The twenty one individuals with total knee replacement who were admitted to Kang-Dong Hospital for comprehensive physical therapy were studied in order to demonstrate the effectiveness of an isokinetic test program using the Cybex 6000 machine. The subjects were divided into three groups with the isometric exercise group receiving isometric exercise, the isokinetic eccentric exercise group, and isokinetic concentric exercise group receivind isokinetic exercise(eccentric, concentric) to knee flexors and extensors muscles for a six weeks' period using the Cybex 6000. The results are follow: 1. The extensors were increased significantly at all groups after 6 weeks training(p<.05). The flexors were increased significantly at isokinetic eccentric and isokinetic concentric group but no significantly differences at isometric group(p>.05) 2. At the effect of extensors and flexors after 6 weeks training. higher to 30$^{\circ}$ /sec of isokinetic concentric exercise, lower to 120$^{\circ}$ /sec of isometric exercise. 3. The peak torque was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 4. The total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 5. The ratio of peak torque to body weight were more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 6. The average power was more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 7. The average R.O.M in the pre-exercise and post-exercise was not different significantly in all three groups. According to the above results, In the muscle strength recovery for total knee replacement patients, isokinetic concentric exercise group was significantly greater than the isokinetic eccentric and isometric exercise groups after a six weeks training.
Kim, Chang-Gon;Lee, Jin-Hyun;Jo, Dong-Chan;Moon, Su-Jeong;Park, Tae-Yong;Ko, Youn-Suk;Song, Young-Sun;Lee, Jung-Han
Journal of Korean Medicine Rehabilitation
/
v.24
no.1
/
pp.111-118
/
2014
The objective of this study is to report the effectiveness of Korean medical rehabilitation for total knee replacement. Three female patients who had total knee replacement were treated by Korean medical rehabilitation with protocol. We evaluated the consequences by checking numeric rating scale (NRS), Lysholm knee score, physical examination of knee joint and walking state. After Korean medical rehabilitation, we find out that the pain and function were improved. NRS, Lysholm knee score, physical examination of knee joint, walking state of patients were also improved. Korean medical rehabilitation can be effectively used for total knee replacement patients. There is a limit that this study hasn't sufficient number of cases. Further studies are needed to set up a Korean medical rehabilitation protocol.
Yoo, Je Bog;Park, Hyun Ju;Chae, Ji Yeoun;Lee, Eun Ju;Shin, Yoo Jung;Ko, Justin Sangwook;Kim, Nam Cho
Journal of Korean Academy of Nursing
/
v.43
no.3
/
pp.352-360
/
2013
Purpose: In this study an examination was done of the effects of the American Society of PeriAnesthesia Nurses (ASPAN) Evidence-Based Clinical Practice Guidelines on body temperature, shivering, thermal discomfort, and time to achieve normothermia in patients undergoing total knee replacement arthroplasty (TKRA) under spinal anesthesia. Methods: This study was an experimental study with a randomized controlled trial design. Participants (n=60) were patients who underwent TKRA between December 2011 and March 2012. Experimental group (n=30) received active and passive warming measures as described in the ASPAN's guidelines. Control group (n=30) received traditional care. Body temperature, shivering, thermal discomfort, time to achieve normothermia were measured in both groups at 30 minute intervals. Results: Experimental group had slightly higher body temperature compared to control group (p=.002). Thermal discomfort was higher in the experimental group before surgery but higher in the control group after surgery (p=.034). It decreased after surgery (p=.041) in both groups. Time to achieve normothermia was shorter in the experimental group (p=.010). Conclusion: ASPAN's guidelines provide guidance on measuring patient body temperature at regular intervals and on individualized and differentiated hypothermia management which can be very useful in nursing care, particularly in protecting patient safety and improving quality of nursing.
