• Title/Summary/Keyword: 소음기준치

Search Result 44, Processing Time 0.026 seconds

Tunnel Blasting case by Combination of Electronic Detonator and Non-electric Detonator (전자뇌관과 비전기뇌관을 조합한 터널발파 시공사례)

  • Lee, Min Su;Kim, Hee Do;Lee, Hyo;Lee, Jun Won
    • Explosives and Blasting
    • /
    • v.36 no.1
    • /
    • pp.34-38
    • /
    • 2018
  • It proceed the trial test by applying blasting system with combination of electronic detonator and non-electric detonator(Supex Blasting Method) for the purpose of preventing the over-break as well as controling the blasting vibration and noisy at the site of Boseong-Imseongri railroad section ${\bigcirc}{\bigcirc}$. As a result of that, the blasting vibration and noisy was measured within the allowable standard of vibration. In conclusion, the combination of electronic detonator and non-electric detonator can not only reduce come construction cost, level of vibration and noisy but also get the prevention effect for Public resentment and minimize the rock-damage through over break control.

Performance Evaluation Based on Low-Noise Asphalt Pavement Use (저소음 아스팔트 포장 공용에 따른 성능평가)

  • Hwijae Shin;Sungho Mun
    • Land and Housing Review
    • /
    • v.15 no.3
    • /
    • pp.165-175
    • /
    • 2024
  • As living standards improve, the demand for quiet and comfortable environments is increases. However, noise sources are rising due to population growth, urbanization, and industrialization. One solution to this problem is low-noise asphalt pavement, which has fewer installation regulations and can reduce noise at the source. Despite its advantages, there are few evaluation cases and no domestic guidelines for low-noise asphalt pavement. This study aims to evaluate the overall performance of low-noise asphalt pavement on roads in Seoul, focusing on average noise levels, skid resistance, and permeability. Noise measurements were conducted using a digital noise analyzer according to the Ministry of Environment's standards. Results indicated that noise reduction was maintained for 1 to 2 years but decreased over time. Skid resistance, assessed with the British Pendulum Tester, showed excellent performance with values above the standard of 57 in the initial stages after paving. Permeability, evaluated using the KS F 2394 method, was initially effective across all sections but declined over time.

Active Noise Control in Ductilike System using Adaptive Filtering (적응필터링에 의한 덕트계의 능동소음제어)

  • 이태연;김상명;송원식;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.17-22
    • /
    • 1991
  • 최근 기계장치로부터 발생하는 소음을 감소시키는 새로운 방법으로서, 능동 적으로 소음을 제어하는 방법에 대한 연구가 활발히 진행되고 있다. 이것은 원하지 않는 소음을 그 신호의 역위상을 갖는 부가음을 이용하여 능동적으 로 감쇠시키는 방법으로서, 저주파수 대역에서 비효율적인 수동적인 방법인 소음기둥에 대한 대안으로 많은 학자들의 관심의 대상이 되어 왔다. 초기에 는 소음을 줄이기 위해 요구되는 여러가지 음향요소의 전달함수를 제어하는 데 대한 불가능성으로 인해 능동 소음제어에 대한 실질적인 발전이 지연되 어 왔으나 최근 마이크로 컴퓨터를 비롯한 전자공학의 발전으로 인해 적응 신호처리 분야가 등장하게 되었으며, 음향계의 소음을 원하는 수준까지 제어 하는 능동 소음제어의 실시간 구현이 가능하게 되었다. 그 중에서도 음이 1 차원적으로 전파한다고 볼 수 있는 길이가 긴 덕트구조물에서의 능동 소음 제어는 가장 기본적이며 현실적으로 자동차 배기계나 냉동.공조설비에 있어 서 실용적으로 적용할 수 있는 문제임 만큼 많은 연구가 이루어지고 있다. 이러한 능동 소음제어 방법을 음향계에 적용하였을 때, 부가적인 음을 발생 하는 제어용 스피커로 인해 입력마이크로폰으로의 음향궤환이 존재하고 이 에 따라 제어계가 불안정해질 수 있으며, 또한 변환기의 사용으로 인한 부가 적인 전달함수가 존재하므로 이에 대한 중요한 의미를 갖고 고려하여야 한 다. 본 연구에서는 적응 필터링 이론에 의한 소음원의 입력신호에 대한 최적 한 예측으로써 부가음을 발생시키고, 입력신호 및 제어된 출력신호간의 차인 오차를 최소화 시키도록 하는 오차적응제어법을 이용한 능동소음 제어 방법 을 제시하였다. 이와 아울러 제어계의 환경변화에 따른 파라메타의 변화에 적응적으로 응답이 가능해야 하는 적응 소음제어 시스템에서, 음향궤환과 함 께 필히 고려해야 하는 부가적인 전달함수의 영향을 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field

