  • The radiation has been utilized in a number of fields, even though the use of plenty cause a variety of side effects. This study was confirmed for radiation protective effects of aged garlic to contribute to the prevention of disasters that are radiation exposure. We studied the Complete Blood cell Count(CBC) and the small intestine after feeding aged garlic extract into Sprague Dawley Rat which irradiated X-ray beam 7 and 13 Gy. Garlic extract was administered to the results in the experimental group showed a notable difference in the CBC of platelets (p<0.05), red blood cells (p<0.05) and early damaged white blood cells (p<0.05). In addition, it was confirmed that experimental group's small intestine crypt is more survival than irradiation group significantly. And experimental group has small intestine villi length almost similar to the normal group. result of the aged garlic study will be able to be of great benefit for the radiation relevant emergency management.

An Experimental Study on Ground Reinforcement Effect of Concrete and Expansion Mat for Prevention of Buried Pipe Damage (지중매설관 손상 방지를 위한 콘크리트매트와 팽창매트의 지반보강효과에 관한 실험적 연구)

  • Park, Jeong-Jun;Shin, Heesoo;Yuu, Jungjo;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.1
    • /
    • pp.91-101
    • /
    • 2019
  • Recently, small-scale excavation like ground cavity restoration and buried pipe replacement works are being carried out in urban area, in order to improve living convenience. This paper describes experiment results on the ground reinforcement method that can reduce the buried pipe damage, when the differential settlement occurred due to poor compaction of ground below the buried pipe. Plate load tests were conducted to evaluate a reinforcement effect of ground using concrete mat and expansion mat in the ground below the buried pipe. The results showed that the stress reduction ratio by concrete mat and expansion mat according to the surcharge load was about 46%~48% and 39%~42%, respectively. Therefore, the differential settlement of the buried pipe and the ground deformation below the buried pipes were reduced by the reinforcement effect of the concrete mat and expansion mat. This means that it is possible to prevent a buried pipe damage due to underground cavity and ground subsidence, if concrete mat and expansion mat are reinforced in the ground below the buried pipe or on the ground between the buried pipes.

Antibacterial Mechanism and Salad Washing Effect of Bitter Orange Extract Against Salmonella Typhimurium (광귤 추출물의 Salmonella Typhimurium에 대한 항균 메커니즘 및 샐러드 세척 효과)

  • Yoon-Mi Ji;Ji-Yun Bae;Chung-Hwan Kim;Se-Wook OH
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.3
    • /
    • pp.273-280
    • /
    • 2024
  • In this study, the antibacterial activity and mechanisms of bitter orange extract, a natural antibacterial agent, were investigated, with a focus on its potential application in washing water for controlling Salmonella Typhimurium contamination of salad, a ready-to-eat food. The minimum inhibitory concentration (MIC) of bitter orange extract against S. Typhimurium was determined using the broth dilution method. Subsequently, S. Typhimurium was exposed to various concentrations of bitter orange extract (1/16 MIC-2 MIC) and growth curves were measured. Following treatment with bitter orange extract, we investigated its antibacterial mechanism by measuring intracellular reactive oxygen species (ROS) levels, alterations in membrane potential and integrity, and nucleic acid leakage in S. Typhimurium. Additionally, salads artificially contaminated with S. Typhimurium were treated with different concentrations of bitter orange extract using the dipping method for various durations to assess the reduction effect. The MIC of bitter orange extract against S. Typhimurium was 195.313 mg/L, and bacterial growth was completely inhibited at a concentration of 1 MIC. Furthermore, an increase in bitter orange extract concentration correlated with elevated intracellular ROS levels, membrane potential disruption, membrane damage, and nucleic acid release. Importantly, salads treated with bitter orange extract exhibited a significant reduction in S. Typhimurium counts compared to the control, and prolonged treatment times resulted in further reductions in bacterial counts. Bitter orange extract was more effective than sodium hypochlorite and can be used as a safer salad wash. These findings indicate the potential treatment of salads to prevent foodborne illnesses.

Conservation of the Seosanmaaesamjonbulsang (Rock-carved Triad Buddha in Seosan), Korea (서산 용현리 마애여래삼존상의 보존처리)

  • Min, Won Geun;Jong, Hee Su;Yang, Hee Jae
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.73-86
    • /
    • 2014
  • The Seosanmaaesamjonbulsang (national treasure 84) is carved has a quite developed tectonic line in a precipitous wall of stratified rock to the vertical and horizontal directions. The main buddha and the left part of it have got the biological weathering and the efflorescence has been detected on the shoulder part of the right buddha. It has been caused by the raindrops from upper rock after the dismantling of the protection shelter in 2007. Two proper measures have been taken in order to reduce the weathering and protect it from some damages. The one is removing the contaminant by dry/wet cleaning not to get any damage on the rock. The other is the isolation by the construction of a new waterway used L-30 on the upper part of the rock not to contaminate the surface of Rock-carved triad buddha with the raindrops from upper rock. Moreover, the sunlight for buddha has been increased and good ventilation has been made by cutting down the trees around the Rock-carved triad buddha.

