• Title/Summary/Keyword: 수직온도분포

Search Result 147, Processing Time 0.028 seconds

A Study on Cooling Condition for Quality Improvement of Rotary Molding Machine (회전성형기의 품질 향상을 위한 냉각 조건에 관한 연구)

  • Kang, Jeong-Seok;Kim, In;Lee, Myungjae;Yoon, Jai-young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.367-371
    • /
    • 2019
  • The molding for hollow products used widely in industry is rotational molding by heating and cooling. Uniform cooling is required to improve the quality of the product, and rapid cooling is required to improve the productivity. In this paper, the cooling condition is largely classified into the case of no forced cooling by the fan and forced cooling by the fan. In addition, when forced cooling by the fan is not performed, the condition for stopping the molding machine horizontally and the condition for stopping the molding machine vertically were classified. To confirm the forced cooling by the fan, the conditions were set such that only the molding machine rotates while the fan is not running and the upper and lower fans operate when only the lower fan is operated. The surface temperature of the rotary molding machine was analyzed by the STAR-CCM+ program for the case of air-cooling. The temperature distribution of the rotary molding machine was analyzed for five conditions and the temperature distribution for cooling was compared under each condition. Among the five cases, Case 4 was lowest at approximately 35 ℃ after 900sec.

Analysis Models of Concrete Slabs-on-Grade Considering Horizontal Resistance at Slab Bottom and Behavior under Thermal Loads (슬래브 하부 수평저항을 고려한 지반위의 콘크리트 슬래브 해석 모델 및 온도하중에 의한 거동 분석)

  • Kim Seong-Min;An Zu-Og
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.271-282
    • /
    • 2006
  • The behavior of the concrete slabs on grade considering the horizontal resistance at the slab bottom, which exists due to the shear resistance of the foundation and the friction between the slab and the foundation, has been investigated when the slabs-on-grade are subjected to the thermal load. Analytical formulations have been developed to include the effect of the horizontal resistance at the slab bottom employing the thin plate on an elastic foundation that is widely used for the analysis of concrete slabs-on-grade and rigid pavement systems. Finite element formulations have then been developed using the plate bending elements and the flat shell elements. The solutions from the analytical and numerical models have been compared and showed very good agreement. The sensitivity of the horizontal resistance to the stresses of the concrete slab has been investigated with various values of the slab thickness, elastic modulus, and vortical stiffness of the foundation when subjected to the temperature gradient between the top and bottom of the slab and the uniform temperature drop throughout the slab depth. The analysis results show that the horizontal resistance at the plate bottom can significantly affect the stresses of the slab when the thermal loads are applied.

Numerical Analysis of Molten Carbonate Fuel Cell Stack Using Computational Fluid Dynamics (CFD를 이용한 용융탄산염 연료전지 스택의 수치모사)

  • Lee, Kab-Soo;Cho, Hyun-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.155-161
    • /
    • 2005
  • In this paper, commercial CFD program FLUENT v5.3 is used for simulation of MCFC stack. Besides using conservation equations included in FLUENT by default, mass change, mole fraction change and heat added or removed due to electrochemical reactions and water gas shift reaction are considered by adding several equations using user defined function. The stacks calculated are 6 and 25 kW class coflow stack which are composed of 20 and 40 unit cells respectively. Simulation results showed that pressure drop took place in the direction of gas flow, and the pressure drop of cathode side is more larger than that of anode side. And the velocity of cathode gas decreased along with the gas flow direction, but the velocity of anode gas increased because of the mass and volume changes by the chemical reactions in each electrodes. Simulated temperature profile of the stack tended to increase along with the gas flow direction and it showed similar results with the experimental data. Water gas shift reaction was endothermic at the gas inlet side but it was exothermic at the outlet side of electrode respectively. Therefore water gas shift reaction played a role in increasing temperature difference between inlet and outlet side of stack. This results suggests that the simulation of large scale commercial stacks need to consider water gas shift reaction.

