the characteristics of the ground-pile dynamic behavior and the slope of the pile mooring facility.

Seismic Behavior Characteristics of Spherical Storage Tanks Supported by Inelastic Members and Performance-Based Seismic Design Based on Reliability (비선형지지구조 저장탱크의 지진거동 특성과 신뢰도 기반의 성능기반 내진설계)

  • Jang jeong min;Sun chang ho;Kim ick hyun;Choi jeong in
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.27-33
    • /
    • 2023
  • In a petrochemical plant, various mechanical equipments and structures are interconnected to ensure operability. Since the production activities of petrochemical plants have a great impact on the national economy, it is very important to maintain not only structural safety but also the operability of the facilities. However, the current seismic design standards present the design requirements of facilities mainly aimed at preventing collapse, and do not provide the requirements for securing operability of facilities. Depending on the behavioral characteristics of the facility, operability of the facility can be secured by seismic performance levels other than the collapse prevention level, so it is necessary to present seismic design methods that can apply various seismic performance levels. Spherical (ball) storage tanks are supported by columns and braces and exhibit complex nonlinear behavior because of buckling and yielding of support members. In this study, nonlinear seismic behavior characteristics were statistically analyzed and a new performance-based seismic design method was proposed based on them.

A Study on the Noise and Vibration Reduction at Supports Center on a Tall Building Apartment (초고층 빌딩의 헬스장 구조소음 및 진동 대책)

  • 박해동;백재호;이홍기;전종균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.527-532
    • /
    • 2003
  • 아파트의 층간소음저감을 위한 다양한 기술이 개발되고 있다. 콘크리트 건물의 단일층을 경계로 한 소음저감을 위한 공기음의 투과손실을 증가하는 방법이 주로 적용되고 있으나, 철골조 초고층아파트 스포츠 시설 운영시 이에 대한 대책으로 공기음의 대책과 구조음의 대책을 두단계에 걸쳐 수립하였다. 초고층 아파트 내부에 스포츠 시설의 배치는 이를 이용하는 사용자에게 편리성의 주지만 철골조의 특성상 충격성 진동원이 발생하는 스포츠 시설은 상하부층인 아파트에 소음진동의 연향으로 인해 이를 방지하는 설계가 요구된다. 일반적인 아파트의 충간 소음진동문제는 이를 발생시키는 상부거주자의 예절과 충간 소음진동 저감 기술이지만 아파트내부의 동일층을 경계로 위치한 스포츠 시설은 시설의 사용성에 반해 하부층에 미치는 영향을 기술적으로 저감하여야 한다. 입주한 초고층아파트의 스포츠 시설에서 발생하는 소음진동 민원문제를 풀기 위하여, 하부층 민원인이 느끼지 못하는 수준의 소음과 진동 허용치를 상호 결정하고 이를 만족하기 위한 차음 및 구조소음 설계를 수행한 사례이다.

  • PDF