• 제목/요약/키워드: 수면 다원 검사

Search Result 172, Processing Time 0.034 seconds

Case of a 19-Year-Old Male with Nocturnal Groaning (Catathrenia) (야간 신음소리를 주소로 내원한 19세 남자 환자 1례)

  • Kang, Hyun Tag;Lee, Yun Ji;Kim, Hyo Jun;Choi, Ji Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.25 no.2
    • /
    • pp.92-95
    • /
    • 2018
  • Catathrenia is a rare sleep disease characterized by monotonous groaning sounds that appear to be related with prolonged expiration, commonly experienced during rapid eye movement (REM) sleep. Catathrenia is also known as nocturnal groaning or sleep-related groaning and is currently categorized as a sleep-related breathing disorder. We present a rare case of a 19-year-old male with nocturnal groaning during non-REM sleep. We suggest that if catathrenia is suspected, polysomnography should be utilized to differentiate it from various sleep disorders such as snoring, central sleep apnea, sleep talking, parasomnia, and sleep-related movement disorders.

Detrended Fluctuation Analysis of Sleep Electroencephalogram between Obstructive Sleep Apnea Syndrome and Normal Children (소아기 수면무호흡증 환자와 정상 대조군 수면 뇌파의 탈경향변동분석)

  • Kim, Eui-Joong;Ahn, Young-Min;Shin, Hong-Beom;Kim, Jong-Won
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.1
    • /
    • pp.41-49
    • /
    • 2010
  • Unlike the case of adult obstructive sleep apnea syndrome (OSAS), there was no consistent finding on the changes of sleep architecture in childhood OSAS. Further understanding of the sleep electroencephalogram (EEG) should be needed. Non-linear analysis of EEG is particularly useful in giving us a new perspective and in understanding the brain system. The objective of the current study is to compare the sleep architecture and the scaling exponent (${\alpha}$) from detrended fluctuation analysis (DFA) on sleep EEG between OSAS and normal children. Fifteen normal children (8 boys/7 girls, 6.0${\pm}4.3$2.2 years old) and twelve OSAS children (10 boys/2 girls, 6.4${\pm}4.3$3.4 years old) were studied with polysomnography (PSG). Sleep-related variables and OSAS severity indices were obtained. Scaling exponent of DFA were calculated from the EEG channels (C3/A2, C4/A1, O1/A2, and O2/A1), and compared between normal and OSAS children. No difference in sleep architecture was found between OSAS and normal controls except stage 1 sleep (%) and REM sleep latency (min). Stage 1 sleep (%) was significantly higher and REM latency was longer in OSAS group (9.3${\pm}4.3$4.3%, 181.5${\pm}4.3$59.9 min) than in controls (5.6${\pm}4.3$2.8%, 133.5${\pm}4.3$42.0 min). Scaling exponent (${\alpha}$) showed that sleep EEG of OSAS children also followed the 'longrange temporal correlation' characteristics. Value of ${\alpha}$ increased as sleep stages increased from stage 1 to stage 4. Value of ${\alpha}$ from C3/A2, C4/A1, O1/A2, O2/A1 were significantly lower in OSAS than in control (1.36${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.04 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.05, and 1.36${\pm}4.3$0.07 vs. 1.41${\pm}4.3$0.05, p<0.05). Higher stage 1 sleep (%) in OSAS children was consistent finding with OSAS adults. Lower $'{\alpha}'$ in OSAS children suggests decrease of self-organized criticality or the decreased piling-up energy of brain system during sleep in OSAS children.

  • PDF

An embedded system for sleep-aid to reduce snoring (코골이 경감을 위한 임베디드 시스템 개발)

  • Park, Jin-Ho;Kim, Min-Ho;Kim, Sook-Hui;Jung, Yun-Sung;Moon, Ji-Hye;Ahn, Chang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1996_1997
    • /
    • 2009
  • 본 논문에서는 일반적으로 뇌파, 안전도, 근전도, 심전도, 동맥혈, 산소포화도, 복부와 흉부의 호흡운동, 호흡기류, 코골이, 몸의 자세 등을 이용하여 측정 하는 수면 다원검사를 근간으로 하여 보다 간편하게 수면상태를 측정하고 피드백할 수 있는 시스템을 개발하여 제시한다. 이 코골이 경감을 위한 임베디드 시스템을 통해 코골이로 인해 어려움을 겪는 사용자가 숙면을 취하고, 자신의 상태를 쉽게 모니터링 할 수 있을 것으로 기대된다.

