• Title/Summary/Keyword: 수소 누출

Search Result 121, Processing Time 0.026 seconds

Detection of fluorescence from soils contaminated with monoaromatic hydrocarbons (유류 오염 토양에서의 단일방향족 탄화수소 농도 측정을 위한 자외선 형광 분석에 관한 연구)

  • 김우진;박재우;이주인
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.35-44
    • /
    • 2002
  • In order to determine the contamination of the aromatic hydrocarbons in soil, a fiber-optic sensing technique with fluorescence detector has been proposed. Previous researches have shown that the optimal condition for detecting benzene, toluene, ethylbenzene, xylene (BTEX) was 260 nm /290 nm (excitation/emission wavelength). However, broader fluorescence spectra of BTEX-polluted soil sample ranging from 300 nm to 600 nm were observed. Additionally, the intensity of fluorescence increased with increasing BTEX concentration, which was conspicuous in the fine-particle soil, The overall results indicated that the suggested technique could be useful for in-situ monitoring system for subsurface oil-storage tank.

Self Ignition Phenomena of High Pressure Hydrogen Released into Tube with Diaphragm Rupture Conditions (튜브 내 누출되는 고압수소의 격막파열조건에 따른 자발점화 현상)

  • Lim, Han Seuk;Lee, Sang Yoon;Lee, Hyoung Jin;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.215-218
    • /
    • 2014
  • High combustion efficiency of hydrogen could make it an ideal source of green energy in the future. At this time, high pressure vessel is the most reasonable method of storing hydrogen. However, such a high pressurized vessel could pose a critical threat if ruptured. For this reason, it is important to understand the mechanism of hydrogen's self-ignition when a high-pressure hydrogen released into air. This paper presents several visualization images as experimental results using high-speed camera. From the visualization images, the ignition is initiated near rupture disk immediately after failure of disk. And the initial ignition and flame is stronger as a rupture pressure increases. However, this ignition region do not affect the general self-ignition mechanism when a high-pressure hydrogen is released into air through tue after failure of disk.

  • PDF

Spontaneous Ignition of High Pressure Hydrogen Gas released into Tube due to the Burst Pressure Variation (파열 압력에 따른 튜브 내 고압 수소 누출에 의한 자발점화 현상)

  • Lee, Hyoung Jin;Kim, Sung Don;Kim, Sei Hwan;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.93-96
    • /
    • 2012
  • The spontaneous ignition mechanism of high pressure hydrogen gas released into tube is well-deduced from previous studies. However, those results have a limit because the studies have been conducted at low burst pressure of about 10 MPa. In this study, the process or ignition feature are investigated with higher burst pressure of up to 30 MPa through numerical analysis. The results show that the trend of ignition became to be different with a burst pressure. While two reaction regions is important to initiate the ignition when burst pressure is about 10 MPa, the reaction of the core region does not play a role in ignition inside the tube when a burst pressure is above 20 MPa.

  • PDF

Effects of a wall on the self-ignition of sudden release of high-pressure hydrogen through a tube (벽면에 의한 고압 수소 누출에 따른 자발화 현상 특성 변화)

  • Kim, Seihwan;Park, Ji Hyun;Lee, SeungBok;Lee, Hyung Jin;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.245-246
    • /
    • 2012
  • The possibility that self-ignition can be generated near an obstacle is high in practical applications such as a hydrogen car. In this paper, experimental investigations were suggested to understand the effects of a wall on self-ignition phenomena through high-speed images. The results showed that the existence of a wall could not change the ignition phenomena itself irrespective of wall height and burst pressure. However, when a strong flame was induced in the tube, a wall could promote the flame stabilization.

  • PDF

Self-ignition of high-pressure hydrogen gas released into tube (튜브내 고압수소가스 누출에 따른 자발점화 현상 유동가시화 연구)

  • Kim, Yeong Ryeon;Lee, Hyoung Jin;Kim, Sei Hwan;Jeung, In Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.247-248
    • /
    • 2012
  • Unidentified self-ignitions were reported when the high-pressure hydrogen gas suddenly leaked out. This paper presents a flow visualization study to investigate the self-ignition mechanism in a test tube how the ignition process is initiated and the flame propagates with measurement of a number of pressure and light sensors installed in the tube supported the analysis of the self-ignition. The test result showed the location of the self-ignition taken place and critical static pressure at the boundary layer for self-ignition.

  • PDF

Operation Characteristics of the kW-class PEMFC Stack (kW급 고분자전해질 연료전지 스택의 운전 특성)

  • 최형준;안상렬;조성아;하홍용;오인환;홍성안;임태원
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.239-244
    • /
    • 1999
  • 고분자전해질 연료전지는 다른 형태의 연료전지에 비하여 전류밀도가 크고 구조가 간단하며 전해질의 누출이나 손실의 염려가 없어 수송용 무공해 차량의 동력원으로서 아주 적합한 시스템이다. 또한 빠른 시동과 응답특성, 우수한 내구성을 가지고 있고 연료로 수소 이외에도 메탄올이나 천연가스를 개질하여 사용할 수 있다는 장점이 있다 [1, 2]. 고분자전해질 연료전지는 원래 우주선, 군사용 등 특수 목적으로 사용되던 것이 1980년대 말에 이르러 도심지 대기오염을 저감시키기 위한 전기 자동차의 동력원 및 이동용 전원으로 사용될 것이 기대됨에 따라 전세계적으로 다시 연구 개발의 활기를 찾게 되었다.(중략)

