• Title/Summary/Keyword: 시공조건

Search Result 1,434, Processing Time 0.028 seconds

Installtion of Solar Hot Water Heater (태양열온수기 시공설치)

  • Lee, Sung-Soo
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.51-67
    • /
    • 1998
  • In this paper, various solar systems are introduced according to usage pattern considering national weather condition and hot water comsumption pattern. First, basic principle and components of solar hot heater are presented, and then operational machanism of various solar hot water systems are presented according to the case of domestic and industrial use with network of piping.

  • PDF

원전 지하 Box Culvert의 효율적 관리를 위한 자동화 설계시스템 개발

  • 송영철;조명석;방기성;우상균
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.891-896
    • /
    • 1998
  • 최근 도시의 기능이 날로 다양화되고 복잡해짐에 따라 지하공간에 대한 활용도가 대단히 높아지고 있으며, 한국전력공사에서도 원자력 발전소에 많은 전력구조물을 지하에 건설하고 있다. 이러한 지하구조물을 보다 효율적이고 신속하게 유지관리하기 위해서는 지하 구조물의 구조설계 및 도면제작을 자동으로 수행할 수 있는 시스템의 개발이 필수적이다. 이에 따라 한국전력공사 전력 연구원에서는 기존의 설계도면 및 정보에 쉽게 접근할 수 있으며, 구조설계에서부터 도면제작에 이르는 과정을 일괄 처리할 수 있는 “Box 구조물 자동화 설계 시스템”을 개발하여 실무에 적용하고 있다. 본 시스템의 개발은 지하구조물의 계획, 설계, 시공조건 등의 변경에 신속하게 대처할 수 있으므로 설계업무의 효율성을 극대화함은 물론 생산성의 향상, 품질의 고급화 및 설계자료 유지관리의 선진화에 크게 기여할 것으로 사료된다.

  • PDF

The Head Condition and the Installation Position of Micro-Pile to Reduce the Settlement of Adjacent Structures in Sandy Ground Tunnelling (터널 굴착시 인접구조물의 침하억제를 위한 마이크로파일의 두부조건 및 설치영역에 따른 효과)

  • 임종철;박이근;오명렬
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.61-70
    • /
    • 2001
  • 도심지에서의 터널은 주로 얕은 토층비에서 이루어진다. 따라서, 본 연구에서는 토층비 1, 2 정도의 얕은 터널에 대한 터널시공을 고려하였다. 또한, 도심지 얕은 터널에서 겪게 되는 어려움 중 하나인 지상구조물의 손상을 방지하는 것이다. 이러한 경우, 구조물의 손상을 방지하기 위해 소형장비로 간단하고 저렴한 시공이 가능한 마이크로 파일공법의 채택이 주목을 받고 있다. 본 연구에서는 마이크로 파일의 설치위치와 설치각도 및 두부 고정도를 달리한 실험을 실시하여 토압 및 지표면 침하를 중심으로 그 영향을 평가하였다. 마이크로 파일의 설치위치에 있어서 거리비(A/L$_{p}$) 0.5 이내에서 침하감소면에서 대략 22%~37% 정도의 효과가 있었으며, 마이크로 파일의 두부는 파일간 서로 결속하는 것이 더 효과적임을 알 수 있었다. 이러한 경향은 토압분포에서도 마찬가지이다.다.

  • PDF

A study on the characteristic and designing condition of Curtain wall (Curtain Wall의 특성 및 설계조건에 관한 연구)

  • Jeong, Eul-Gyu;Im, Chil-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.125-131
    • /
    • 2004
  • Nowadays, it seems we are in the high time of construction design because development of construction technology widen the option of construction exterior closing materials and deepen the high-tech construction method with all various materials. When we see the flow of construction market, the mainstream is the high-rise intelligent building, which makes the best use of the small midtown area efficently. Therefore, Alum curtain wall is becoming the main material of exterior construction, the concept of which is changing from just a simple window frame to an outer wall which has comprehensive function and capability. As we think of the importance of Curtain wall as a comprehensive outer wall, We should do thorough technical examination and verification at the stage of construction design and plan of carrying out construction.

Evaluation on Vapor Pressure of Ultra-high-strength Concrete by Heating Condition (가열조건에 따른 초고강도 콘크리트의 내부수증기압력 평가)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Yoon, Min-Ho;Lee, Bo-Kyeong;Seo, Won-woo;Baek, Jae-Uk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.224-225
    • /
    • 2017
  • Ultra-high-strength concrete exposed to high temperature is likely to cause spalling. Spalling is caused by the vapor pressure of the concrete, and the vapor pressure may be different depending on the heating conditions of the concrete. Therefore, in this study, a ring-type restrained specimen was fabricated using ultra-high-strength concrete and the vapor pressure generated in the concrete by heating condition(rapid and slow heating) was evaluated.

