• Title/Summary/Keyword: 수직강성

Search Result 335, Processing Time 0.025 seconds

The Estimated Stiffness of Rubber Pads for Railway Bridges (철도교용 고무패드의 강성 추정기법)

  • Oh, Saeh Wan;Choi, Eun Soo;Jung, Hie Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.307-316
    • /
    • 2005
  • This study analyzed the characteristics of four kinds of bridge rubber pads and suggested a method of determining the stiffness and the damping ratio of the pads.The stiffness of rubber pads can be estimated by a direct static test and a dynamic test indirectly.This study used both methods to determine the pad's stiffness.The damping ratio of pads can be obtained using the dynamic test and the damping ratio of polyurethane rubber pads was estimated to aproximate that of natural and chloroprene rubber pads.The polyurethane rubber pads are harder than natural and chloroprene rubber pads and thus carry larger load bearing capacity.In addition, they showed higher stiffness with the same shape factor than the others and thus are more available for bridge bearings.Although natural and chloroprene rubber pads are elongated to large deformation in the horizontal direction due to vertical loads, polyurethane rubber pads almost do not generate horizontal deformation due to vertical loads regardless of the thickness and hardness of the pads.Therefore, they do not need reinforced plate to restrict horizontal deformation.

Static and Dynamic Behavior of Disk Bearings under Railway Vehicle Loading (철도차량하중에 의한 디스크받침의 정·동적 거동특성)

  • Oh, Saeh Wan;Choi, Eun Soo;Jung, Hie Young;Kim, Hak Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.469-480
    • /
    • 2006
  • The goal of this study is to ases the static and dynamic behavior of disk bearings under railway vehicle loadings. Several static tests were conducted in a laboratory t bearings, all having the same kind of polyurethane disk as used in the static tests, were installed under a full-sized railway bridge and tested with a running locomotive, the tests results, the static and dynamic stiffness of the disk bearings were estimated and compared. the deformation of the disk bearings under the bridge was measured at varying disk bearing was almost half of that under dynamic loading. In addition, the dynamic stiffness of the fixed disk bearing was 80% higher than that of an expansion disk bearing, since the PTFE in the expansion bearing is displaced. The deformation of the disk bearing did not vary significantly with changes in locomotive's speed. The results of this study can contribute to fast-tracking the formulation of a design technique for disk bearings for railway bridges.

The Experimental Study for Fiber Reinforced Bearing (섬유보강 탄성받침의 실험적 특성 해석)

  • 문병영;강경주;강범수;김계수;박진삼
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.415-422
    • /
    • 2001
  • In this paper, the experimental study was carried out in order to compare the mechanical characteristics of multi-layer elastomeric isolation hearings where the reinforceing elements steel plates case and fiber-reinforcement case. Fiber-reinforced isolater which has the same dimension as the steel reinforced isolator had shown better efficiency in effective damping than NRB. The compression test has shown the corresponding results with the theoretical vertical stiffness in the case of flexible reinforcement. The fiber-reinforced isolator will be significantly lighter and could lead to a much less labor intensive manufacturing process.

  • PDF

Seismic Response of Arch Structure according to the Aspect Ratio and Columns (아치구조물의 형상비와 하부구조에 따른 지진응답특성에 관한 연구)

  • Seok, Keun-Young;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.3
    • /
    • pp.71-78
    • /
    • 2012
  • The dynamic behavior of spatial structures is different depending on the aspect ration of arch structure, as the rise-span ratio or open-angle, and these spatial structures show differently the character of seismic response in accordance with stiffness and connection of the lower support structures that are directly influenced by earthquake. Therefore, in this paper, dynamic analysis is conducted for seismic response of single layer arch structures by the influence of column's stiffness and connection, to reflect the different vertical and horizontal vibration mode of single layer arch structures. The vertical response of single layer arch structures is more influence by lower columns and the influence of column's connection rotational stiffness is not large, except to the hinged connections.

An Experimental Study on Fiber Reinforced Elastomeric Bearing (섬유보강 면진베어링의 실험적 특성 해석)

  • 문병영;강경주;강범수;김계수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • In order to study the characteristics of fiber reinforced bearing, the steel plates of laminated rubber bearing were replaced with fibers which have same effects of steel plates. The comparison of vertical test and horizontal test of laminated rubber bearing and fiber reinforced bearing shows that the effective damping of fiber reinforced bearing is higher than laminated rubber bearing. This result implies the high energy dissipation ability of fiber reinforced bearing under earthquake excitation. These fiber reinforced bearing can be applied to the low-coast building.