  • PDF

Introduction and Preliminary Design of Floating Slab Track for Rapid Transit Railway (고속철도용 플로팅 슬래브 궤도의 도입과 기본설계)

  • Kim, Yong-Jae;Lee, Eun-Ho;Park, Myoung-Gyun;Moon, Je-U;Park, Man-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.141-144
    • /
    • 2008
  • Recently, railway has been pointed to the efficiency of transportation, rapid transit, and comfortable train ride. the construction of railway near the downtown area and station building are increasing for maximization of utilization and convenience. but the heavy of transportation and rapid transit lead to increase noise and vibration. the noise and vibration of railway may cause the civil appeal, decline in the serviceability and insufficiency of environmental standard. Therefore, the solution to avoid environmental matters becomes one of the most important factor in constructing railway. In this study, floating slab system which is one of the solution to avoid noise and vibration in railway has been introduced, and the concept of preliminary design and vibration absorber of floating slab system according to the isolator has been introduced.

  • PDF

Assessment of Dental Noise Environment of a Pediatric Dentist (소아치과의사의 치과 소음 환경에 대한 평가)

  • Cho, Hyeonmin;Kim, Ik-Hwan;Cho, Seunghyun;Song, Je Seon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.209-220
    • /
    • 2021
  • The noise is defined as unwanted sound that causes discomfort and physical changes. This study was conducted to evaluate intensity of noise in the pediatric dental clinic and to investigate noise environment of a pediatric dentist. Human ear shaped microphone and mobile noise level meter were used for recording noise and calculating intensity of noise. By recording according to the method specified by Korea Occupational Safety and Health Agency (KOSHA) of Korea Ministry of labor and employment, the following results were obtained. For 16 experimental days, 8 hour time weighted average (8hr-TWA) was 49.33 dBA (A-weighted deci-Bell) on daily average with maximum 58.54 dBA and minimum 33.97 dBA. And Dose was 0.49% on daily average with maximum 1.28%, minimum 0.04%. These values are less than criteria of KOSHA standard (85 dBA, 100%). Comparing the highest noise level for each patient, pulp therapy group and Frankel grade I group were the highest. The intensity of dental noise of pediatric dental clinic didn't meet standard of KOSHA. It is necessary to re-evaluate noise environment by establishing new standards considering environment of pediatric dental clinic.

A Study on the Cause of Noise and Vibration of an Elevator (엘리베이터 소음 및 진동의 원인에 관한 연구)