The Journal of Korean Academy of Orthopedic Manual Physical Therapy
/
v.26
no.1
/
pp.1-8
/
2020
Background: The aim of this study was to conduct an Otago exercise program with total knee replacement patient (TKR) in a clinical setting and ascertain its effects on balance, walking ability and falls efficacy. Methods: The participating subjects were 30 people who had been diagnosed with TKR. They were assigned to two groups (Exp; Otago exercise and general physical therapy, n=15; Con; balance exercise and general physical therapy, n=15), and the exercises were conducted for three sessions per week for four weeks. The main balance outcomes were evaluated using the timed up and go test (TUG), while walking ability was evaluated using the 10m walk test (10MWT), direction change ability was measured using the figure 8 of walk test (F8WT), and the decrease of fear was evaluated using the modified falls efficacy scale (MFES). Results: In the analysis results, the Exp group showed significant increases in TUG, 10MWT, and F8WT within the both groups. There were significant differences in all variables between the Exp group and the Con group at the post-intervention evaluation, but there was no significant difference between the groups with respect to the TUG. Conclusion: The results of this study demonstrated that Otago exercise would be useful to improve balance and walking for TKR patients who want to improve their abilities and activities of daily living.
Background: Postoperative pain after bilateral total knee replacement (TKR) is expected to be more severe than unilateral TKR. Intravenous patient-controlled analgesia (IV PCA) is less effective than other methods of pain management especially immediately after an operation even though it is an easily controlled method for managing pain. This study was designed to evaluate the effect of femoral nerve blocks combined with IV PCA after bilateral TKR for postoperative pain control. Methods: The patients in group I (n = 20) were given only IV PCA with morphine and group II (n = 20) were given bilateral femoral nerve blocks with 12 ml of 0.25% bupivacaine and epinephrine 1 : 400,000 before extubation followed by an IV PCA. Main outcome measures included numerical rating pain score, cumulative opioid consumption, hourly dose during each time interval, and side effects. Results: The pain score in group II was significantly lower than that in group I immediately after recovery of awareness and at 3, 6, 12 hours postoperatively. Cumulative opioid consumption was significantly decreased in group II during the first 48 hours postoperatively. The hourly dose in group II was also significantly lower than that in group I until 12 hours postoperatively. There was no difference in side effects between the groups. Conclusions: We concluded that bilateral femoral nerve blocks improve analgesia and decrease morphine use during IV PCA after bilateral TKR.
Kim, Sang-Hoon;Ahn, Ok-Kyun;Bae, Dae-Kyung;Kim, Yoon-Hyuk;Kim, Kyung-Soo;Lee, Soon-Gul
Journal of Biomedical Engineering Research
/
v.28
no.1
/
pp.108-116
/
2007
Recently, it has been reported that the posterior stabilized implant, which is clinically used for the total knee replacement (TKR), may have failure risk such as wear or fracture by the contact pressure and stress on the tibial post. The purpose of this study is to investigate the influence of the mal alignment of the posterior stabilized implant on the tibial post by estimating the distributions of contact pressure and von-Mises stress on a tibial post and to analyze the failure risk of the tibial post. Finite element models of a knee joint and an implant were developed from 1mm slices of CT images and 3D CAD software, respectively. The contact pressure and the von-Mises stress applying on the implant were analyzed by the finite element analysis in the neutral alignment as well as the 8 malalignment cases (3 and 5 degrees of valgus and varus angulations, and 2 and 4 degrees of anterior and posterior tilts). Loading condition at the 40% of one whole gait cycle such as 2000N of compressive load, 25N of anterior-posterior load, and 6.5Nm of torque was applied to the TKR models. Both the maximum contact pressure and the maximum von-Mises stress were concentrated on the anterior-medial region of the tibial post regardless of the malalignment, and their magnitudes increased as the degree of the malalignment increased. From present result, it is shown that the malalignment of the implant can influence on the failure risk of the tibial post.
Park, Hyung-Kyun;Kim, Yoon-Hyuk;Park, Won-Man;Kim, Kyung-Soo
Journal of Biomedical Engineering Research
/
v.29
no.6
/
pp.451-456
/
2008
Total knee arthroplasty(TKA) using computer-assisted navigation has been increased in order to improve the accuracy of femoral and tibial components implantation. Recently, a few clinical studies have reported on the femoral stress fracture after TKA using computer-assisted navigation. The purpose of this study is to investigate the stress concentration around the femoral pin-hole for different pin-hole diameter, the modes of pin penetration by finite element analysis to understand the effects of pin-hole parameters on femoral stress fracture risk. A three-dimensional finite element model of a male femur was reconstructed from 1 mm thick computed tomography(CT) images. The bone was rigidly fixed to a 25 mm above the distal end and 1500 N of axial compressive force and 12 Nm of axial torsion were applied at the femoral head. For all cases, transcortical pin penetration mode showed the highest stress fracture risk and unicortical pin penetration mode showed the lowest stress concentration. Pin-hole diameter increased the stress concentration, but pin number did not increase the stress dramatically. The results of this study provided a biomechanical guideline for pin-hole fracture risk of the computer navigated TKA.