Evaluation on the Condition of Track Substructure Using GPR/PBS/LEWD (GPR/PBS/LFWD를 이용한 궤도하부 상태평가)

  • Kim Dae-Sang;Hwang Seon-Keun;Shin Min-Ho;Park Tae-Soon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.163-170
    • /
    • 2005
  • Track substructure (ballast, subgrade) should have sufficient strength and uniform stiffness to fully support track superstructure (rail, fastener, sleeper). Vertical support stiffness of track is strongly influenced by the condition of ballast and subgrade layers. Therefore, the evaluation of the condition of track substructure is very important to evaluate the vertical support stiffness of track. This paper proposes the trackbed evaluation system, which is composed of Ground Penetrating Radar (GPR), Portable Ballast Sample. (PBS), and Light Falling Weight Deflectomete. (LFWD), to diagnose track substructure. The laboratory and field tests are performed to evaluate the applicability of the proposed trackbed evaluation system.

Development of Isolators (Laminated Rubber Bearing) for the Seismic Isolation of LNG Storage Tanks (LNG 저장 탱크의 지진방지를 위한 면진베어링(LRB)의 개발)

  • 유춘화;김두훈;이동근;김남식;정우정
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.116-121
    • /
    • 1994
  • 지금까지 대형 구조물에 널리 사용되고 있는 Base Isolator는 특히, 지진하중에 대하여 상부 구조물의 지반분리(base isolation)을 이용한 지진제어를 목적으로 하기 때문에 Seismic Isolator라 한다. 일반적으로 면진베어링에는 LRB(Laminated Rubber Bearing) 방식과 R-FBI(resilient-friction base isolator) 방식으로 크게 나눌 수 있다. LRB 방식은 가장 널리 사용되는 면진베어링으로써 방진고무를 주된 재료로 하고 수직강성을 보강하기 위하여 steel plate를 조합하여 제작하며, 초기강성 및 에너지 소산능력을 증가시키기 위하여 단면중앙에 납(lead plug)를 삽입하기도 한다. R-FBI 방식은 방진고무 적층판 내부에 미끄럼판을 가지고 있으므로 LRB 방식에 비하여 더 큰 수평변위를 발생시킬 수 있다. 이번에 설계 제작한 면진베어링은 LNG 저장탱크의 Seismic Isolation을 목적으로 적용대상의 사양에 맞추어 설계 제작하고 성능평가 시험을 수행하여 LNG 저장탱크, 원자로, 대형 건축물등 지진으로부터 보호되어야 하는 대형구조물의 방진재로 적용할 수 있는가를 평가하고자 한다. 본 논문에서는 제작된 면진베어링의 설계를 검증하고 방진고무(HDR)재료의 물리적 특성시험, 축소모델에 의한 정적, 동적시험을 통하여 시험방법을 소개하고 이러한 시험결과를 기초로 하여 면진베어리의 성능을 평가하였으며, 면진베어링의 온도변화, 외부 수직하중의 변화등에 따른 특성변화와 LNG 저장탱크와 면진베어링의 체결방법에 따른 시험으로 체결방법을 검증하였으며, 대상물의 사양에 적합한가를 고찰하였다.

  • PDF

Seismic Behavior of the Spacial Structure with Seismic Isolation (면진장치를 적용한 대공간구조물의 지진응답 분석)

  • Kim, Gee-Cheol;Ju, Dong-Hyem
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.49-57
    • /
    • 2008
  • The seismic isolation systems could be used to reduce the seismic response of a structure. The natural period of a structure with seismic isolation system got be long to avoid the prominent seismic period. The purpose of this study is to analyzed the seismic behavior of the truss arch that is supported to column with LRB. Truss arch structures subjected to horizontal seismic have large horizontal and vertical response unlike seismic behavior of normal rahmen structures. When seismic load is applied to the truss arch with isolation systems, the horizontal acceleration response of the truss arch is reduced and the vertical seismic response is remarkably reduced. Also, the seismic behaviors of the truss arch with strengthen column as like lattice column are very similar to that of the truss arch supported to directly foundation. The Seismic Isolation system can be applied to reduce efficiently the seismic response of the spacial structure with not strong column.

  • PDF

Base Isolator의 제작 및 특성실험

  • 김남식;유춘화;이동근
    • Computational Structural Engineering
    • /
    • v.5 no.4
    • /
    • pp.41-45
    • /
    • 1992
  • 본 실험에서는 가장 널리 쓰이는 base isolator의 한 종류로서 laminated rubber bearing을 제작하여 정적 및 동적 특성실험을 수행하였다. 앞에서 간략하게 언급한 실험결과에 대한 분석자료는 상부구조물과 기초와의 분리를 목적으로 본 실험에서 제작한 base isolator의 활용가능성을 검증하였다. 일반적으로 base isolator가 갖는 특성을 대부분 포함하고 있지만 본 실험결과에서 얻은 개선점은 i) 수직강성의 보강 ii) mounting plate와의 볼트연결부분 보완 iii) 최대전단변형을 증가시키기 위해 base isolator의 전체높이 조정 등으로 요약할 수 있다.

  • PDF