• Title/Summary/Keyword: 수직형 풍력터빈

Search Result 12, Processing Time 0.021 seconds

Optimum Design of a Wind Power Tower to Augment Performance of Vertical Axis Wind Turbine (수직축 풍력터빈 성능향상을 위한 풍력타워 최적설계에 관한 연구)

  • Cho, Soo-Yong;Rim, Chae Hwan;Cho, Chong-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.3
    • /
    • pp.177-186
    • /
    • 2019
  • Wind power tower has been used to augment the performance of VAWT (Vertical Axis Wind Turbine). However, inappropriately designed wind power tower could reduce the performance of VAWT. Hence, an optimization study was conducted on a wind power tower. Six design variables were selected, such as the outer radius and the inner radius of the guide wall, the adoption of the splitter, the inner radius of the splitter, the number of the guide wall and the circumferential angle. For the objective function, the periodic averaged torque obtained at the VAWT was selected. In the optimization, Design of Experiment (DOE), Genetic Algorithm (GA), and Artificial Neural Network (ANN) have been applied in order to avoid a localized optimized result. The ANN has been continuously improved after finishing the optimization process at each generation. The performance of the VAWT was improved more than twice when it operated within the optimized wind power tower compared to that obtained at a standalone.

MPPT and yaw-axis control of parallel type wind turbine (병렬형 풍력 발전시스템의 MPPT 및 yaw축 제어)

  • IM, Jong-Wook;CHOY, Ick
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.250-251
    • /
    • 2010
  • 본 연구는 수평축(horizontal axis) 풍력 터빈에 의해서 수직축 발전기를 운전하는 구조 및 그 운전 방식에 관한 것으로서 바람에 의해 수평축 터빈 로터로 입력된 회전력을 기계적으로 두 개의 수직축 회전 성분으로 변환하여 이들로부터 전기 에너지를 얻어내고 필요에 따라 터빈 날개가 바람이 부는 방향을 향하도록 yaw-axis 제어를 하는 기술에 관한 것이다.

  • PDF

An Experimental Study for Efficient Design Parameters of a Wind Power Tower (풍력타워의 효율적인 설계변수에 대한 실험적 연구)

  • Cho, Soo-Yong;Choi, Sang-Kyu;Kim, Jin-Gyun;Cho, Chong-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.2
    • /
    • pp.114-123
    • /
    • 2018
  • Wind power tower (WPT) has been used to augment the performance of vertical axis wind turbine (VAWT). However, the performance of the WPT depends on several design parameters, such as inner and outer radius, or number of guide walls. Therefore, an experimental study was conducted to investigate efficient design parameters on the WPT. A wind tunnel was utilized and its test section dimension was 2m height and 2.2m width. One story model of the WPT was manufactured with seven guide walls and a VAWT was installed within the WPT. Three different sizes of guide walls were applied to test with various design parameters. The power coefficients were measured along the azimuthal direction in a state of equal inlet velocity in order to compare its performance relatively. The experimental results showed that the gap between the inner radius of the WPT and the rotating radius of the VAWT was a major parameter to improve the performance of VAWT within the WPT.

Numerical Investigation on the Flow Noise Characteristics of the Hybrid Vertical-axis Wind Turbine (복합형 수직축 풍력발전기의 유동소음특성에 관한 수치적 고찰)

  • Kim, Sanghyeon;Cheong, Cheolung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.351-357
    • /
    • 2014
  • In this paper, flow noise characteristics of the hybrid vertical-axis wind turbine is investigated. Hybrid vertical-axis wind turbines consisting of two types of vertical-axis wind turbines, Savonius and Darrieus, are devised to maximize merits of one turbine and thus minimize demerits of the other turbine. In order to predict flow noise radiating from hybrid vertical-axis wind turbines, hybrid computatioinal aero acoustic techniques are used. First, unsteady flow fields around the turbine are predicted using computational fluid dynamics method. Then, the flow noise radiations from the turbines are predicted by applying acoustic analogy to the predicted flow fields. Based on numerical results, noise characteristics of a hybrid vertical-axis wind turbine is investigated and is compared with those of Savonius and Darrieus wind turbines.

Aerodynamic method of H-Darrieus wind turbines (H-다리우스형 풍력터빈의 공력설계 방법의 구축)

  • Jeong, Suyun;Chang, Semyeong;Lee, Jangho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.179.2-179.2
    • /
    • 2010
  • In this study, we have constructed the method of design about H-Darrieus wind turbine, a kind of VAWT(vertical axis wind turbine). The NACA 0012 airfoil is chosen for the blade, and DMS(double multiple streamtube) theory is used for the analysis. The flow field is computed with numerical solution of rotating Navier-Stokes equations. From the result of experimental data of power coefficient curves, the validity of the present research is checked. Through the non-dimensional parameter analysis for the wind turbine design, we estimated the efficiency of wind turbine with the resultant Cp's, with which an efficient design of VAWT is achieved, and aerodynamic characteristics are presented systematically.