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.

IGRINS로 관측 가능한 태양계 천체에 대한 사전 연구

  • Seo, Haeng-Ja;Kim, Sang-Jun;Sim, Chae-Gyeong;Son, Mi-Rim;Greathouse, Thomas K.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.154.2-154.2
    • /
    • 2011
  • 행성 및 타이탄과 같은 태양계 내의 면천체(extended source)를 관측하기 위해서는 공간분해능이 높은 대형망원경과 파장분해능이 높은 분광기가 필요하다. 특히 분광 관측 자료를 이용하면 행성 및 타이탄의 대기 구성 성분 및 그 성분비, 온도 분포, 구름과 연무 등의 수직 구조 등을 알 수 있다. 최근 연구에서는 구름, 연무, 비 등의 생성 과정에 불포화/초과포화 상태의 메탄, 에탄, 에틸렌 등이 관여하는 것이 새롭게 알려져 보다 활발한 후속 연구가 필요하다. 현재 개발 중인 IGRINS는 적외선 영역의 H band($1.49{\sim}1.8{\mu}m$)와 K band($1.96{\sim}2.46{\mu}m$)를 동시에 관측할 수 있고, McDonald 2.7m 망원경에 부착할 때 R~40,000의 높은 분해능을 가지는 장비로서 태양계 천체를 관측하는 데에 매우 적합하다. 따라서 향후 IGRINS가 본격적으로 가동될 때 얻을 수 있는 자료에 대한 사전 연구가 필요하며, 이는 대형 망원경 및 고분산 분광기를 이용한 관측, 자료 처리 및 분석 등의 경험에 기반을 두어 진행되어야 한다. 이에 NIFS/Gemini에 의해 관측된 타이탄 분광 자료와 TEXES/IRTF에 의해 획득된 목성극지방의 분광 자료를 분석하는 사전 연구를 진행하고 있다. 목성에 대해서는, 극지방에서 관측되는 hotspot, warm, normal 지역의 근적외선 영역 분광선 분석을 통해 기존에 결정되어 있지 않은 극지방 성층권의 고도에 따른 온도분포를 알아본다. 타이탄에 대해서는, 근적외선 영역의 메탄흡수밴드에서 관측된 주연증광(Limb brightening) 현상을 복사전달모델로 구현함으로써 어떤 기작이 이 현상에 가장 큰 영향을 미치는지에 대해 알아본다. 이런 태양계 천체 자료에 대한 연구는 향후 mission 및 rover 작업을 수행함에 있어 기본적인 정보로서 활용될 수 있다.

  • PDF

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.

A Development of Seepage Analysis Model for Unsaturated Soil during Rainfall (강우시 불포화지반의 침투해석모형 개발)

