• Title/Summary/Keyword: 소음 감소기

Search Result 117, Processing Time 0.041 seconds

Research of Noise Reduction about Excavator Return Line (굴삭기 리턴 라인 유동소음 감소에 관한 연구)

  • Kang, B.I.;Jang, D.S.;Kim, S.J.;Kwon, Y.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.2
    • /
    • pp.7-13
    • /
    • 2006
  • In this paper the noise source and the amplifying mechanism are analyzed to reduce the noise of the excavator return line using the experimental approach and the CFD simulation. The result says that the reason of noise generation is pipe vibration caused by the cavitation at the main control valve and the level of noise is proportional to the valve back pressure at the return line. The methodology to reduce this noise was proposed and verified by the vehicle test.

  • PDF

Vibration Reduction of Steel Hot-Rolling Facility (제철 열간 압연기의 진동 저감책)

  • 노용래
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.65-70
    • /
    • 1993
  • 본 연구에서는, 제철 열간 압연기에서 slab가 진입, 추출시 충격으로 인한 진 동에 의해 두께 조절용 위치센서가 오작동을 하는 원인을 규명하고 그 해결 책을 제시하고자, 기존 AGC Top Plate와 위치 감지센서의 작동 상태 및 진 동특성을 검정하였고, 문제점을 발견하여 각각의 구조를 개선, 재측정하여 개선정도를 확인하였다. Disk형 AGC Top Plate는 직경을 줄이고, 두께를 늘 여 자체 진동을 감소시켜, Plate 진동에 의한 위치센서의 오작동 원인 및 이 에 의해 제어 유압펌프에 Feedback되어 top부 제어계에 발생하는 Hunting현 상을 줄였다. 위치센서는 내부 Spring의 초기변형량을 증가시켜 내탄성에너 지량을 증가시켜, 센서자체의 진동 및 측정시 나타나는 여진현상을 제거하였 다. 본 연구를 통한 측정결과로는 최대 82.7%의 제진효과와 여진현상의 제거 효과를 보았다.

  • PDF

Design/Manufacturing/Test of Curved Actuator LIPCA Composed of Piezoelectric Ceramic and Fiber Composite Layers (압전 세라믹과 섬유복합재료 층으로 구성된 곡면형 경량 작동기 LIPCA의 설계/제작 및 성능시험)

  • Sin, Seok-Jun;Kim, Ju-Sik;Gu, Nam-Seo;Park, Hun-Cheol;Gwak, Mun-Gyu;Yun, Gwang-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1268-1272
    • /
    • 2000
  • 본, 논문에서는 카본/에폭시, PZT 세라믹 박판, 글래스/에폭시 층으로 이루어진 곡면형 복합재료 작동기(LIPCA)의 설계, 제작 및 성능실험에 대한 연구 성과를 제시하고 있다. LIPCA의 큰 요점은 기존 THUNDER의 성능을 유지하면서 이를 경량화 하기 위하여 THUNDER의 금속 층을 상대적으로 가벼운 섬유 강화 복합재료로 대체하는 것이다. 이러한 경량화 작업으로 LIPCA는 기존 THUNDER 보다 약 $30{\sim}40%$ 정도의 무게를 감소시킬 수 있으며, 복합재료의 특성에 따라 설계의 유연성을 가질 수 있는 장점이 있다. 또한, 에폭시 수지를 사용함으로써 접착제 없이 평판 몰드에서 오토클레이브에서 $177^{\circ}C$로 경화되어, 탈형된 후 충분한 곡률을 형성하였다. 작동 성능 실험에서, LIPCA는 기존 THUNDER보다 작동변위가 향상됨을 보였다.

  • PDF

Design of Virtual Engine Sound System for Green Car (그린카 가상 엔진음 발생기 설계)

  • Kwak, Bum-Moon;Son, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.93-94
    • /
    • 2015
  • 본 논문에서는 전기자동차의 주행에 있어 발생되는 소음이 아주 적다는 장점이 보행자들에게 있어서는 차량이 접근하고 있다는 인지능력을 감소시키는 단점으로 발생된다. 따라서 인위적인 가상의 엔진음을 발생시켜 보행자들로 하여금 차량이 접근하고 있다는 인지능력을 향상시키기 위한 전기자동차 가상 엔진음 발생기 설계에 대한 연구내용 및 방법을 제시한다. 이 시스템은 전기자동차의 전원이 ON됨과 동시에 동작하여 가상의 엔진음을 발생시키고 적정 거리의 보행자도 무리없이 소리를 인지하여 차량의 접근을 인지할 수 있도록 하여 보행자의 안전을 보장하기 위한 시스템 개발이 최종 목적이다.