  • PDF

A Study on Quantitative Risk Analysis & Model Application for Hydrogen Filling Center (수소충전시설에 대한 정량적 위험성 평가 및 모델적용에 관한 연구)

  • Shin, Jung-Soo;Byun, Hun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.87-101
    • /
    • 2012
  • In gas industries, the potential risks of serious accidents have been increased due to high technology application and process complexities. Especially, in case of gas-related accidents, the extent of demage is out of control since gas plants handle and produce combustible, flammable, explosive and toxic materials in large amounts. The characteristics of this kind of disaster is that accident frequency is low, while the impact of damage is high, extending to the neighboring residents, environment and related industries as well as employees involved. The hydrogen gases treated important things and it used the basic material of chemical plants and industries. Since 2000, this gas stood in the spotlight the substitution energy for reduction of the global warming in particular however it need to compress high pressure(more than 150 bar.g) and store by using the special cylinders due to their low molecular weight. And this gas led to many times the fire and explosion due to leak of it. To reduce these kinds of risks and accidents, it is necessary to improve the new safety management system through a risk management after technically evaluating potential hazards in this process. This study is to carry out the quantitative risk assesment for hydrogen filling plant which are very dangerous(fire and explosive) and using a basic materials of general industries. As a results of this risk assessment, identified the elements important for safety(EIS) and suggested the practical management tools and verified the reliability of this risk assessment model through case study of accident.

Analysis on the contamination and source of VOCs in groundwaters of Gwangju area (광주광역시의 지하수 중 휘발성유기화합물(VOCs)의 오염과 오염원 분석)

  • Yun, Uk;Cho, Byong-Wook;Eum, Chul-Hun;Sung, Ik-Hwan
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.389-404
    • /
    • 2003
  • VOCs were detected in the 21 groundwaters out of 37 groundwaters sampled from around the Hanam Industrial Complex and the Gwangju stream. Ten components of chlorinated aliphatic hydrocarbons of VOCs were detected in the 18 groundwater samples. Among them, total trihalomethanes (TTHM) concentration is in the range of $0.1~36.2{\;}\mu\textrm{g}/L$, CECs concentration is $2.3~190{\;}\mu\textrm{g}/L$, and chlorinated solvents concentration containing PCE, TCE, etc. is $0.1~124.2{\;}\mu\textrm{g}/L$ respectively. Ten components of the aromatic hydrocarbons of VOCs were detected in the 5 groundwater samples, but their concentration are less than $1{\;}\mu\textrm{g}/L$. Detection frequency and concentration of the chlorinated aliphatic hydrocarbons components from the groundwaters in the Hanam Industrial Complex are higher than those of nearby downtown Gwangju stream. VOCs components except for TCE are lower than the MCL of USGS drinking water standard. TCE concentration of the 2 groundwater samples is over MCL, whose concentrations are 5 and 25 times higher than MCL, respectively. TCE is detected from the H8 and H10 groundwater samples and CFCs is detected H8 and H11 groundwater samples in the Hanam Industrial Complex. TTHM in study area is estimated from leakage of the main waters or sewage waters. Because most of the studied groundwater is under an aerobic condition, aromatic hydrocarbons are well degraded. But chlorinated aliphatic hydrocarbons are degraded very slowly.

Cytogenetic and Medical Examination Report of Accidental Exposure of Nuclear Power Plant Worker using Multiple Assays (원자력 발전소 피폭자 건강영향평가 사례보고)

  • Lee, Jung-Eun;Yang, Kwang-Hee;Jang, Yun-Kun;Jeong, Mee-Seon;Kim, Chong-Soon;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.111-115
    • /
    • 2007
  • A deuterium oxide leakage accident occurred on October 4, 1999, at nuclear power plant in Korea. The concentration of tritium in air increased and 22 workers were exposed by tritium at that time. It is well known that tritium causes internal exposure. Therefore, we examined complete blood cell count, physical and biological dosimetry fur 13 workers among whole 22 workers to check the health effect and to evaluate the dose estimation of tritium exposure. The leukocyte count test, one of general blood test, was normal. The estimated doses were 0 - 4.44 mSv by physical dosimetry and 0-37 mGy by biological dosimetry. This dose does not exceed radiation dose limit, and the clinical symptoms of the exposed workers were not shown. The consistency between clinical sign and estimated dose means that physical and biological dosimetry were very useful especially in accident evaluation.

Estimation of the Concentration of HF in the Atmosphere Using Plant Leaves Exposed to HF in the Site of the HF Spill (불산 누출 사고 시 불산에 노출된 식물잎을 이용한 대기 중 불화수소 농도 추정)

  • Yim, Bongbeen;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.248-255
    • /
    • 2016
  • The leaves of three plant species, such as soybean, raspberry, and kudzu, exposed to hydrogen fluoride was collected in an area surrounding an emission source where the release accident occurred. The ultrasonic-assisted extraction and analysis of fluoride by ion chromatography was carried out. The mean concentration of fluoride in the leaves of three plant species exposed to hydrogen fluoride was $5,409{\pm}1,198mg\;F/kg\;dry\;wt$ and $788{\pm}339mg\;F/kg\;dry\;wt$, respectively. The mean fluoride concentration in ambient air were estimated to be $2.36{\pm}0.65mg/m^3$ ($2.89{\pm}0.79ppm$) and $0.35{\pm}0.15mg/m^3$ ($0.43{\pm}0.19ppm$) in exposed and unexposed sites, respectively. It seems likely that the passive monitoring using plant leaves could identify with respect to plant risk by fluoride in atmosphere.