• Title/Summary/Keyword: 수증기 밀도

Search Result 27, Processing Time 0.023 seconds

Electrochemical Characteristics of Electrolyte Membrane for Hydrogen Production in High Temperature Electrolysis (고온 수증기 전해 수소제조를 위한 전해질 막의 전기화학적 특성 고찰)

  • Choi Ho-Sang;Son Hyo-Seok;Sim Kyu-Sung;Hwang Gab-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.349-354
    • /
    • 2005
  • YSZ (yttria-stabilized zirconia) determined with an electrolyte that analyzed thermal stability along sintering condition and an electric characteristic. As sintering temperature increases by SEM, grain grows and it showed that pore decreases relatively. and confirmed effect by grain size. It evaluated that particle internal resistance and electric performance by resistance in an electrolyte and electricity conductivity measurement through ac impedance measurement in temperature of $800\~1000^{\circ}C$ in 2-probe method In order to recognize an electric characteristic. In dry process and wet process, density was each 6.13, 6.25 $g/cm^3$ and the relative density was each 98, 99$\%$ when sintering condition is $1400^{\circ}C$.

Preparation of Nano Size Cerium Oxide from Cerium Carbonate (탄산(炭酸)세륨으로부터 나노크기 산화(酸化)세륨 제조연구(製造硏究))

  • Kim, Sung-Don;Kim, Chul-Joo;Yoon, Ho-Sung
    • Resources Recycling
    • /
    • v.18 no.6
    • /
    • pp.24-29
    • /
    • 2009
  • Since cerium carbonate becomes porous cerium oxide by releasing carbon dioxide and vapour steam during calcination of cerium carbonate, nano size cerium oxide can be obtained by milling calcined cerium carbonate. Therefore cerium carbonate [$Ce_2(CO_3)3{\cdot}XH_2O$] is used generally for the preparation of nano size cerium oxide. In order to obtain nano size cerium oxide from cerium carbonate prepared by reactive crystallization of cerium chloride solution and ammonium bicarnonate solution, the effects of experimental variables in the milling and calcination of cerium carbonate, such as calcination temperature, milling time, rpm of planetary mill, amount of dispersant and ball size for milling on the size of cerium oxide was investigated in this study. Cerium oxide prepared with the conditions of calcination temperature of $700^{\circ}C$, milling time of 5 hour was 160nm mean particle size.

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.

On Securing Continuity of Long-Term Observational Eddy Flux Data: Field Intercomparison between Open- and Enclosed-Path Gas Analyzers (장기 관측 에디 플럭스 자료의 연속성 확보에 대하여: 개회로 및 봉폐회로 기체분석기의 야외 상호 비교)

  • Kang, Minseok;Kim, Joon;Yang, Hyunyoung;Lim, Jong-Hwan;Chun, Jung-Hwa;Moon, Minkyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.3
    • /
    • pp.135-145
    • /
    • 2019
  • Analysis of a long cycle or a trend of time series data based on a long-term observation would require comparability between data observed in the past and the present. In the present study, we proposed an approach to ensure the compatibility among the instruments used for the long-term observation, which would allow to secure continuity of the data. An open-path gas analyzer (Model LI-7500, LI-COR, Inc., USA) has been used for eddy covariance flux measurement in the Gwangneung deciduous forest for more than 10 years. The open-path gas analyzer was replaced by an enclosed-path gas analyzer (Model EC155, Campbell Scientific, Inc., USA) in July 2015. Before completely replacing the gas analyzer, the carbon dioxide ($CO_2$) and latent heat fluxes were collected using both gas analyzers simultaneously during a five-month period from August to December in 2015. It was found that the $CO_2$ fluxes were not significantly different between the gas analyzers under the condition that the daily mean temperature was higher than $0^{\circ}C$. However, the $CO_2$ flux measured by the open-path gas analyzer was negatively biased (from positive sign, i.e., carbon source, to 0 or negative sign, i.e., carbon neutral or sink) due to the instrument surface heating under the condition that the daily mean temperature was lower than $0^{\circ}C$. Despite applying the frequency response correction associated with tube attenuation of water vapor, the latent heat flux measured by the enclosed-path gas analyzer was on average 9% smaller than that measured by the open-path gas analyzer, which resulted in >20% difference of the sums over the study period. These results indicated that application of the additional air density correction would be needed due to the instrument heat and analysis of the long-term observational flux data would be facilitated by understanding the underestimation tendency of latent heat flux measurements by an enclosed-path gas analyzer.