  • PDF

An Experimental Study on the Aerodynamic Performance of High-efficient, Small-scale, Vertical-axis Wind Turbine (고효율 소형 수직형 풍력터빈의 공력성능에 관한 실험적 연구)

  • Park, Jun-Yong;Lee, Myeong-Jae;Lee, Seung-Jin;Lee, Seung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.580-588
    • /
    • 2009
  • This paper summarizes the experimentally-measured performance of small-scale, vertical-axis wind turbine for the purpose of improving the aerodynamic efficiency and its controllability. The turbine is designed to have a Savonius-Type rotor with an inlet guide-vane and an side guide-vane so that it achieves a higher efficiency than any lift- or drag-based turbines. The main design factors for this high-efficient, vertical wind turbine are the number of blades (Z), and the aspect ratio of Height/Diameter (H/D) among many. The basic model has the diameter of 580mm, the height of 464mm, and the blade number of 10. The maximum power coefficient of 0.50 was experimentally measured for the above-mentioned specifications. The inlet-guide vane ensures the maximum efficiency when the angle of attack to the rotor blade lies between $15^{\circ}$ and $20^{\circ}$. This experimental results for the vertical-axis wind turbine can be applied to the preliminary design of turbine output curve based on the wind characteristics at the proposed site by controlling its aerodynamic performance given as a priori.

MPPT and Yawing Control of a New Horizontal-Axis Wind Turbine with Two Parallel-Connected Generators (수평 병렬형 풍력 발전기의 요각 및 MPPT 제어)

  • Lee, Kook-Sun;Choy, Ick;Cho, Whang;Back, Ju-Hoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.81-89
    • /
    • 2012
  • Commonly used horizontal-axis wind turbines (HAWT) have the following structure: two or three blades, a nacelle which contains power converting equipments, generators, and a tower which supports the nacelle. The generated power is transmitted from the nacelle to the ground. Due to this structure, the power transmission lines are twisted when the nacelle is yawing. Thus, slip ring or additional yaw control mechanism is required. We propose a new structure of HAWT which is free of this transmission line problem. Moreover, the size of inverter can be reduced since two generators are connected in parallel in our mechanism so that power is distributed. A controller for yawing is developed so that it works in harmony with the controller for power generation. A MPPT (Maximum Power Point tracking) algorithm is implemented for the proposed system and efficiency of the system is validated by simulation.

An Experimental Study for the Performance Analysis of a Vertical-type Wind Power Generation System with a Cross-flow Wind Turbine (횡류형 터빈을 적용한 수직축 풍력발전시스템의 성능평가를 위한 실험 연구)

  • Cho, Hyun-Sung;Chung, Kwang-Seop;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1272-1278
    • /
    • 2014
  • In this experimental study for the current growing offshore wind, a wind tunnel test was conducted to examine the performance of the vertical-type cross-flow wind turbine power generation system. Due to the limited size of the test section of the wind tunnel, the inlet guide vane of the original wind power generation was scaled down to about 1/5 and the turbine impeller diameter was also reduced to 1/2 of the prototype impeller. The number of the impeller blade is another important parameter to the output power of the wind power generation system and the number was varied 8 and 16. From the analysis of the experimental result, the output brake power of the model wind turbine was measured as 278watts with the 16-blade at 12 m/s of the rated wind speed and the rated brake power of the prototype wind turbine is calculated to 3.9kW at the rated operating condition.

Analysis of Unsteady Blade Forces in a Vertical-axis Small Wind Turbine (수직형 소형풍력터빈의 비정상 익력 평가)

  • LEE, SANG-MOON;KIM, CHUL-KYU;JEON, SEOK-YUN;ALI, SAJID;JANG, CHOON-MAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.2
    • /
    • pp.197-204
    • /
    • 2018
  • In the present study, unsteady flow analysis has been conducted to investigate the blade forces and wake flow around a hybrid street-lamp having a vertical-axis small wind turbine and a photovoltaic panel. Uniform velocities of 3, 5 and 7 m/s are applied as inlet boundary condition. Relatively large vortex shedding is formed at the wake region of the photovoltaic panel, which affects the increase of blade torque and wake flow downstream of the wind turbine. It is found that blade force has a good relation to the variation of the angle of attack with the rotation of turbine blades. Variations in the torque on the turbine blade over time create a cyclic fluctuation, which can be a source of turbine vibration and noise. Unsteady fluctuation of blade forces is also analyzed to understand the nature of the vibration of a small wind turbine over time. The detailed flow field inside the turbine blades is analyzed and discussed.

Study for Dynamic Stall Characteristics of Vertical Axis Wind Turbine Airfoil (수직형 풍력터빈 익형의 동특성 분석)

  • Kim, Cheol-Wan;Cho, Tae-Whan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.478-481
    • /
    • 2009
  • As a first step for aerodynamic analysis of vertical axis wind turbine, dynamic stall characteristics of airfoil was investigated. Dynamic stall of wind turbine airfoil is caused by severe variation of angle of attack and relative velocity of flow around airfoil. Angle of attack and relative velocity can be expressed with tip speed ratio. Variation of angle of attack is strongly dependent on the tip speed ratio. For tip speed ratio, 1.4 and free stream velocity, 15m/s, dynamic stall characteristics of wind turbine airfoil is compared with those of oscillating airfoil having same angle of attack variation.

  • PDF