  • 이성춘;김준호;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.94-99
    • /
    • 1994
  • 최근 인구의 과밀화와 이에 따른 지가의 상승 등으로 대표적인 주거용 빌딩인 아파트의 고층화가 급속하게 진행되고 있고 아파트에 설치되는 엘리베이터도 점차 대형화, 고속화 되고 있다. 실례로 15층 아파트의 경우 11인승, 60m/min의 엘리베이터가 일반적으로 사용되는 반면, 20층 아파트의 경우 17인승, 90m/min이 주로 사용된다. 이와 같이 엘리베이터의 용량과 운행 속도가 증가함에 따라 필연적으로 소음 및 진동 문제가 발생하게 된다. 특히 아파트의 경우 침실, 공부방 등 고도의 정숙을 요하는 생활 공간이 많고, 내부 공간의 활용도를 높이기 위하여 이들 방들이 엘리베이터 기계실 또는 운행 통로와 직접 접하여 있는 경우도 있어 이 경우 소음, 진동 문제는 아주 심각한 문제로 대두된다. 본 연구소가 측정한 방에 의하면 S신도시 L아파트의 경우 아파트 최상층 방에서 실내 소음도가 46dB(A), 벽의 진동가속도가 3.4mm/s$^{2}$(RMS)으로 나타났다. 진동의 경우 생활에 직접적인 악영향을 미칠 수준은 아니지만 소음의 경우 ASHRAE 권장 주택소음 기준치가 35dB(A) 이하임ㅇㄹ 감안하면 주거에 곤란한 수준이다. 수년전, 고층 아파트가 보급될 초기에는 아파트에 엘리베이터가 설치되어있다는 그 자체만으로 충분한 장점이 되어 다소음 소음, 진동문제는 큰 불만거리가 되지 않았지만 엘리베이터가 보편화된 지금에는 엘리베이터의 편리성만으로는 점점더 크게 요구되는 정숙성이 보상되지 않는다. 따라서 전반적인 아파트의 소음, 진동 문제에 큰 비중을 차지하는 엘리베이터에 의한 소음, 진동에 관하여 체계적인 연구가 필요하다. 이에 본고에서는 엘리베이터에 의한 아파트의 소음 및 진동에 관하여 그 현황, 원인 그리고 대책에 관한여 논하고자 한다.감 방법을 연구하였고, T.Sakai는 5자유도 모델을 이용하여 엔진 공회전시 발생하는 치타음에 대해 이론과 실험을 통해 해석하고, 엔진 회전수 변동, 클러치 특성, 변속기의 드래그(drag) 토크의 영향과 치타음 저감을 위한 개선된 클러치 특성을 제시하였다. 이 외에도 Thomas C.T.와 E.P.Petkus는 특정 차량에 대한 동력전달계의 비틀림 진동 현상에 대해 연구하였다. 이러한 연구들로 볼 때, 자동차 동력전달계에서 발생하는 진동은 이론과 실험을 통해 그 해석이 가능하며 설계에 매우 유용하게 이용되고 있음을 알 수 있다. 따라서, 본 연구는 4 실린더 4 싸이클 1.5 L 엔진을 장착한 경승용차의 실차 주행실험을 통해 가속 페달의 급조작에 따른 차체의 종진동 현상을 측정하고, 엔진-변속기-타이어-차체의 반환정계 4자유도 진동모델로 시뮬레이션을 수행하여 실차 주행실험의 결과치와 비교, 분석한 후 클러치 비틀림 특성을 비롯한 자동차 동력전달계의 각 설계인자들이 차체의 종진동에 어떠한 영향을 미치는가를 해석하고자 한다.be presented.LIFO, 우선 순위 방식등을 선택할 수 있도록 확장하였다. SIMPLE는 자료구조 및 프로그램이 공개되어 있으므로 프로그래머가 원하는 기능을 쉽게 추가할 수 있는 장점도 있다. 아울러 SMPLE에서 새로이 추가된 자료구조와 함수 및 설비제어 방식등을 활용하여 실제 중형급 시스템에 대한 시뮬레이션 구현과 시스템 분석의 예를 보인다._3$", chain segment, with the activation energy of carriers from the shallow trap with 0.4[eV], in he amorphous regions.의 증발산율은 우기의 기상자료를 이용하여 구한 결과 0.05 - 0.1

  • PDF

A Study on the Performance Evaluation and Field Application of Synthetic Resin Formwork (합성수지 거푸집의 성능평가 및 현장 적용성에 관한 연구)