Development of Internal Reforming Catalysts and Catalysts Forming Method using Homogeneous Precipitation (균일용액침전법을 이용한 내부개질촉매의 개발과 성형방법에 대한 연구)

  • Jung, Youshick;Rhee, Youngwoo;Koo, Keeyoung;Jung, Unho;Youn, Wanglai;seo, Yongseog
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.223.2-223.2
    • /
    • 2010
  • 용융탄산염 연료전지(MCFC)는 $650^{\circ}C$에서 작동하는 고온형 연료전지 시스템이다. 이 시스템은 천연가스 등을 개질하여 생산된 수소를 바로 전기로 생산할 수 있는 시스템으로 열효율이 높으며, 현재 대체 발전시스템으로 각광을 받고 있다. MCFC는 개질방식에 따라 내부개질 방식과 외부개질 방식이 있다. 내부개질 방식은 수소를 생산하는 개질기가 스택내부에 장착된 형식으로 천연가스를 스택내부에서 개질하여 바로 전기를 생산하는 방식이다. 이 내부개질반응에 사용되는 촉매로는 알루미나에 담지된 니켈(Ni) 계열촉매이 주로 쓰이고 있다. 또한 내부개질촉매의 형태는 작은 원주형의 촉매형태로 성형되어 사용된다. 이 성형된 촉매의 크기가 바로 내부개질 스택의 크기를 결정하는 중요한 요소이다. 그래서 촉매의 크기는 되도록이면 작게 성형하는 것이 중요하다. 그러나 촉매의 크기가 너무 작으면 촉매를 성형하는데 큰 어려움이 생기게 된다. 본 연구에서는 니켈 촉매를 공침법이 아닌 균일용액침전법을 이용하여 제조하였으며, 이 촉매를 이용하여 지름이 약 2 mm 이하로 촉매를 압출성형하는 방법을 연구하였다. 먼저 요소(urea)를 이용한 균일용액침전법으로 촉매를 제조하였다. 최적의 촉매 합성조건을 살펴보기 위해서, 반응 온도를 80, 85, 90, 95, $100^{\circ}C$로 변화 시키면서 제조된 촉매의 특성을 살펴보았다. 그리고 촉매의 적절한 니켈 양을 알아보기 위해서 니켈의 양을 30, 40, 50, 60, 70 wt%로 변화 시켰으며, 조촉매로 사용되는 MgO 양을 5, 10, 15, 20 wt%로 변화 시켜서 제조된 촉매의 특성을 살펴보았다. 물성을 비교하기 위해서, X-선 회절분석(XRD) 및 TPR, 물리화학흡착을 하였다. 그 결과 침전반응온도가 $80^{\circ}C$에서 촉매가 가장 좋은 물성을 보였으며, 우수한 개질성능을 보였다. 그리고 촉매 활성물질인 니켈의 함량은 50 wt% 정도가 가장 적절한 함량이었으며, MgO의 함량이 15 wt%일 때 가장 우수한 물성과 개질 성능을 보여주었다. 이 촉매들은 공침법으로 제조된 상용촉매와 비교하였을 때, 보다 우수한 물성과 개질성능 보였다. 그래서 이 촉매를 균일침전법을 이용하여 대량으로 제조한 다음 압출성형 방법을 이용하여 촉매를 원주형으로 제조하였다. 먼저 제조된 촉매는 별도의 분쇄작업(볼밀 혹은 제트밀)을 거치지 않아도 입자사이즈가 약 $4{\mu}m$ 수준이 나오도록 촉매 제조조건을 조절 하였다. 그리고 소량의 Methyl cellulose(MC) 바이더와 물만 사용하여 촉매를 혼합한 다음 스크류 압출기를 이용하여 촉매를 성형하였다. 이 촉매는 지름이 약 2 mm 이하로 제조할 수 있었으며, 기계적 강도는 타정기로 성형한 상용촉매보다 우수하였다. 그리고 촉매 성능 또한 상용촉매와 비교하였을 때, 우수한 성능 보였다. MCFC용 내부개질 촉매로 균일용액침전법을 사용한 촉매가 적합하다고 판단되며, 압출성형에도 적합하다고 판단되었다.