  • Lee, Jung-Sik;Han, Heui-Soo;Jang, Jin-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.796-800
    • /
    • 2009
  • 토목구조물 및 사면의 붕괴는 집중호우가 내리는 경우 많이 발생하고 있으며, 특히 사면에서는 붕괴까지의 변형이 급속히 진행되어 이를 사전에 예방하기는 매우 어려운 현실이다. 침투 및 배수과정에서의 사면 붕괴는 강우침투로 인한 지반의 물리적 특성변화가 직접적으로 사면의 안전계수 변화에 영향을 주는 것으로 판단되며, 이때 발생하는 물리적 특성변화로는 침투시 사면 내 지반의 단위 중량은 증가하여 전단응력의 증가 및 전단강도 감소현상이 발생하며, 이와 반대로 사면 내 배수로 인하여 전단응력의 감소 및 전단강도의 증가현상이 발생한다. 따라서 본 연구에서는 강우침투로 발생하는 지반의 포화도 변화를 지반 내 투수계수의 함수로 설명하여 강우로 인한 지반의 침투 및 배수과정을 규명하고자 한다. 일반적으로 지반 내 지하수의 침투과정은 라플라스 공식을 적용한다. 그러나 라플라스 공식은 정상 상태(Steady State)일 경우에만 사용할 수 있고, 강우 등으로 인한 지하수의 수두 변화가 발생한 비정상 상태(Unsteady State)의 경우에는 부적합하므로 사면과 옹벽 등의 토질구조물에서는 안전성 변화를 계산할 수 없다. 이를 위해 사면 내 지반의 침투 및 배수과정을 투수계수의 함수로 나타내어, 강우의 침투과정을 Fourier Series, 변수분리법 및 섭동함수를 사용하여 식으로 유도함으로서 강우에 의한 지반의 침투 및 배수과정에 따른 사면 내 지하수의 분포를 예측한다. 침투과정 해석을 위하여 지표에서 포화대까지의 깊이 10m의 모델사면 및 지표부터 포화대까지의 포화도는 직선으로 비례한다는 가정을 적용한다. 먼저 푸리에 급수를 이용, 시간에 따른 온도를 열전달에 관하여 편미분하여 발생하는 열확산계수를 투수계수로 변환함에 따라 지하수의 시간과 수직방향거리에 대한 지반의 포화도를 산정한다. 변수분리법은 산정된 포화도에 지반의 초기조건과 경계조건를 고려하기 위해 적용하며, 변수분리법에 의해 산정된 지하수 분포를 섭동함수법으로 과도 및 정상상태로 분류한다. 본 연구의 수행으로 인해 얻어진 결과를 요약하면 다음과 같다. 첫째, Fourier Series와 변수분리법, 섭동함수를 이용하여 강우에 의한 지반의 포화도 변화를 수식적으로 나타낼 수 있으며 둘째, 지반에서의 강우침투과정을 식으로 표현함으로서, 깊이별 시간에 따른 포화도의 영역이 상부로부터 하부로 전이되는 과정을 알 수 있다. 셋째, 푸리에 급수를 이용한 지반의 침투계산으로 강우로 인한 지반의 포화영역 및 불포화영역을 명확히 구분할 수 있으며, 각 깊이별 포화도를 계산하여 각 구간에서 불포화구간의 전단강도에 대한 보다 정확한 계산이 가능하리라 판단된다.

  • PDF

Occurrence of Diatom in the Late Quaternary Sediments of the Northeastern East Sea (Sea of Japan) and its Paleoceanographic Changes (동해 북동부해역 제 4기 후기 퇴적물의 규조 산출과 고해양학적 변화)

  • Shin, Y.N.;Ikehara, K.;Yoon, H.I.;Kim, Y.;Woo, K.S.;Khim, B.K.
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.305-319
    • /
    • 2000
  • A total of 50 diatom species and 1 subspecies belonging to 31 genera except Chaetoceros resting spores were identified in the 45 sediments subsampled from a gravity core GH98-1223 collected from the western Hokkaido Island located in the northeastern East Sea (Sea of Japan). The most dominant species is Thalassionema nitzschioides (Grunow) Hustedt, ranging 29 to 59% of the total assemblages, and most species including Denticulopsis seminae (Simonsen and Kanaya) Simonsen and Pseudoeunotia doliolus (Wallich) Grunow were less than 5% in average. Frequencies of cold-water species are generally higher than those of warm-water species and the vertical distribution of cold-water species was largely opposite to that of warm-water species in spite of ecological habitat difference. Frequency of cold-water species, D. seminae is reverse to that of P. doliolus, an indicator of the Tsushima Warm Current, which is consistent with diatom temperature value (T$_{d}$ value). The variation of T$_{d}$ values shows that the upper part of core with greater-than-average T$_{d}$ values represents postglacial warming trend. These T$_{d}$ values clearly demonstrate that the study area located in the northern part of the East Sea is gradually influenced by Tsushima Warm Current. In addition, the zig-zag variation in the lower part reflects the unstable seawater for diatom habitat. Chaetoceros resting spores indicating productivity and upwelling was 5.3 to 40%, with maximum peak at 80 cm. Chaetoceros resting spores/Chaetoceros vegetative cells, an indicator of relative amounts of biogenic material in the sediments was high at the upper 80 cm level, corresponding to the change of T$_{d}$ values. On the basis of diatom assemblages, the northeastern part of East Sea has experienced the effects of Tsushima Warm Current during the postglacial period of Holocene, which is similar to the modem climatic environment. However, the variation of P. doliolus reflects that the intensity of Tsushima Warm Current has been oscillated in the East Sea.