  • PDF

열린 박스 구조물에 대한 적응형 PPF 제어

  • 정환수;윤영동;신윤덕;기창두
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.109-109
    • /
    • 2004
  • 구조물에 있어서 진동은 소음을 유발하며 구조물을 불안정하게 만드는 요인이 된다. 특히, 저주파 진동은 구조물에 미치는 영향이 크므로, 유연구조물의 저주파 진동모드들을 우선적으로 제어할 필요가 있다. 본 논문에서는 압전세라믹을 작동기로, 압전필름을 감지기로 사용하였고, 능동 제어 알고리즘의 하나인 적응형 디지털 PPF(Positive Position Feedback) 제어기를 구성하여 유연 외팔 평판과 열린 박스 구조물에서 저주파 진동을 감소시켰다.(중략)

  • PDF

Design of adhesive wireless bookbinding machine with optimal motor control and automatic cover insertion (최적의 모터 제어 및 겉표지 자동 투입 기능을 적용한 접착식 무선 제본기 설계)

  • Song, Je-Ho;Lee, In-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.198-203
    • /
    • 2019
  • An adhesive wireless bookbinding machine was designed with optimal motor control and automatic cover insertion for bookbinding. The noise level was improved by modifying the thrust of the machine and changing from a compressor method to an AC induction motor control method. The automatic cover insertion function was added to improve the task speed. Motor and decelerator damage can be caused by sudden braking and acceleration of the motor rotation (clockwise and counter-clockwise), so a buffer-type locational control system was developed to secure stable movement and durability. The complicated internal design was also simplified, and the volume and weight were decreased. The results show that the noise was decreased by 57% from 135 dB to 71.7 dB, and the task speed was decreased by 57% from 18 s to 9.58 s. The automatic cover insertion was designed to supply a maximum of 130 sheets per supply.

Study on Elevator Induced Structural Vibration Reduction Performance Using Polymer Concrete (폴리머 콘크리트를 이용한 엘리베이터 기인 구조 진동저감 성능 연구)

  • Yeom, Jihye;Kim, Jeong-Jin;Park, Junhong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.90-94
    • /
    • 2021
  • With the increased interest on quiescent place for residential place, the noise generation from facilities needs to be minimized. One important noise source include sounds from operation of elevators. The elevator operates between floors and generates significantly annoying sounds to the nearby living spaces. It is recognized as the significant contributor inducing noise annoyance to residents. Elevator is supported to the building structure at several locations for movements between floors. In this study, the vibration reduction by use of polymer concrete on the support location was demonstrated. By measuring and comparing the vibration generation when supported on cement and polymer concrete, the noise reduction performance was evaluated. The polymer concrete was made in the form of being inserted into the wall that imitates the hoistway. The impact vibration was induced to the bracket and vibration transfer magnitude was measured. The damping ratio was evaluated through normalization and curve fitting of transient response, and comparison was performed for each resin mixing ratio. By use of polymer concrete, it was possible to reduce the vibration generation in an effect manner without sacrifice on the structural rigidity.

The Effect of Textile Industry on the Workers' Blood Pressure (섬유공장(纖維工場)의 소음(騷音)이 근로자(勤勞者)들의 혈압(血壓)에 미치는 영향(影響))

  • Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 1984
  • To assess the effect of noise on the blood pressure of workers, 70 weaving and 70 refining female workers in 15 to 24 years of ages were tested for the changes of blood pressure before and after exposure to the noise. The noise levels at work place were 99 dB (A) for weavers and 80 dB(A) for refiners. The mean age of refiners was 17,7 years and that of weavers was 18.6 years, and the difference in mean ages was statistically significant (p<0.05). The means of heights, weights and working durations were not significantly different between two groups. The mean systolic blood pressure of the weavers was 112.5mmHg before exposure to the noise and it was increased to 115.7mmHg after exposure to 99 dB(A) of noise for 30 minutes, and the mean diastolic blood pressure from 71.6mmHg to 74.1mmHg. These increments of blood pressure were statististically significant (p<0.05). The mean systolic blood pressure of the refiners was decreased from 108.9mmHg to 106.7mmHg after exposure to 80 dB(A) of noise for 30 minutes, and the mean diastolic blood pressure from 67.3mmHg to 67.1mmHg. These changes of blood pressure were not statistically significant. The mean systolic and diastolic blood pressure of the weavers before exposure to the noise were significantly higher than that of refiners (p<0.05). The difference of blood pressure between refiners and weavers was significantly associated with noises (p<0.05), and not ages and their interactions. The study results support the hypothesis that exposure to excessive noise increases the blood pressure of workers.

  • PDF

공조기용 열교환기

  • 윤정인
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.10
    • /
    • pp.47-51
    • /
    • 2000
  • 최근 룸에어콘이나 패키지에어콘의 에너지 절약, 쾌척성 등에 대환 사용자나 회사로부터의 요구는 더더욱 높아지고 있다. 공조기의 중요한 구성요소 중 하나인 열교환기도 이러한 요구에 대응하여 기술개발이 계속해서 진행되고 있다. 공조용 열교환기를 설계할 때 가장 중요한 과체는 비용이냐 설치성 등의 제약조건올 만족하면서 필요한 교환열량을 달성하기 위해, 요구되는 열 전달계수(K)와 전열면적(A)의 곱인 KA값을 얼마나 확보하는가 하는 점에 있다. 그러나 이 외의 과제, 예를 들어 홴입력, 소음을 억제하기 위한 공기측 통풍저항의 감소, 증발온도에 영향을 마치는 관내압력손실의 감소 등도 중요한 과제이다. KA값 증대와 통풍저항억제를 동시에 판촉하기 위해 공조용 열교환기는 전면면적을 크게 하고 두께를 작게 하여 사용하는 것이 원칙이다. 또, 전열관의 관경도 관 둘레길이와 냉매분배성능 면에서 제약이 발생한다. 이와 같은 배경으로부터 공조용 열교환기는 판경 6~10 mm정도의 전열 관을 20~25mm길이로 배치한 핀튜브형 열교환기가 주류로 되어있다. 여기에서는 공조기에 널리 사용하고 있는 핀튜브형 열교환기에 대한 최근의 기술개발 사례를 소개하고자 한다.

  • PDF

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.