  • PDF

Relatively Decreased Level of Subjective Daytime Sleepiness and Its Associated Factors in Patients with Primary Insomnia (일차성 불면증 환자에서의 주간 졸림증과 연관된 수면변인에 대한 연구)

  • Lee, Yu-Jin;Lee, Jin-Sung;Sohn, Chang-Ho;Lee, Eun-Hye;Moon, Pil-Sung;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.2
    • /
    • pp.117-121
    • /
    • 2005
  • Objectives: The purpose of this study was to assess the difference of subjective daytime sleepiness level between primary insomnia patients and healthy control subjects. We also investigated the relationship between subjective daytime sleepiness level and variables of nocturnal polysomnograghic sleep architecture of insomnia patients. Method: Total subjects were 87 patients with primary insomnia diagnosed with polysomnography and 88 normal controls. The daytime sleepiness level in each group was measured by Korean version of Epworth Sleepiness Scale (ESS). The correlations of ESS score and nocturnal polysomnographic variables were calculated in the patient group. Results: Patients with insomnia had the lower ESS scores than the control group. In patients group, the ESS score showed significant negative correlations with total sleep time, sleep efficiency%, and stage 2 sleep time%. The ESS score also showed significant positive correlations with number of awakenings, number of awakenings more than 2 minutes, and wake after sleep onset time. Conclusions: Insomnia patients showed lower level of subjective daytime sleepiness that may indicate their higher alertness comparing to control subjects. Daytime sleepiness of patients with insomnia was associated with polysomnographic variables including total sleep time, sleep efficiency%, stage 2 sleep time% and disrupted continuity of nocturnal sleep.

  • PDF

The Relationship of the Severity of Sleep Apnea Syndrome to the Resting Energy Expenditure and Leptin (수면무호흡증의 중증도와 안정시 에너지 대사 및 혈중 Leptin과의 관계)

  • Lee, Kwan-Ho;Shin, Kyeong-Cheol;Ahn, Jae-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.836-845
    • /
    • 1999
  • Background : Obesity is present in the majority of adult patients with obstructive sleep apnea(OSA) and is considered to be a major risk factor for its development. A reduction in body weight has been associated with substantial improvement in the severity of apnea. However, a variety of treatment strategies for obesity have yielded limited sucess. This study was done to determine resting energy expenditure(REE) in patients with obstructive sleep apnea and the correlation between the severity of sleep apnea and REE, and to investigate whether leptin influences REE and correlated with the severity of sleep apnea in 39 patients with OSA and 45 controls matched for obesity. Method : Overnight polysomnography was performed on all subjects using standard techniques. Measurements of REE were made using a Sensormedic Vmax 229 and a canopy system. Serum leptin concentration was measured by human leptin RIA kit of LINCO Research INC. Results : REE was greater in patients with OSA compared with controls, but there was no difference between the two groups on REE%. And also there was no significant correlation between anthropometric data, polysomnographic data and REE%. Serum leptin was linearly related to body mass index(BMI), apnea index, apnea hypopnea index and lowest arterial oxygen saturation($SaO_2$) but not related to REE%. Conclusion : This study suggests the followings. Firstly patients patients with sleep apnea have a pattern of obesity characterized by energy homeostasis at an elevated body weight set-point. In order to achieve a lower body weight in these patients, it may be necessary to increase energy expenditure by increasing physical activity. Secondly leptin level was not correlated with REE, suggesting that leptin may predominantly regulate body fat by altering eating behavior rather than calorigenesis. Lastly leptin level was significantly correlated with the severity of sleep apnea. These elevated level of leptin in patients of sleep apnea may be related to the obesity, however it needs further studies to determine the relationship between the severity of sleep apnea and serum leptin.

