• Title/Summary/Keyword: 소음 규명

Search Result 380, Processing Time 0.024 seconds

Sound Source Investigation of Outer Rotor BLDC Motor (외부회전자형 BLDC 전동기의 소음원 규명)

  • Lee, Chang-Min;Woo, Ho-Kyun;Moon, Jung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.463-468
    • /
    • 2011
  • According to a quantum leap of the performances of automobile, environmental factors are important as functional factors, especially noise. BLDC motor, one of the part of automobile, is also no exception. In this paper, investigation of the sound sources of outer rotor type BLDC motor is performed. In order to reduce noise, it must be necessary knowing sound source. To this end, this paper is analyzed two viewpoints, structural and electromagnetic causes. For structural analysis, modal experiment and 3D mode analysis are performed. On behalf of electromagnetic analysis, 2D finite element method is carried out. Finally, coupling analysis is performed in order to know about influence between two factors.

  • PDF

Root-Cause Investigation of Abnormal Sound from a Heat Exchanger of Condensate Water System in a Nuclear Power Plant (원전 복수계통 열교환기의 이음발생 원인규명)

  • Lee, Jun-Shin;Kim, Tae-Ryong;Lee, Wook-Ryun;Sohn, Seok-Man;Yoon, Seok-Bon;Kim, Man-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1306-1311
    • /
    • 2006
  • The root cause of abnormal sound from a heat exchanger of condensate water system in a nuclear power plant is investigated by using the impact signal-processing methodology based on the Hertz theory. The predicted results for the location of impact force and the loose part size meet good agreement with the identified materials during the overhaul period in the plant. Nuclear power plants have experienced several loose parts and the frequency of the loose part will be increased along the aging of the plants. So, this analysis methodology for the impact signal will be widely utilized for the primary and secondary side of the nuclear power plant.

  • PDF

Development and Application of Measuring Method for Instantaneous Intensity (순시 인텐시티 측정 기법의 개발 및 응용)

  • 이장우;안병하
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.960-963
    • /
    • 2003
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these state, select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

The search for relations betwwen compressor noise and refrigerator noise (압축기소음과 냉장고소음의 관계 규명 (압축기 정음화에 의한 냉장고 정음화))

  • 유원희;백충국;송진환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.32-36
    • /
    • 1996
  • Noise radiated from refrigerator is mainly decided by compressor noise. If the compressor is silent then the refrigerator could be silent. But In some case this tendency is not true. Because there is uncertain relations between compressor noise and refrigerator noise. And the refrigerator noise is affected by the cycle-matching in the refrigerating system using compressor. In this research it was studied that the compressor noise which didn't affect some refrigerator models could affect other refrigerator models. The methods which could reduce the refrigerator noise was studied and ultimately the methods which could change the characteristics of compressor noise was presented.

  • PDF

Source Identification in an Interior Sound Field (실내 공간에서의 음원 탐지 방법)

  • 김양한;최영철
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.7
    • /
    • pp.520-526
    • /
    • 2002
  • Identification of noose sources, their locations and strengths, has been taken great attention. The methods that can identify noise sources normally assume that noise sources are located in a free field. However, the sound in a reverberant field consists of that coming directly from the source plus sound reflected or scattered by the walls or objects in the field. In contrast to the exterior sound field. reflections are added to sound field. Therefore, we haute to consider the reverberation effect on the source identification method. The main objective of this paper is to identify noise source in the reverberant field. At fist, we try to identify noise sources in a rigid wall emc;psire using the beamforming method. In many cases of practical interest, the wall has admittance so that random reflections occur in an enclosure. In this paper, we assumed the complex reverberant field in the enclosure to be the sum of plane caves with random Incidence and magnitude. Then we try to explain effects of reverberant field at interior source identification.

Acoustic Mode Analysis to Identify Cavity Noise of Scroll Compressor (스크롤 압축기의 공동 소음 규명을 위한 음향모드 분석)

  • Kim, Seung-Yup;Lee, Dong-Soo;Suh, Jeong-Hwan;Heo, Dae-Nyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.83-88
    • /
    • 2004
  • Acoustic modes of internal region of 4-hp scroll compressor are identified by measuring transfer functions between a reference and 84 measuring points. The corresponding acoustic mode-shapes and natural frequencies were calculated by analysis software SYSNOISE. There exist two clearly distinguishable dipole modes of vertical and horizontal direction and a single quadrupole mode in the frequency region of interest. It shows that the natural frequencies of the identified modes are linearly sensitive to suction pressure (Ps) but relatively in sensitive to discharge pressure (Pd) in operating condition.

  • PDF

A study on the Characteristics of a Centrifugal Fan Vibration and Noise (Centrifugal Fan 송풍기의 진동.소음 특성에 관한 연구)

  • 김태형;김옥현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.999-1003
    • /
    • 1992
  • Because of low noise and small size with huge capacity, a centrifugal fan is widely used for ventilation, air-conditioner and so on, which are very near to human life. Because of the complexity of its vibration and noise generation mechanics, most of researches on them are based on experimental methods. This study is to characterize the centrifugal fan noise and vibration. It is considered that noise is composed of the structural vibration noise and the air flow induced aerodynamic noise. To decouple the structural vibration noise the centrifugal fan is masked with an adhesive tape, such that air blowing is prohibited thus only the structural vibration noise is extracted. The noise level and characteristics in the frequency domain are verified and compared with those of total mixed one. This study shows some significant results that the structural vibration noise has relatively narrow band power spectrum compared with the total mixed one and has a strong periodicity. The sound level is lowered about 5dB by the removal of air flow with the masked fan for an air-conditioner used in this study.

Towards reducing acoustical high-frequency noise of a direct current relay via contact structure (직류 계전기의 접촉구조에 의한 고주파수 소음저감)

  • Junhyeok, Yang;Jongseob, Won;Wonjin, Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.691-697
    • /
    • 2022
  • In this work, a straightforward component design of a direct current (DC) relay equipped in electric vehicles is discussed. The work aims to provide and evaluate effective measures for reducing high-frequency sound from the DC relay carrying electric power. From the operation experiments for the relay, it is observed that noise is caused by the resonance from the forced vibration by the electromagnetic repulsive force originating at the area of electric contacts with a resonance frequency of around 710 Hz ~ 730 Hz. A finite element model for the relay was established to conduct vibration mode analysis, consisting of stationary and movable contacts and a contact spring. Vibration mode analysis indicates that in the resonance frequency, the movable contact with two-point contacts experiences rotational vibration mode. For the proposed relay with a three-point contact, vibration mode analyses give reasonable results of reducing noise at that frequency. Furthermore, for the fabricated relays with the three-point contact, similar results have been obtained. In conclusion, one can see that the proposed measures provide one of the feasible solutions to the reduction of relay noise.