  • PDF

Study on Hydrate Kinetic of $CH_4+CO_2$ and $CH_4+CO_2+N_2$ System ($CH_4+CO_2$ System과 $CH_4+CO_2+N_2$ System의 Hydrate Kinetic 비교 연구)

  • Shin, Hyungjoon;Moon, Donghyun;Han, Kyuwon;Lee, Jaejung;Lee, Juho;Yoon, Jiho;Lee, Gangwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.219.1-219.1
    • /
    • 2010
  • 매립지에서 유기물의 분해로 발생되는 매립가스는 악취 등으로 인한 대기오염뿐만 아니라 온난화지수가 21인 메탄이 약 50vol% 포함되어 있어 지구온난화에 큰 영향을 미친다. 하지만 매립가스를 에너지원으로 활용하면 대기오염저감, 지구온난화 감소, 대체에너지원 확보뿐만 아니라 CDM사업 등과 연계하여 부가수익창출이 가능하다. 현재 국내에는 약 242개의 폐기물매립지가 있는데, 이중 매립가스를 활용하는 곳은 단지 14개소로 개별 경제성이 있는 대형매립지에서만 자원화시설을 설치하여 운영 중이며 그 외 매립지에서는 매립가스를 소각 또는 단순 대기 방출하여 대기오염유발과 동시에 대체에너지원 미활용으로 국가차원에서 큰 손실이므로 이를 활용할 수 있는 기술개발이 시급하다. 본 연구에서는 중소규모 매립지에서 발생하는 매립가스를 중심적환장으로 이송하여 경제성을 가지는 에너지원으로 활용할 수 있는 기술개발을 목표로 하이드레이트 기술을 접목한 기초연구를 수행하였다. 매립지에서 매립가스가 생성되는 과정에 표층부의 균열 및 차수막의 손상과 포집하는 공정에서 블로워 등의 사용으로 질소가 다량 포함되며 질소의 경우 상당히 높은 압력과 낮은 온도에서 하이드레이트를 형성하므로, 매립가스 하이드레이트 형성시 질소의 영향에 대해 알아보았다. $CH_4+CO_2$ System과 $CH_4+O_2+N$ System에 대하여 각각의 실험조건에서 Kinetic을 측정하였으며, 실험전후의 가스 조성을 Gas Chromatography로 정성, 정량 분석하였다. 실험결과 매립가스에 공기가 유입될 경우, 질소의 영향으로 하이드레이트 생성조건이 가압되었고 하이드레이트 내 메탄의 함량비율이 줄어들었다.

  • PDF

Development and Application of Backfill Material for Reducing Ground Subsidence (지반함몰 저감을 위한 하수관로 뒤채움재 개발 및 현장적용성 평가)

  • Lee, Dae-Young;Kim, Dong-Min;Ryu, Yong-Sun;Han, Jin-Gyu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.147-158
    • /
    • 2015
  • In this study, sewer backfill material was developed to prevent sewer damage and ground subsidence. Laboratory test was performed in the field of CA replacement ratio, accelerator type and replacement ratio and W/M. The compression strength of backfill material was 0.55~0.64MPa below in W/M 70% and 0.20MPa over W/B 80%. Ice block was used to simulate the ground cavity and subsidence caused by sewer damage in application study. The existing sand compaction and the new backfill material was comparative estimated in field. The ground settlement of cross section was 23.4cm and that of longitudinal section was 27cm in sand compaction section, but the ground had not sunk in backfill material section.

Performance Characteristics with Various Fuel Composition and Temperature for an External Type Fuel Pump in LPLi System (LPLi 시스템에서 외장형 펌프의 연료조성 및 온도에 따른 성능특성 연구)

  • Nam, Deok-Woo;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.566-575
    • /
    • 2011
  • Since LPG (Liquefied petroleum gas) fuel supply system has an advantage of low emission characteristics, many studies have been conducted. In spite of the advantage of LPG supply system, a higher vapor pressure and lower viscosity than diesel or gasoline fuel may cause unstable running of fuel pump by the deterioration in lubrication performance and chemical reaction with rubber parts than that of diesel and gasoline fuel. Therefore its physical properties can cause the deterioration of durability. In this research, we developed an external type LPG pump which has the advantage of the price competitiveness and the convenient maintenance for LPLi system. The experiments were carried out in order to assess characteristics of the external type fuel pump at different fuel composition and temperature. As a result, there aren't any differences between internal and external type pump performance. It is observed that the same level of efficiency was maintained for both pumps as flow rate was increased with higher fuel temperature and more contents of propane in the fuel. And the pressure difference in LPLi system is maintained at constant with the various fuel compositions and temperatures due to their own characteristics of fuel supply system.