  • PDF

The Effect of Mandibular Protrusion on Dynamic Changes in Oropharyngeal Caliber (하악의 전방이동이 구인두 내경의 동적 변화에 미치는 영향)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.3
    • /
    • pp.193-202
    • /
    • 2010
  • The purpose of this study was to determine the sites of narrowing/obstruction and to measure the regional severity of narrowing through the evaluation of dynamic changes in upper-airway of healthy subjects. The selected 9 subjects were proved not to have any sleep-related disorder such as snoring or obstructive sleep apnea through clinical examination, radiological examination, sleep study with a portable recording system. Afterward, the Electron Beam Tomography was performed during the waking and sleeping state of subjects, with their mandible in resting and protruded position. Intravenous injection of Dormicum$^{(R)}$ was used for the induction of sleep. The maximum and minimum cross-sectional areas at each airway level during tidal ventilation were measured and the Collapsibility Index for each level of cross-section was also computed. In a comparison with results under variable conditions, the result was showed that the significant difference between each airway level divided with upper, middle, lower region of upper airway is not observed in the average minimum cross-sectional areas and Collapsibility Index. The significant difference only between in wake and sleep state was observed in the average minimum cross-sectional area at the lower region. Also, in wake state, the significant difference between resting and protrusive position of mandible for the average minimum was also observed in cross-sectional area at middle region. In sleep state, no significant difference between resting and protrusive position of mandible was observed in cross-sectional area and the Collapsibility Index.

Decreased Attention in Narcolepsy Patients is not Related with Excessive Daytime Sleepiness (기면병 환자의 주의집중 저하와 주간졸음증 간의 상관관계 부재)

  • Kim, Seog-Ju;Lyoo, In-Kyoon;Lee, Yu-Jin;Lee, Ju-Young;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.2
    • /
    • pp.122-132
    • /
    • 2005
  • Objectives: The objective of this study is to assess cognitive functions and their relationship with sleep symptoms in young narcoleptic patients. Methods: Eighteen young narcolepsy patients and 18 normal controls (age: 17-35 years old) were recruited. All narcolepsy patients had HLA $DQB_1$ *0602 allele and cataplexy. Several important areas of cognition were assessed by a battery of neuropsychological tests consisting of 13 tests: executive functions (e.g. cognitive set shifting, inhibition, and selective attention) through Wisconsin card sorting test, Trail Making A/B, Stroop test, Ruff test, Digit Symbol, Controlled Oral Word Association and Boston Naming Test; alertness and sustained attention through paced auditory serial addition test; verbal/nonverbal short-term memory and working memory through Digit Span and Spatial Span; visuospatial memory through Rey-Osterrieth complex figure test; verbal learning and memory through California verbal learning test; and fine motor activity through grooved pegboard test. Sleep symptoms in narcolepsy patients were assessed with Epworth sleepiness scale, Ullanlinna narcolepsy scale, multiple sleep latency test, and nocturnal polysomnography. Relationship between cognitive functions and sleep symptoms in narcolepsy patients was also explored. Results: Compared with normal controls, narcolepsy patients showed poor performance in paced auditory serial addition (2.0 s and 2.4 s), digit symbol tests, and spatial span (forward)(t=3.86, p<0.01; t=-2.47, p=0.02; t=-3.95, p<0.01; t=-2.22, p=0.03, respectively). There were no significant between-group differences in other neuropsychological tests. In addition, results of neuropsychological test in narcolepsy patients were not correlated with Epworth sleepiness scale score, Ullanlinna narcolepsy scale score and sleep variables in multiple sleep latency test or nocturnal polysomnography. Conclusion: The current findings suggest that young narcolepsy patients have impaired attention. In addition, impairment of attention in narcolepsy might not be solely due to sleep symptoms such as excessive daytime sleepiness.