Background: The purpose of this study was to compare the analgesic effect of 0.25% and 0.5% levobupivacaine for real time ultrasound guided single-injection femoral nerve block for the patients who are undergoing bilateral total knee arthroplasty (TKA). Methods: Femoral nerve block was done to all patients with 20 ml of 0.9% normal saline on one leg and 20 ml of 0.25% levobupivacaine on the other leg for group I (n = 16) and 0.5% levobupivacaine for group II (n = 15) with 1:200,000 epinephrine and using real-time ultrasound and a nerve stimulator. The data concerning the verbal numerical rating scale (VNRS) for each leg, the consumption of the intravenous patient-controlled analgesia (IV PCA) and the demands for the additional analgesics was collected at 0, 1, 6, 12, 24 and 48 hours after the operation. Results: The legs on which femoral nerve block was done with levobupivacaine showed a lower VNRS score than the legs with normal saline in either group I or group II. The VNRS scores between the two legs, the consumption of the IV PCA and the demand for additional analgesics showed no significant differences between the groups. Conclusions: Our results demonstrate that single-injection femoral nerve block using real-time ultrasound with either 0.25% levobupivacaine or 0.5% levobupivacaine 20 ml provides a good effect for the postoperative pain control after TKA.
Purpose: Patient-controlled epidural analgesia (PCEA) is an effective method for controlling post surgical pain. However, it is associated with adverse drug reactions such as nausea and vomiting. In this, study we tested the effects of Nei-Guan (P6) acupressure on PCEA-associated nausea, vomiting, and pain in geriatric patients after total knee replacement arthroplasty (TKRA). Methods: Ninety-nine patients who had TKRA for the first time were randomly assigned to either, experiment group (n=50) or control groups (n=49). All patients received PCEA immediately after surgery, but acupressure on Nei-Guan (P6) point was applied to experiment group only. Ten minutes of finger acupressure on Nei-Guan (P6) acupressure point was applied twice with 15 minute-interval in the experiment group. The incidence of nausea, vomiting, and retching as well as pain intensity were assessed at 12 and 24 hours after surgery. Nausea, and vomiting were assessed by Index of Nausea, Vomiting and Retching (INVR) questionnaire. Pain intensity was measured with frequency of analgesics. Results: Vomiting both was significantly different between two groups at 12 hours (t=-2.18, p=0.03) and 24 hours (t=-2.64, p=0.01) after surgery. Total scores of nausea, vomiting and retching in experimental group was significantly lower than control group 24hours after surgery (t=-2.18, p=0.03). However, pain was not different between two groups. Conclusion: Nei-Guan (P6) acupressure may be considered as an effective nursing intervention to decrease PCEA-associated nausea and vomiting in older patients after TKRA.
The Journal of Korean Academy of Orthopedic Manual Physical Therapy
/
v.24
no.1
/
pp.77-83
/
2018
Background: The purpose of this study is to investigate that effect of manual therapy using pelvic compression belt on hip abductor strength and balance ability in total knee replacement (TKR) patients. Methods: The subjects consisted of twenty two post-TKR patients. Participants were randomly assigned to a pelvic belt group (n=11) and a placebo group (n=11). All participants underwent manual therapy including range of motion exercise, soft tissue mobilization around knee joint, strengthening exercise (Quad set, SLR, sidelying hip abduction, standing hamstring curls, sitting knee extension, step-up, wall slide to $45^{\circ}$ knee flexion). Manual therapy was executed five times a week for 2 weeks. Outcome measures included hip abductor strength by using Biodex system 4 pro, anterior to posterior balance, medial to lateral balance, total balance by using Biodex balance system SD. Results: After the completion of the manual therapy, hip abductor strength was showed statistically significant improvements in pelvic belt group (p<.05). Anterior to posterior balance, medial to lateral balance, total balance were showed statistically significant improvements in pelvic belt group and placebo group (p<.05). There was a statistically significant difference between the two groups in hip abductor strength and there was no statistically significant difference in balance. Conclusions: This results suggest that manual therapy using pelvic compression belt has could be used for selective muscle activation of the hip abductor muscle and has useful in hip abductor strength and balance ability in TKR patients.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.