  • PDF

Strain Behavior of Ultra-high-strength Concrete under High Temperature and Loading (고온 및 재하에 따른 초고강도콘크리트의 변형거동)

  • Kim, Gyu-Yong;Nam, Jeong-Soo;Choe, Gyeong-Cheol;Yoon, Min-Ho;Hwang, Eui-Chul;Baek, Jae-Uk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.86-87
    • /
    • 2017
  • The high-temperature creep of Ultra-High-Strength Concrete (UHSC) has been investigated in this study. The purpose of this study is to evaluated total strain and high-temperature creep at elevated temperatures under loading condition of UHSC. As results, Total strain of UHSC increased showing shrinkage with increasing compressive strength. The high-temperature creep of UHSC increased with the temperature and higher level of compressive strength showed bigger high-temperature creep.

  • PDF

Cracking Behavior of Cement and Concrete Damaged by High Temperature of 800℃ (800℃ 조건에서의 시멘트 경화체의 균열 특성)

  • Ji, Woo-Ram;Park, Ji Woong;Shin, Ki Don;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.26-27
    • /
    • 2017
  • In this study, the cracking characteristics of cured pastes at 800℃ were investigated by X-ray CT. The test specimens were fabricated with and without aggregate, and the heating rate condition was applied at rapid heating (10.0℃/min). It is considered that the rapid heating condition does not cause a temperature gradient phenomenon because the temperature difference between the surface and the center of the sample is small due to a low heating rate unlike an actual fire. The cracking condition of the specimens without aggregate was more severe than that of specimens with aggregate.

  • PDF

Properties Adsorption According to Test Condition of Radon Adsorption-type Matrix (라돈 흡착형 경화체의 시험 조건에 따른 흡착특성)

  • Lim, Hyun-Ung;Kim, Heon-Tae;Gwon, Oh-Han;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.109-110
    • /
    • 2016
  • This study is a absorbing Radon gas to occur indoor or outdoor. As a absorbent Radon gas, making cementless abso rbent matrix that accomplish experiment. In other to accomplish this experiment, Confirming Radon gas release ratio and accurating absorption, reduction of a half-life that 3,8 days from Radon gas source, we need to decide Radon absorbent experiment method. So, we accomplish to find Radon measurement method considering properties and a half-life that 3,8 days from Radon gas source. As the experimental factors, After stabilizing of Radon gas source and so on, we accomplish the experiment that is there or not and seal of Radon source.

  • PDF

Temperature characteristics of iron and molds in summer apartment conditions (여름철 Apt현장 조건에서의 철근 및 거푸집의 온도특성)

  • Lee, Jea-Hyeon;Moon, Byeong-Yong;Lee, Sang-Un;Lee, Joung-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.17-18
    • /
    • 2016
  • On apartment construction sites in hot weather environments, the high temperature of 30℃ and above and radiation from the sun cause iron and mold temperatures to rise, which lowers worker efficiency and has a negative effect on the deposited concrete. Therefore this study measured the temperature of D10 ~ D16 iron and aluminum items actually used on box frame apartment construction sites currently under construction, in order to give reference information to solve hot weather concrete problems. The temperature measurement results showed that for iron, temperatures rose to around 45℃, and for mold around 58.8℃, calling for safety measures for workers in case of possible burning and other problems.

  • PDF

Self-Healing Investigation of Bisphenol F-Type Epoxy-Modified Mortars with Expansive Admixtures Under Outdoor Exposure Conditions (환경조건에 따른 팽창성 혼화재 및 비스페놀 F형 에폭시수지 병용 모르타르의 자기치유 검토)

  • Park, Seung-Min;Kim, Wan-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.22-23
    • /
    • 2017
  • The purpose of this study is to ascertain self-healing function on microcracks in bisphenol F-type epoxy-modified mortars using expansive admixtures. The specimens are prepared with various polymer-binder ratios of 0, 5, 10, 20%, expansive admixture contents of 0% and 10%, a sodium carbonate content of 0.25%, and subjected to exposure conditions of CR1, CR2, CR3 and CR4. The specimens are tested for self-healing effect, porosity and FE-SEM analysis. As a result, self-healing effects of bisphenol F-type EPMMs with expansive admixtures are visible in all of the outdoor exposure conditions. In particular, exposure conditions of CR3 and CR4 are most noticeable. And the porosity of EPMMs is reduced with an increase in the polymer-binder ratio, and is considerably smaller than that of unmodified mortar.

  • PDF