Static Experiment of Reinforced Concrete Frame Retrofitted with Steel Damper System (강재댐퍼시스템으로 내진보강된 철근콘크리트 골조의 정적가력실험)

  • Baek, Eun Rim;Lee, Sang Ho;Oh, Sang Hoon;Kim, Jae Bong
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.90-90
    • /
    • 2011
  • 최근 전 세계적으로 지진의 발생 빈도가 증가하며 그 규모도 점차 커지는 경향을 보이고 있다. 대형지진의 발생 시 저층 구조물의 붕괴로 인한 인명 및 사회, 경제적 피해가 두드러짐에 따라 기존 저층 구조물의 내진보강기법에 관한 연구가 활발히 진행 중인 추세이다. 우리나라의 경우 강도증가형 내진보강공법이 주를 이루고 있어 다양한 내진보강기법의 개발 및 적용이 필요한 실정이다. 따라서 본 연구에서는 지진입력하중 저감형 내진보강기법으로서 강재댐퍼시스템을 제안하여 구조적 성능을 파악하고, 이를 적용한 보강 실험체와 비보강 실험체를 제작하여 정적가력실험을 통하여 그 성능을 비교하였다. 제안된 강재댐퍼시스템은 입력에너지를 소산시키는 내부의 슬릿형 댐퍼와 이를 지지하는 기둥 및 외부 프레임으로 구성되며, 내부 댐퍼는 먼저 항복하여 에너지를 소산시키기 위하여 지지기둥 및 프레임에 사용된 강재보다 강성 및 강도가 적게 계획되었다. 강재댐퍼의 성능실험 결과, 비교적 안정적 거동을 하며, 강성과 강도 및 에너지 흡수능력이 우수하게 나타났다. 보강 및 비보강 실험체의 골조는 기존 학교 건축물의 표준도면을 기준으로 하여 골조의 일부를 대상으로 60% 축소율을 적용하여 계획하였으며, 보강 실험체는 미리 제작된 강재댐퍼시스템을 골조 내에 설치하여 에폭시 주입법으로 부착시공 하였다. 보강 및 비보강 골조 실험체의 정적가력 실험결과 비보강 실험체는 기둥의 휨 항복 후 변형의 증가에 따라 휨 및 전단 균열이 증가하면서 최종적으로 기둥이 전단파괴 되었으며, 보강 실험체는 비보강 실험체에 비하여 기둥 및 보의 균열이 적고, 골조에 골고루 분포되어 파괴 규모가 감소하였다. 최대 강도면에서 보강 실험체는 비보강 실험체에 비하여 약 3.4배 우수하였으며, 초기강성은 약 7배 가량 유리한 것으로 평가되어 제안된 강재댐퍼시스템이 강도면에서 우수한 성능을 나타냄을 알 수 있었다. 또한 두 실험체의 기둥 주근 및 띠철근의 변형률을 비교한 결과, 비보강 실험체는 대부분의 철근이 항복하여 큰 변형을 일으킨 반면, 보강실험체에서는 철근의 항복현상이 나타나지 않았고 댐퍼가 항복을 하면서 큰 변형을 일으켰다. 이를 통해 지진하중 입력 시 댐퍼에서 입력 에너지를 흡수하여 큰 하중을 부담하며, 기존의 구조부재에는 입력 에너지가 낮아 손상이 보다 적게 발생함을 확인하였다.

  • PDF

A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coil (초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.96-101
    • /
    • 2007
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for communication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the sparkover voltage required to initiate the discharge process in the GDTs and the time taken for arc formation process can be large enough to damage to sensitive circuits. For GDTs with a considerably high initial residual voltage, we should limit the peak voltage using a TVS or filter. We made a hybrid SPD circuits of common-mode type and differential-mode type with the filter using common-mode choke. Also, we applied lightning impulse voltage and ring wave voltage which frequency bandwidth are different each other and verified the characteristics of hybrid SPD circuits according to waveshapes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurement at each step. The experiment results show that the surge voltage reduction with the choke coil is more effective in differential-mode circuit than in common-mode circuit.

Evaluation of the Protection Performance of TT and TN Systems for Low-Voltage Consumers Against Lightning Surges (저압수용가에 공급하는 TT, TN계통의 뇌서지에 대한 보호성능의 평가)

  • Lee, Kyu-Sun;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.67-74
    • /
    • 2010
  • Most of domestic low-voltage consumers are supplied from the TN-C system of KEPCO, but their load installations have established according to the national statutory standard for electrical installations based on the TT system. In this work, to propose the proper system earthing arrangements of ensuring the protection of information-technology equipment against lightning surges, the protection performance of TT and TN systems against lightning surges was investigated. As a result, when lightning surge was injected to the neutral line of distribution system, the potential difference between the equipment earth terminal and neutral point of low-voltage mains in a TT system was significantly raised. The TT system is not advised due to the risk of damage to the sensitive computer equipment. Main equipotential bonding is an important requirement for protection of low-voltage installations against lightning surges. The TN system provides the best means to reduce the incoming lightning surges through the neutral line of low-voltage service systems. In addition, It is highly recommended to install the additional earthing at the service position of low-voltage consumers.