  • PDF

A Study on Sleep Quality Algorithm by Piezo Sensor Signal (Piezo Sensor Signal에 의한 수면의 질 Algorithm에 관한 연구)

  • Byun, Jae-Ryoung;Cho, We-Duck;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.324-326
    • /
    • 2011
  • Measuring a biosignal during sleep is an important part of diagnosis and treatment of sleep disorder and also used to determine the general quality of sleep. As in current polysomnography, Contact method, which requires the attachment of electrodes to the skin, is the typical method to measure a biosignal during sleep. The procedure of this test is often considered to be inconvenient and tiresome because it requires attaching the device to the skin for each observation, and also limits free movement throughout the test. For this reason, the research on the acquiring the biosignal information without any attachment of a fixture on the skin is being conducted actively these days. In this study, it is suggested to check the heart rate per minute and the presence of breathing by placing a Piezo, which is a film type of pressure sensor, on the bed.

  • PDF

The Compliance and Effect of CPAP in Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡 환자에서 지속적 상기도 양압술의 순응도와 효과)

  • Han, Eun-Kyoung;Yoon, In-Young;Chung, Seock-Hoon
    • Sleep Medicine and Psychophysiology
    • /
    • v.13 no.2
    • /
    • pp.52-58
    • /
    • 2006
  • Objectives: Continuous positive airway pressure (CPAP) is effective in the treatment of obstructive sleep apnea syndrome (OSAS), but the major limitation of CPAP may be poor compliance. The aims of the study were to investigate the compliance and side effects of CPAP, and to evaluate the efficacy of CPAP in patients with OSAS. Methods: This study enrolled 106 patients with OSAS who took the CPAP treatment. The severity of daytime sleepiness was measured using Epworth Sleepiness Scale (ESS), and sleep quality and depressive symptoms were assessed by Pittsburgh Sleep Quality Index (PSQI) and Beck Depression Inventory (BDI), respectively. Results: During 29 months of the study period, 41.5% of patients were using CPAP and 38.7% of patients stopped using it. Compared to non-compliant patients, compliant patients had a higher PSQI score and obstructive apnea index. Among non-compliant patients, 51.2% of them stopped using CPAP within 1months. 85.7% of non-compliant patients were discomforted by the CPAP, but much more nasopharyngeal symptoms were reported in the compliant group. ESS (p<0.01), PSQI (p<0.01) and BMI (p<0.01) were reduced significantly after CPAP treatment but not BDI (p=0.86). Conclusions: We concluded that CPAP can reduce the daytime sleepiness, nocturnal sleep disturbance, and body mass index. To increase the compliance of CPAP, we suggest that some education and support are needed at the early stage of the CPAP treatment.

  • PDF

A Study of EEG and Melatonin in Plasma According to Exercise Type in Elderly with Sleep Disorder (수면장애 노인의 운동유형별 뇌파와 혈 중 멜라토닌 농도 비교)

  • Kim, Dong-Hyun;Kim, Souk-Boum
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.8 no.2
    • /
    • pp.29-37
    • /
    • 2018
  • Objective : Sleep disorder caused by stress or disease to elderly currently. We tried to make clear constant exercise according to exercise intensity would have effect on sleep disorder in elderly using EEG and melatonin. Methods : Thirty subjects were over 65 years old who lived a senior facility in some parts. They were able to communicate and understand the purpose of the study. They also expressed their intension to participate actively in experiment. They should have alert consciousness and orientation about time, place, and people. Sleep disorder was assessed via below 6 hr total sleep time and Pittsburge Sleep Quality Index, which was satisfied with both of criterion at the same time. Exercises composed of low intensity walking, moderate aerobic exercise, and high intensity resistance strength. We used QEEG 8-System (LAXTHA Inc. KOREA) to check wave type and Polysomnograpy (Compumedics, Australia) to test quality of sleep. and Histologic features were observed by TTC (triphenyltetrazolium chloride) staining and H & E (Hematoxylin & Eosin) staining. Results : There was a significant sleep index and change of melatonin after aerobic exercise. There was a significant SOL, S1, S2, and SWS in aerobic exercise, but there was a significant SWS in walking and resistance strength. There was a significant change of delta wave especially in frontal and temporal region between exercises. Conclusion : They had different effects according to type of exercise, when elderly who have chemical, behavioral change of circadian rhythms did exercise consistently. Aerobic exercise had more effect on sleep disorder than other exercise. Therefore, we may supply proper exercise to elderly and high quality of life.