  • Kim, Tae-Hui;Ahn, Sung-Jin;Lee, Young-Do;Nam, Kyung-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.577-584
    • /
    • 2018
  • In This study, length variation test, shock test, and noise test were conducted to evaluate the performance of synthetic resin form. In addition, the handling easiness of synthetic resin form was examined through field application. Results of both thermal length variation test and shock test satisfied the KS standards. for noise test, the result of uro-form was 106.7dB(A) in average while that of synthetic resin form was 100.4dB(A) in average. It is considered that the high sound pressure level of euro-form with this noise characteristic may have negative physical and psychological impact on people who are consistently exposed in the residential area. Finally, there was no warping or bulging of the mold during concrete placement in the field application. Also, the concrete surface finish of synthetic resin form was better than that of euro-form.

Vibration Estimation of Synchrotron Light Source Building Using Experimental Modal Analysis (실험적 모드해석을 이용한 방사광 가속기 건물의 진동평가)

  • 박상규;이홍기;권형오
    • Journal of KSNVE
    • /
    • v.5 no.3
    • /
    • pp.413-421
    • /
    • 1995
  • Synchrotron light source building of the accelerator has stringent vibration limits since the performance of the optical devices and electronic equipments in the laboratory is strongly influenced by the vibrations of the building. In this study, vibrations of the synchrotron light source building are estimated using experimental modal analysis and force response simulation technique. Dynamic properties of the building are identified from the modal parameters and vibration responses are predicted from the force response simulation. A double anti vibration system is designed and applied to the HVAC equipments and it has been shown that the measured vibrations of the building with the double anti vibration system satisfy the vibration criteria.

  • PDF

Design Procedure on the Environmental Effects of Compact Tower (컴팩트 타워 전기 환경장해 발생량에 따른 설계기법)

  • Lee, Won-Kyo;Park, Chan-Hyeong;Lee, Ho-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.557-558
    • /
    • 2011
  • 전력수요의 지속적 증가에 따라 송전설비의 추가 건설이 필요하지만 건설여건의 악화에 따라 보다 더 최적화된 송전철탑의 도입이 요구되고 있다. 이러한 문제를 해결하기 위한 방법으로 절연암을 채용한 철탑 설계 방법 및 기존 154kV 송전철탑을 활용하여 345kV 전압을 송전 할 수 있는 방안이 검토되고 있다. 송전전압이 높아지면 주변에 여러 가지 환경장해(코로나 소음, 통신선 유도 장해)를 유발하는데 이 장해 발생량은 철탑의 절연간격, 전력선의 종류 및 도체 구성방식에 따라 달라 된다. 따라서 기존 154kV 송전선로를 이용하여 345kV 송전 전압으로 격상을 위해서는 필수적으로 환경장해 유발 요인을 분석이 필요하고 환경장해를 최소화 할 수 있는 설계 기법이 요구된다. 이에 따라 본 논문에서는 기존 154kV 송전철탑을 이용하여 345kV 전압을 송전 할 때 환경장해 기준치를 만족하는 설계기법을 제시하고자 한다.

  • PDF

Indoor Environment Monitoring System (실내 환경 모니터링 시스템)

  • Kim, Bo-Ram;Park, Soo-Hyun;Hong, Bong-Hee
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06b
    • /
    • pp.57-59
    • /
    • 2012
  • 업무의 효율성을 증대하기 위해서는 주변 환경의 개선이 필요하다. 미국 냉난방 공조학회(ASHRAE)에서도 실내 환경이 업무에 미치는 영향을 발표하고 기준치를 제시했다. 이를 바탕으로 TES-1370, TES-1355센서를 이용하여 주변 환경의 '온도, 습도, co2, 소음'을 측정하고, 측정된 데이터를 가공하여 WEBPAGE와 MOBILE-WEBPAGE에서 차트와 함께 어디서든 쉽게 환경을 모니터링 할 수 있는 실내 환경 모니터링 시스템을 구축한다. 개발된 시스템으로 도서관과 강의실의 주변 환경을 모니터링을 했다.