  • PDF

Characteristics of Meteorological Variables in the Leeward Side associated with the Downslope Windstorm over the Yeongdong Region (영동지역 지형성 강풍과 관련된 풍하측 기상요소의 특징)

  • Cho, Young-Jun;Kwon, Tae-Yong;Choi, Byoung-Cheol
    • Journal of the Korean earth science society
    • /
    • v.36 no.4
    • /
    • pp.315-329
    • /
    • 2015
  • We investigated the characteristics of meteorological conditions related to the strong downslope wind over the leeward side of the Taebaek Mountains during the period 2005~2010. The days showing the strong wind exceeding $14ms^{-1}$ in Gangwon province were selected as study cases. A total of 15 days of strong wind were observed at Sokcho, Gangneung, Donghae, and Taebaek located over the Yeongdong region. Seven cases related to tropical cyclone (3 cases) and heavy snowfall (2 cases) and heavy rainfall (2 cases) over the Yeongdong region were excluded. To investigate the characteristics of the remaining 8 cases, we used synoptic weather chart, Sokcho radiosonde, Gangneung wind profiler and numerical model. The cases showed no precipitation (or ${\leq}1mm\;day^{-1}$). From the surface and upper level weather chart, we found the pressure distribution of southern high and northern low pattern over the Korean peninsula and warm ridge over the Yeongdong region. Inversion layer (or stable layer) and warm ridge with strong wind were located in about 1~3 km (925~700 hPa) over mountains. The Regional Data Assimilation and Prediction System (RDAPS) indicated that warm core and temperature ridge with horizontal temperature gradient were $0.10{\sim}0.23^{\circ}C\;km^{-1}$ which were located on 850 hPa pressure level above mountaintop. These results were summarized as a forecasting guidance of downslope windstorm in the Yeongdong region.

The effect of Thermal Distribution on $LaSc_3(BO_3)_4$ Crystal Growth by Cz Method ($LaSc_3(BO_3)_4$ 단결정 성장조건)

  • 장영남;배인국
    • Korean Journal of Crystallography
    • /
    • v.9 no.1
    • /
    • pp.21-29
    • /
    • 1998
  • The rare-earth orthoborate family, RM3(BO3)4 is known to be the most promising material for the microlaser host. To grow LaSc3(BO3)4 single crystal, the phase relation of the system LaBO3-ScBO3 was investigated by DTA method. LaSc(BO3)4 was the unique intermediate compound in the binary system the peritectic reaction point of which was 1495 ±2℃. Owing to the peritectic behavior of the compound, the crystal growth of the rare-earth Sc-borate was carried out by pulling from the melt-soultion of La1+xSc3-x(BO3)4. The optimal conditions for the growth of LaSc3(BO3)4 were determined by traditional CZ method : pulling speed 0.7mm/hr, rotation speed 7-10 rpm under reduction condition. Pt and Ir crucibles could be used for about 8-10 times of growth. The effect of thermal configurations on the temperature distribution was investigated. A special two-coordinate manipulator was made for the precise movement of thermocouples from the melt to the top of the furnace for several thermal configurations. The radial gradient on the melt surface depends strongly on the construction of the afterheater. On the other hand, the axial gradient was mainly propotional to both the opening degree of baffle plate and the mutual positions of crucible and heater.

  • PDF