  • PDF

Experimental Study of Performance of PEMFC Operated in Dead-End Mode (수소극 Dead-End 모드 고분자 전해질 연료전지의 실험적 연구)

  • Ji, Sang-Hoon;Hwang, Yong-Sheen;Choi, Jong-Won;Lee, Dae-Young;Park, Joon-Ho;Jang, Jae-Hyuk;Kim, Min-Soo;Cha, Suk-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.643-648
    • /
    • 2010
  • Portable fuel cells are commonly operated in the dead-end mode because of such as high fuel utilization. However, the performance of such systems deteriorates continuously with an increase in the amount of by-products such as water vapor and nitrogen. In this study, to verify the effect of water vapor on Proton Exchange Membrane Fuel Cells (PEMFCs), constant-load experiments were carried out for a current density of 600 mA/cm2 and a voltage of 0.4 V, respectively. The performance of the cell was more stable under constant voltage conditions than under constant current density conditions. Condensed water accumulated in the anode channel near the cell outlet. The experimental results show how the relative humidity (RH = 0.15, 0.4 and 0.75) of air at the cathode side affect the performance of PEMFCs with dead-end anode. At RH values higher than 0.15, the mean power density increased by up to 51% and the mean purge duration decreased by up to 25% compared to the corresponding initial values.

Variation of Water Content and Thermal Behavior of Talc Upon Grinding: Effect of Repeated Slip on Fault Weakening (활석 분쇄에 따른 함수율 및 열적거동 변화: 단층의 반복되는 미끌림이 단층 약화에 미치는 영향)

  • Kim, Min Sik;Kim, Jin Woo;Kang, Chang Du;So, Byung Dal;Kim, Hyun Na
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.201-211
    • /
    • 2019
  • The particle size and crystallinity of fault gouge generally decreases with slip. Phyllosilicates including talc are known to be present in fault gouge and play an important role in fault weakening. In particular, the coefficient of friction varies depending on the presence of a water molecule on the surface of mineral. The purpose of this study is to investigate the effect of talc on fault weakening by changing the water content and dehydration behavior of talc before and after grinding, which systematically varied particle size and crystallinity using high energy ball mill. Infrared spectroscopy and thermal analysis show that the as-received talc is hydrophobic before grinding and the water molecule is rarely present. After grinding up to 720 minutes, the particle size decreased to around 100 ~300 nm, and in talc, where amorphization proceeded, the water content increased by about 8 wt.% and water molecule would be attached on the surface of talc. As a result, the amount of vaporized water by heating increased after grinding. The dihydroxylation temperature also decreased by ${\sim}750^{\circ}C$ after 720 minutes of grinding at ${\sim}950^{\circ}C$ before grinding due to the decrease of particle size and crystallinity. These results indicate that the hydrophobicity of talc is changed to hydrophilic by grinding, and water molecules attached on the surface, which is thought to lower the coefficient of friction of phyllosilicates. The repeated slip throughout the seismic cycle would consistently lower the coefficient of friction of talc present in fault gouge, which could provide the clue to the weakening of matured fault.